Getinge Lancer Ultima labware washing systems Undercounter series This document is intended to provide information to an international audience outside of the US.

Open the catalog to page 1
Getinge Lancer Ultima labware washing systems - 2

High performance – compact footprint Getinge Lancer Ultima series washers offer the best labware cleaning solutions in the industry. From quality control to general laboratory research, Getinge Lancer Ultima series washers deliver high performance in a compact footprint. High density loading demands fewer cycles. Efficient use of water, detergents and rinsing agents minimizes the environmental impact. Energy saving construction lowers total cost of ownership. The exclusive Prolux programmable microprocessor controller commands a full range of prewash, wash, rinse and drying functions...

Open the catalog to page 2
Getinge Lancer Ultima labware washing systems - 3

Quiet operation Noise reduction design minimizes sound for quiet operation. Cool surface High-performance insulation contains heat and limits energy consumption. Prolux programmable microprocessor controller with intuitive touchscreen graphic user interface, alarm and monitoring, data capture and communications document cycle performance. Stainless steel top and bottom spray arms and two levels of injection washing ensure thorough spray coverage. Less noise, less surface heat and less space required Getinge Lancer Ultima series washers offer an ideal combination of precision engineering,...

Open the catalog to page 3
Getinge Lancer Ultima labware washing systems - 4

Three options, compact footprint 810 LX / 815 LX / 820 LX Drawings display top, front and side of unit, with door swing allowance. Drawings display top, front and side of unit, with door swing allowance. Exterior dimensions WxHxD Programs presets custom Rinse purified water Rinse acid Level sensors Net weight Water softener Forced-air chamber Forced-air chamber and injectors; HEPA filtered * Total water consumption per fill based on reservoir sump and all fluid path fill volumes, care should be taken when evaluating comparative water consumption claims. Site preparation 810 LX / 815 LX /...

Open the catalog to page 4
Getinge Lancer Ultima labware washing systems - 5

World class engineering – robust construction for safety and efficiency Ergonomic loading configurations • Telescoping load-bearing rails permit extension of racks for easy loading. All racks are interchangeable between top and bottom wash levels, and among Getinge Lancer Ultima series freestanding models 910 LX, 1300 LX and 1800 LXA. This minimizes the need for additional accessories. • The 3.5” high resolution touchscreen color display is easy to read from a distance and saves steps when monitoring. Upper rack removes easily without tools to accommodate tall labware loaded into the lower...

Open the catalog to page 5
Getinge Lancer Ultima labware washing systems - 6

One touch simplicity, limitless flexibility. Display screens Prolux controller The Prolux controller is based on a high-performance PLC microprocessor designed for simplicity, one-touch start, real-time status indicators and intuitive programming options that permit customization over the range of washer operations. Prolux integrates a suite of menu screens that support digital functions from cycle selection, process monitoring, warning advisories, audible and visual alarms, system communications and data capture. Select Program Programming Final rinse Select Program P01 Recycling...

Open the catalog to page 6
Getinge Lancer Ultima labware washing systems - 7

Comprehensive collection – a perfect fit for any lab Superior efficiency – for small and large needs. Getinge Lancer Ultima offers an expanded line of higher volume labware washers to improve throughput. Freestanding washers offer a range of performance features designed to deliver clean labware faster than other industrial washers. Freestanding washers are available in five configurations and five sizes to meet the demand for higher turnover of larger loads. Getinge Lancer Ultima means superior quality All models are produced to withstand harsh laboratory conditions, minimize water...

Open the catalog to page 7
Getinge Lancer Ultima labware washing systems - 8

Bioreactor preparation solution Enhancements for your unique application The expertise of Getinge and Applikon research and development has established a synergistic process for bioreactor preparation. – consistent processes deliver repeatable results A solution to prevent cross-contamination, minimize any research downtime and ensure validated outcome through optimal processes and procedures. Getinge offers a specially designed bioreactor wash rack for Getinge Lancer Ultima laboratory washers. This dedicated wash rack, for the multi-use bioreactors, establishes a highly reproducible system...

Open the catalog to page 8
Getinge Lancer Ultima labware washing systems - 9

Common accessories Choose from up to 60 different injector racks, pipette racks and baskets. All racks are interchangeable between the washer lower and upper levels. 518 • A wide variety of standard inventory baskets and injector racks are available to meet most needs. • Custom racks and baskets can be fabricated to meet specific needs or special applications. Basic basket with reversible tray lid: Catalog No. PST and GC Basic basket with spray arm: Catalog No. PSBT Basket for culture dishes: Catalog No. BP Baskets Useful for beakers, trays, dishes, dissolution vessels, funnels, instruments...

Open the catalog to page 9
Getinge Lancer Ultima labware washing systems - 10

Short injectors, 76 mm (3”) tall For inside out cleaning of narrow neck glassware, bottles, cylinders, boiling flasks, Erlenmeyer flasks and volumetric flasks. Part number Half rack, 27 short jets, 6 mm diameter 36 short jets, 6 mm diameter 41 short jets, 6 mm BOD rack 48 short jets, 2 mm diameter 48 short jets, 6 mm diameter 64 short jets, 2 mm diameter 64 short jets, 6 mm diameter 64 short jets, mixed 2 mm and 6 mm diameter 100 short jets, mixed 2 mm and 6 mm diameter 100 short jets, 6 mm diameter 100 short jets, 2 mm diameter IXC: Injector rack, short injectors, 76 mm (3") tall, jets 6...

Open the catalog to page 10
Getinge Lancer Ultima labware washing systems - 11

Long injectors For inside out cleaning of large narrow neck glassware, bottles, cylinders, boiling flasks, Erlenmeyer flasks and volumetric flasks. Part number 5 long jets, 12.7 mm diameter, with spray ball 9 long jets, 12 mm diameter 12 long jets, 8 mm diameter 20 long jets, 8 mm diameter 36 long jets, 6 mm diameter 48 long jets, 6 mm diameter 64 long jets, 6 mm diameter Adjustable clip positions labware on injector for optimal cleaning performance. 100 long jets, 6 mm diameter