video corpo

GEZE Sliding, Telescopic and Folding door systems
92Pages

{{requestButtons}}

Catalog excerpts

GEZE Sliding, Telescopic and Folding door systems - 1

GEZE SLIDING, TELESCOPIC AND FOLDING DOOR SYSTEMS VERSATILE AND COMFORTABLE

Open the catalog to page 1
GEZE Sliding, Telescopic and Folding door systems - 2

Cover photo: Tarık Kaan Muşlu, photo on page 2: Siegelwerk GmbH

Open the catalog to page 2
GEZE Sliding, Telescopic and Folding door systems - 3

Automatic sliding door systems GEZE SLIDING, TELESCOPIC AND FOLDING DOORS Foreword: GEZE sliding door systems 4 Automatic sliding door systems Automatic sliding doors (standard) 6 Redundant sliding doors for emergency exit routes (FR) 7 Redundant sliding doors for locked emergency exit routes (FR-RWS) 7 Redundant sliding doors for emergency exit routes with locked shop closing function (FR-LL) 8 Redundant sliding doors for emergency exit routes in both directions (FR-DUO) 8 Sliding doors for emergency exit routes with break-out function (BO) 9 Sliding doors for emergency exit routes...

Open the catalog to page 3
GEZE Sliding, Telescopic and Folding door systems - 4

Automatic sliding door systems GEZE SLIDING, TELESCOPIC AND FOLDING DOORS GEZE sliding door systems For comfort and perfection Sliding doors are space-saving, elegant and modern. Glass sliding doors are ideal when it comes to making good use of daylight and fulfilling optical criteria. Automatic sliding doors from GEZE can be used to implement the widest range of application requirements within a building. The variations in the Slimdrive drive series, having an overall height of only seven centimetres, fit perfectly into any building’s architecture and offer a wide range of application...

Open the catalog to page 4
GEZE Sliding, Telescopic and Folding door systems - 5

Automatic sliding door systems GEZE SLIDING, TELESCOPIC AND FOLDING DOORS Overview table for automatic sliding door systems Product features Dimensions (height x depth) Opening / closing speed (max.) Automatic sliding doors (standard) Emergency exit routes (FR) FR with locked shop closing (FR-LL) FR in both directions (FR-DUO) Corner sliding doors (SLV) Inclined sliding doors (SL inclined) Fitting ISO-glass fine-framed MONO-glass fine-framed ESG clamping profile All-glass system (GGS) Integrated all-glass system (IGG) Stainless steel On-site leaves * = max. 160 kg for FR variation, max. 120...

Open the catalog to page 5
GEZE Sliding, Telescopic and Folding door systems - 6

Automatic sliding door systems GEZE SLIDING, TELESCOPIC AND FOLDING DOORS Automatic sliding doors (standard) Variety and safety Automatic sliding door drives in particular often have to meet above-average demands in terms of functionality and economy. GEZE sliding door systems are suitable for universal use. Automatic sliding doors from GEZE can be realised with the following drive series: Slimdrive, ECdrive and Powerdrive. Standard sliding door Augustinum, Stuttgart, Germany (Photo: Dirk Wilhelmy) Application range Public buildings and authorities Businesses and car dealerships Shopping...

Open the catalog to page 6
GEZE Sliding, Telescopic and Folding door systems - 7

Automatic sliding door systems GEZE SLIDING, TELESCOPIC AND FOLDING DOORS Redundant sliding doors for emergency exit routes (FR) Function maintained in the event of a power failure thanks to several different drive components To guarantee the safety of emergency escape routes, extra redundant components are integrated into the complete system. This redundancy guarantees that in the event of a power failure or fault, the sliding door will automatically open safely in the operating modes “Automatic” and “Shop closing”. In the operating mode “Night” the locking system prevents unauthorised...

Open the catalog to page 7
GEZE Sliding, Telescopic and Folding door systems - 8

Automatic sliding door systems GEZE SLIDING, TELESCOPIC AND FOLDING DOORS Redundant sliding doors for emergency exit routes with locked shop closing function (FR-LL) Protected against forced opening from the outside through permanent locking with duplicate processing This GEZE solution allows door systems on emergency escape routes that are set in the operating mode „Shop closing“ (one-way) to be locked via the intelligent control and monitored locking system. This increases the protection of the door against unauthorised opening from the outside. This type-tested FR-LL variation is ideal...

Open the catalog to page 8
GEZE Sliding, Telescopic and Folding door systems - 9

Automatic sliding door systems GEZE SLIDING, TELESCOPIC AND FOLDING DOORS Sliding doors for emergency exit routes with break-out function (BO) Emergency opening by pivoting leaves and sides open GEZE sliding doors with break-out function are used on emergency escape routes. The BO function allows the leaves to be pivoted open in the direction of escape – as a sliding door system with a swing fitting, so to speak. Sliding doors with BO function have pivoted side parts and are available for 1 or 2-leaf door systems. Doors with escape route requirements are used in regions where redundant...

Open the catalog to page 9
GEZE Sliding, Telescopic and Folding door systems - 10

Automatic sliding door systems GEZE SLIDING, TELESCOPIC AND FOLDING DOORS Sliding doors with burglar resistance in accordance with resistance class 2 (RC 2) Special protection from burglary and vandalism The burglar-resistant automatic linear sliding door system GEZE Slimdrive SL RC 2 and the emergency exit route variation SL-FR RC 2 makes burglars’ lives difficult. It was specially developed for building entrances with increased security requirements. Both variations have been tested according to component resistance class 2 (RC 2) in line with DIN V ENV 1627 to 1630. This means that they...

Open the catalog to page 10
GEZE Sliding, Telescopic and Folding door systems - 11

Automatic sliding door systems GEZE SLIDING, TELESCOPIC AND FOLDING DOORS Fire protection sliding doors (T30) With hold-open and release device, permanent closing in the event of a fire Fire protection doors are used to stop fire getting through wall openings in fire-retardant walls. Fire protection doors of resistance class T30 are fire-retardant doors according to DIN 4102 and smoke-proof according to DIN 18095. The closing function is guaranteed in the event of a fire too. After the fire alarm has been raised and/or the mains supply voltage has failed, the door automatically closes by...

Open the catalog to page 11
GEZE Sliding, Telescopic and Folding door systems - 12

Automatic sliding door systems GEZE SLIDING, TELESCOPIC AND FOLDING DOORS Folding doors (SF) Versatility for optimum use of space Wherever maximum passage widths must be achieved in tight spaces, the use of automatic doors with horizontal folding door leaves is the optimum solution. The GEZE automatic folding door system, with the 7 cm drive height characteristic of the Slimdrive series, guarantees maximum passage height for conversions, for example. The low overall height of the drive makes it almost unnoticeable, yet it is highly efficient. Retrofitting to existing facades is no problem....

Open the catalog to page 12

All GEZE catalogs and technical brochures