Gigahertz-OptikP-9710 http://www.gigahertz-optik.de/en-us/product/P-9710Product tags: Dosimeter Gigahertz-Optik GmbH
Open the catalog to page 1P-9710-1 - Multi-functional light meter for high-quality photometric measurements The P-9710-1 optometer is a high-quality device designed by Gigahertz-Optik for mobile use. Its signal amplifier provides a wide dynamic range for the detectors' signal currents ranging up to 2 mA. The noise-equivalent current signal is as low as 0.1 pA. The device has eight gain ranges that can be manually or automatically selected for adjustment to match the signal levels. Variable integration time One of the characteristic properties of the P-9710-1 optometer is the short integration time of the input amplifier...
Open the catalog to page 2The P-9710-1 optometer has eighteen different measurement modes that can easily be selected using a user-friendly menu hence enabling its multifunctional application. P-9710-2 - Optometer for dose measurement of short pulses using the pulse stretching method Unlike the P-9710-1, the P-9710-2 optometer has a 20 ms standard time constant in all eight gain ranges. Thus light pulses shorter than 1 ns are stretched to 20 ms. The pulse energy of the stretched pulse can then be measured precisely with the 100 ps sample rate of the optometer. P-9710-4 - multi-functional light meter for synchronized measurement...
Open the catalog to page 3Gigahertz-Optik GmbH
Open the catalog to page 4Product Description Show productImage VL-3701 Detector head for the measurement of photopic illuminance in Lux [lx]. Features: f1 < 3 %, f2 < 1.5 %, 0.5 nA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate Gigahertz-Optik GmbH
Open the catalog to page 5Product Image Show product Detector head to measure the photopic spot luminance in cd/m2. http://www.gigahert7-o ptik.de/en-Features: 1.1° viewing angle, simple to use, very low stray light, us/product/IDM-9901 for the usage with Optometers and amplifiers, calibration certificate. High sensitive detector head to measure the photopic luminance in cd/m2. Features: front lense for 1°, 2°, 5° or 10° viewing angle, for the usage with Optometers and amplifiers, calibration certificate Gigahertz-Optik GmbH
Open the catalog to page 6Product Image Show product Integrating sphere detector for luminous flux (lm) of 2π sources. Features: 300mm dia, BaSO4 coating, 101,6mm dia port, for the usage with optometers and signal amplifiers, Calibration certificate Integrating sphere detector for luminous flux (lm) of 2π sources. Features: 500mm dia, BaSO4 coating, 127mm dia port, for the usage with optometers and signal amplifiers, Calibration certificate Integrating sphere detector for luminous flux (lm) of 2π and 4π sources. Features: 500mm dia, BaSO4 coating, sphere to open, auxiliary lamp, for the usage with optometers and signal...
Open the catalog to page 7Product Description Show product Detector head for the measurement of irradiance in W/m2. Features: spectral responsivity from 400-500nm (BLUE), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate. Detector head for the measurement of irradiance in W/m2. Features: spectral responsivity from 700-800nm (RED), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate. Detector head for high intensity irradiation in UV or blue light http://www.gigahertz-o curing processes. ptik.de/en- us/product/RCH-1 Features: Separate light...
Open the catalog to page 8Product Image Show product Integrating sphere detector for radiant power in W of 2π sources. Features: 400 nm - 1100 nm radiometric responsivity, 50 mm dia, 12.5 mm dia port, for the usage with optometers and signal amplifiers, Calibration certificate Detector head to measure low intensity LASER radiant power in W. Features: 11.28mm dia (1cm²) active area, 400 to 1100nm, for the usage with optometers and signal amplifiers, calibration certificate. Integrating sphere detector with short rise time for Laser power in W. Features: 8 mm dia, ODM98 coating, 400 nm - 1100 nm responsivity, optional SMA...
Open the catalog to page 9Product Image Show product Integrating sphere detector for Laser power in W. http://www.gigahert7-o ptik.de/en-Features: 50 mm dia, 10 mm dia port, synthetic ODM98 coating, us/product/ISD-5P-Si 400 nm - 1100 nm responsivity, for the usage with optometers and signal amplifiers, Calibration certificate Integrating sphere detector for Laser power in W. Features: 100mm dia, 15mm dia port, BaSO4 coating, 400-1100nm responsivity, for the usage with optometers and signal amplifiers, Calibration certificate Gigahertz-Optik GmbH
Open the catalog to page 10Product Image Show product Detector head for plant growth. Features: 590-900nm photomorphogenesis actinic irradiance, for use with optometers, calibration certificate. Gigahertz-Optik GmbH
Open the catalog to page 11Product Description Show productImage UV-3702 Detector head for the measurement of irradiance of UV radiation in W/m2. Features: spectral responsivity from 280-315nm (UV-B), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate. Gigahertz-Optik GmbH
Open the catalog to page 12Product Description Show productImage UV-3721 Detector head for the measurement of irradiance of UV radiation in W/m2. Features: spectral responsivity from 350-400nm (UV-A), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate. Gigahertz-Optik GmbH
Open the catalog to page 13Product Image Show product Detector for Blue-light and retinal thermal hazard of expanded light sources. Features: 1.7mrad, 11mrad and 100mrad field-of-view. view finder, focusable, for the usage with Optometers, calibration certificate. Purchasing information Article-Nr Gigahertz-Optik GmbH
Open the catalog to page 14Gigahertz-Optik GmbH
Open the catalog to page 156 Pages
6 Pages
11 Pages
3 Pages
3 Pages
4 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
4 Pages
10 Pages
9 Pages
5 Pages
4 Pages
3 Pages
10 Pages
16 Pages