UPB-150-ARTA

UPB-150-ARTA
1 / 10 PagesView full catalog

UPB-150-ARTA

Product catalog summary
Description: The UPB-150-ARTA is an integrating sphere photometer designed for determining optical material properties such as reflection, transmission, and absorption. It is commonly used in both broadband and narrowband photometric applications.
Specifications: The sphere has a diameter of 150 mm and is coated with barium sulfate (ODP97) for diffuse reflectivity across a spectral range of 300 nm to 2500 nm. It features five measurement ports with a 30 mm diameter and knife-edge design for high acceptance angles.
Features: The UPB-150-ARTA offers multifunctionality with its five knife-edged measurement ports, which can be used open or closed. It includes a sample holder for cuvettes and sample glasses, allowing for various measurement setups such as absorption, photoluminescence, and luminous flux measurements.
Accessories: The system includes port plugs, port reducers, and a Slide & Fix holder for easy attachment and removal. A light trap with a 30 mm input port minimizes back reflection, and quick-change holders are available for detectors and light guides.
Applications: Typical applications include spectrophotometry and other transmission, reflection, and absorption measurement setups. The sphere is equipped with a revolving sample holder for cuvettes and plate samples, and it supports measurements of organic electroluminescence.
Miscellaneous: The UPB-150-ARTA is mounted on a bench-top stand with a base plate and weighs approximately 1.1 kg. It is available with various accessories for enhanced functionality.
See more

Catalog excerpts

UPB-150-ARTA-1

Gigahertz-OptikUPB-150-ARTA http://www.gigahertz-optik.de/en-us/product/UPB-150-ARTAProduct tags: Gigahertz-Optik GmbH

 Open the catalog to page 1
UPB-150-ARTA-2

Description Photometry to determine optical material properties Optical material properties is a general term used to refer to the reflection, transmission and absorption properties of a material. Photometry hereby refers to a measurement process through which material properties as well as photometric measurands are determined using a photometer. Integrating sphere photometer The integrating sphere is very common in both broadband and narrowband photometric applications for diffuse sample illumination and detection of the reflected and transmitted light proportions. UPB-150-ARTA multi-port integrating...

 Open the catalog to page 2
UPB-150-ARTA-3

reducers and a light trap. Light trap with Slide & Fix holder The UPB-150-ARTA is fitted with a revolving sample holder for cuvette and plate samples for absorbance measurement applications. The light trap has a 30mm input port and ensures minimal back reflection over the entire usable spectral range of the integrating sphere through its internal design and black absorbing coating. The Slide & Fix holder can be used to combine the light trap with port reducers and the sample holder. Quick-change holder for detectors and light guides Removable adapters are offered for mounting of detectors and...

 Open the catalog to page 3
UPB-150-ARTA-4

Typical spectral reflection of the sphere coating made of barium sulfate (ODP97). UPB-150-ARTA, base sphere with stand UPB-150-ARTA-Z01, detector port adapter with baffle aligned to the sphere center. UMPF-0.5 port frame UPB-150-ARTA-Z03, revolving base for the cuvette and clamp sample holder Gigahertz-Optik GmbH

 Open the catalog to page 4
UPB-150-ARTA-5

UPB-150-ARTA-Z04, cuvette holder. Hollow post UPB-150-ARTA-Z05, clamp holder for test glass and foils. Hollow post UPB-150-ARTA-Z06, plug for the upper sphere port. Spherical plug shape UPB-150-ART-Z01, port plug with flat surface Gigahertz-Optik GmbH

 Open the catalog to page 5
UPB-150-ARTA-6

Gigahertz-Optik GmbH

 Open the catalog to page 6
UPB-150-ARTA-7

UPB-150-ART-Z05, 0.5“ detector mount with baffle UPB-150-ART-Z06, 1.0“ detector mount with baffle UPB-150-ART-Z07, 2.0“ detector mount with baffle Gigahertz-Optik GmbH

 Open the catalog to page 7
UPB-150-ARTA-8

UPB-150-ART-Z09, port plug with spherical surface UPB-150-ART-Z10, port reducer with spherical surface. Free diameter as specified Gigahertz-Optik GmbH

 Open the catalog to page 8
UPB-150-ARTA-9

Purchasing information Article-Nr Gigahertz-Optik GmbH

 Open the catalog to page 9
UPB-150-ARTA-10

Gigahertz-Optik GmbH

 Open the catalog to page 10

All Gigahertz-Optik catalogs and technical brochures

  1. X1-4

    6  Pages

  2. X1-3

    6  Pages

  3. X1

    11  Pages

  4. BN-Rxx-D2

    3  Pages

  5. BN-LDSF-2P

    3  Pages

  6. BN-1501

    4  Pages

  7. VL-1101

    5  Pages

  8. UV-3725

    5  Pages

  9. UV-3717

    5  Pages

  10. UV-3711

    5  Pages

  11. UV-3710

    5  Pages

  12. BTS-Solar

    4  Pages

  13. UPB-150-ART

    9  Pages

  14. TPI21-TH

    5  Pages

  15. TFCT25

    4  Pages

  16. X1-RM

    10  Pages

  17. P-2000

    16  Pages

  18. P-9710

    15  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.