Gigahertz-OptikX1-4 http://www.gigahertz-optik.de/en-us/product/X14Product tags: UV Gigahertz-Optik GmbH
Open the catalog to page 1European Commission UV Protection Directive UV radiation is one of the most prevalent cancer risk factors. Because of this, federal lawmakers are trying to reduce the risk from artificial UV radiation with the UV Protection Directive. For sun tanning beds that emit UV radiation, this is achieved by a limit on the maximum UV output. UV Erythema Broadband Radiometer In order to provide the responsible committees with a mobile instrument to measure UV radiation in accordance with the UV Protection Directive, Gigahertz-Optik GmbH has developed the X14 Broadband Radiometer. UVA and UVB Two-channel...
Open the catalog to page 2Threshold values irradiance UV Protection Directive 60335-2-27 5050-1 Threshold values spectral correction UV Protection Directive 60335-2-27 5050-1 Threshold value cosine correction UV Protection Directive 60335-2-27 5050-1 Consult 60335-2-27 and 5050-1 No value for spectral correction f1< 0.2 for broadband radiometer spectrum head with additional UVC radiation detection function Consult 60335-2-27and 5050-1 No specifications for difference to cosine f2 <0 .06 for broadband radiometer Threshold value temperature coefficient UV Protection Directive 60335-2-27 5050-1 Burn-in period of UV Emitters...
Open the catalog to page 3Main features Compact gauge in ergonomic design for one hand control. Three-chanel detector head XD-45-ERYC for the measurement of the effective UV-A and UV-BC Erythema irradiance and detection of UV-C irradiance. Battery powered with two AA cells. USB-Interface. Measurement range In accordance with the specifications of the detector head XD-45-ERYC. typical applications Mobile gauge for the check of the Erythem risk by use of sunbeds and tanning beds. Meter: Calibration and comparison of the current responsivity in each of the seven gain ranges. Detector heads: Calibration of the actinic responsivity...
Open the catalog to page 4f2 (directional response/cosine error) spectral responsivity Product Description Show productImage XD-45-ERYC Detector for UV hazard measurements of solaria and other tanning lamps in accordance to UVSV. Features: Multi-cell detector for ERYTHEMA effective irradiance and UV-C evidence, for the usage with X1-4 optometer, calibration certificate. Gigahertz-Optik GmbH
Open the catalog to page 5Gigahertz-Optik GmbH
Open the catalog to page 66 Pages