Radiotherapy Patient System RPS head - Technical data Adjustable head support for Radiotherapy Cancer Treatments RPS head 3 DoF rotational error correction improves brain SRS/SRT treatments Description and essential performance features of the adjustable head support Stereotactic radiation therapy becomes more and more frequent. Recently, the simultaneous treatment of multiple brain metastases using a single isocenter is to become a standard. Accurate delivery of stereotactic treatment techniques requires - besides the translational positioning - exact rotational alignment with the planning CT. This positioning is normally supported by a 6D robotic couch. As many Linacs are equipped with couches that are restricted to translational movements only, those would benefit from a head immobilization system with adjustable rotations (X, Y and Z). The RPS head allows sub-millimetric patient positioning accuracy in three degrees of freedom (3 DoF), improving clinical workflow and patient confidence. 3 DoF means that the system can correct rotational errors (X, Y and Z). RPS head SGRT The simplest way of using RPS head is in combination with a surface scanner (e.g., C-RAD Catalyst). The rotational positioning error values detected by the surface scanner can be directly and easily corrected with the RPS head device. The correct patient position can be verified via live scanner data. RPS head CBCT RPS head CBCT includes a standalone software with GUI. This calculation tool takes positional 6D error values detected by a CBCT (e.g. Elekta XVI) as input and converts it. The three new rotational values are corrected by using RPS head and the three new translational error values are corrected via base table shifts. A rotatable head support plate is fixed by a ball joint, placed near the neck, to a base frame beneath the patient. The head support plate immobilizes the head of a patient with the aid of a thermoplastic mask (3rd party). The adjustment mechanism is placed near the patient’s head. Care was taken to minimize the size of the operating housing in order not to spoil non-coplanar beams. The angles are manually adjustable via three individual star knobs. gKteso GmbH Technologies & Solutions Copyright by gKteso GmbH 2021
Open the catalog to page 1Radiotherapy Patient System RPS head - Technical data The RPS head device is intended to support rotational positioning error corrections of a patient head prior to a radiotherapy cancer treatment. Rotational error correction is possible in all three axes individually within the range of up to +/- 4.0 degrees by adjusting related knobs manually on the device. The device is to be used by radiation therapists. Before rotational error correction and subsequent treatment, the patient’s head is immobilized by a thermoplastic mask (which is not part of the RPS head device). Scientific References: -...
Open the catalog to page 22 Pages