Drilling Protocol (Ø3.0 x 11.5 mm) RECOMMENDED DRILLING SPEEDS Twist/Shaping Drills: 800-1200 RPM Screw Tap: Do not exceed 25 RPM Final Drill Twist Drill Ø2.8/2.4 x 11.5 mm Optional Dense Bone Screw Tap Ø3.0 mm Implant Driver Ø3.0 Long Hahn™ Tapered Implant Ø3.0 x 11.5 mm Ensure all surgical instruments are available prior to surgery. Osteotomy depth may be increased sequentially, beginning with shorter drill lengths, provided sufficient depth is achieved with the final drill. Do not use any drill that exceeds the diameter or length of the prescribed
Open the catalog to page 1Implant Driver Ø3.0 Long
Open the catalog to page 2Drilling Protocol (Ø3.0 x 13 mm) RECOMMENDED DRILLING SPEEDS Twist/Shaping Drills: 800-1200 RPM Screw Tap: Do not exceed 25 RPM Final Drill Twist Drill Ø2.8/2.4 x 13 mm Optional Dense Bone Screw Tap Ø3.0 mm Implant Driver Ø3.0 Long Hahn™ Tapered Implant Ø3.0 x 13 mm Ensure all surgical instruments are available prior to surgery. Osteotomy depth may be increased sequentially, beginning with shorter drill lengths, provided sufficient depth is achieved with the final drill. Do not use any drill that exceeds the diameter or length of the prescribed
Open the catalog to page 3Implant Driver Ø3.0 Long
Open the catalog to page 4Drilling Protocol (Ø3.0 x 16 mm) RECOMMENDED DRILLING SPEEDS Twist/Shaping Drills: 800-1200 RPM Screw Tap: Do not exceed 25 RPM Final Drill Twist Drill Ø2.8/2.4 x 16 mm Optional Dense Bone Screw Tap Ø3.0 mm Implant Driver Ø3.0 Long Hahn™ Tapered Implant Ø3.0 x 16 mm Ensure all surgical instruments are available prior to surgery. Osteotomy depth may be increased sequentially, beginning with shorter drill lengths, provided sufficient depth is achieved with the final drill. Do not use any drill that exceeds the diameter or length of the prescribed
Open the catalog to page 5Implant Driver Ø3.0 Long
Open the catalog to page 6Drilling Protocol (Ø3.5 x 8 mm) RECOMMENDED DRILLING SPEEDS Twist/Shaping Drills: 800-1200 RPM Screw Tap: Do not exceed 25 RPM Final Drill Shaping Drill Ø3.5 x 8 mm Optional Dense Bone Screw Tap Ø3.5 mm Implant Driver Ø3.5/4.3 Long/Short Hahn™ Tapered Implant Ø3.5 x 8 mm Ensure all surgical instruments are available prior to surgery. Osteotomy depth may be increased sequentially, beginning with shorter drill lengths, provided sufficient depth is achieved with the final drill. Do not use any drill that exceeds the diameter or length of the prescribed
Open the catalog to page 7Implant Driver Ø3.5/4.3 Long Implant Driver Ø3.5/4.3 Short
Open the catalog to page 8Drilling Protocol (Ø3.5 x 10 mm) RECOMMENDED DRILLING SPEEDS Twist/Shaping Drills: 800-1200 RPM Screw Tap: Do not exceed 25 RPM Final Drill Shaping Drill Ø3.5 x 10 mm Optional Dense Bone Screw Tap Ø3.5 mm Implant Driver Ø3.5/4.3 Long/Short Hahn™ Tapered Implant Ø3.5 x 10 mm Ensure all surgical instruments are available prior to surgery. Osteotomy depth may be increased sequentially, beginning with shorter drill lengths, provided sufficient depth is achieved with the final drill. Do not use any drill that exceeds the diameter or length of the prescribed
Open the catalog to page 9Implant Driver Ø3.5/4.3 Long Implant Driver Ø3.5/4.3 Short
Open the catalog to page 10Drilling Protocol (Ø3.5 x 11.5 mm) RECOMMENDED DRILLING SPEEDS Twist/Shaping Drills: 800-1200 RPM Screw Tap: Do not exceed 25 RPM Twist Drill Twist Drill Ø2.4/1.5 mm Ø2.8/2.4 x 11.5 mm Final Drill Shaping Drill Ø3.5 x 11.5 mm Optional Dense Bone Screw Tap Ø3.5 mm Implant Driver Ø3.5/4.3 Long/Short Hahn™ Tapered Implant Ø3.5 x 11.5 mm Ensure all surgical instruments are available prior to surgery. Osteotomy depth may be increased sequentially, beginning with shorter drill lengths, provided sufficient depth is achieved with the final drill. Do not use any drill that exceeds the diameter or...
Open the catalog to page 11Implant Driver Ø3.5/4.3 Long Implant Driver Ø3.5/4.3 Short
Open the catalog to page 12Drilling Protocol (Ø3.5 x 13 mm) RECOMMENDED DRILLING SPEEDS Twist/Shaping Drills: 800-1200 RPM Screw Tap: Do not exceed 25 RPM Final Drill Shaping Drill Ø3.5 x 13 mm Optional Dense Bone Screw Tap Ø3.5 mm Implant Driver Ø3.5/4.3 Long/Short Hahn™ Tapered Implant Ø3.5 x 13 mm Ensure all surgical instruments are available prior to surgery. Osteotomy depth may be increased sequentially, beginning with shorter drill lengths, provided sufficient depth is achieved with the final drill. Do not use any drill that exceeds the diameter or length of the prescribed
Open the catalog to page 13Implant Driver Ø3.5/4.3 Long Implant Driver Ø3.5/4.3 Short
Open the catalog to page 14Drilling Protocol (Ø3.5 x 16 mm) RECOMMENDED DRILLING SPEEDS Twist/Shaping Drills: 800-1200 RPM Screw Tap: Do not exceed 25 RPM Final Drill Shaping Drill Ø3.5 x 16 mm Optional Dense Bone Screw Tap Ø3.5 mm Implant Driver Ø3.5/4.3 Long/Short Hahn™ Tapered Implant Ø3.5 x 16 mm Ensure all surgical instruments are available prior to surgery. Osteotomy depth may be increased sequentially, beginning with shorter drill lengths, provided sufficient depth is achieved with the final drill. Do not use any drill that exceeds the diameter or length of the prescribed
Open the catalog to page 15Implant Driver Ø3.5/4.3 Long Implant Driver Ø3.5/4.3 Short
Open the catalog to page 16Drilling Protocol (Ø4.3 x 8 mm) RECOMMENDED DRILLING SPEEDS Twist/Shaping Drills: 800-1200 RPM Screw Tap: Do not exceed 25 RPM Final Drill Shaping Drill Ø4.3 x 8 mm Optional Dense Bone Screw Tap Ø4.3 mm Implant Driver Ø3.5/4.3 Long/Short Hahn™ Tapered Implant Ø4.3 x 8 mm Ensure all surgical instruments are available prior to surgery. Osteotomy depth may be increased sequentially, beginning with shorter drill lengths, provided sufficient depth is achieved with the final drill. Do not use any drill that exceeds the diameter or length of the prescribe
Open the catalog to page 17Implant Driver Ø3.5/4.3 Long Implant Driver Ø3.5/4.3 Short
Open the catalog to page 18Drilling Protocol (Ø4.3 x 10 mm) RECOMMENDED DRILLING SPEEDS Twist/Shaping Drills: 800-1200 RPM Screw Tap: Do not exceed 25 RPM Final Drill Shaping Drill Ø4.3 x 10 mm Optional Dense Bone Screw Tap Ø4.3 mm Implant Driver Ø3.5/4.3 Long/Short Hahn™ Tapered Implant Ø4.3 x 10 mm Ensure all surgical instruments are available prior to surgery. Osteotomy depth may be increased sequentially, beginning with shorter drill lengths, provided sufficient depth is achieved with the final drill. Do not use any drill that exceeds the diameter or length of the prescribe
Open the catalog to page 19All Glidewell Direct catalogs and technical brochures
-
MSDS Capture Impression
1 Pages
-
glidewell.io™ In-Office Solution
12 Pages
-
INTRAORAL SCANNER
2 Pages
-
Erkodur-S
4 Pages