Global D Therapeutic arsenal - Surgery
25Pages

{{requestButtons}}

Catalog excerpts

Global D Therapeutic arsenal - Surgery - 1

Global D Therapeutic arsenal twinkon® 4 In-Kone®UNIVERSAL In-Kone®PRIMO 3.0 implant Implants with subcrestal shoulder Surgery Partner for your surgery

Open the catalog to page 1
Global D Therapeutic arsenal - Surgery - 2

Global D therapeutic arsenal Implants with subcrestal shoulder Surgery Overview of the Global D therapeutic arsenal Implants In-Kone® UNIVERSAL In-Kone® PRIMO 3.0 implant twinkon® 4 Healing screws In-Kone® system 3.0 implant system twinkon® 4 system Technical information TA6V ELI, the material of choice for implantology The prosthetic connection at the heart of the implantable device Surgical kits ULTIMATE surgical kit (can be extended for 3.0 implant) Surgical kit specifically for 3.0 implant Surgical kit specifically for twinkon® 4 Pre-implant surgery Partner for your surgery Graft screws...

Open the catalog to page 2
Global D Therapeutic arsenal - Surgery - 3

Overview of the Global D therapeutic arsenal Implants with subcrestal shoulder Traditional platform-switching 4.8 mm The range of implants with subcrestal shoulder has been designed to promote a lasting response in terms of protection of the peri-implant tissues in most clinical situations. Peri-implant trophicity is optimised in comparison with conventional implantology: the bone table is wider, the volume of the peripheral conjunctive tissue is thicker and the management of the emergence profile is more harmonious. Subcrestal shoulder Implants and surgical kits Implant performance High...

Open the catalog to page 3
Global D Therapeutic arsenal - Surgery - 4

In-Kone® UNIVERSAL Presentation The In-Kone® UNIVERSAL is a 2-piece implant with a roughened subcrestal shoulder which encourages bone crimping of the collar during osseointegration. When used with the slim, concave profiles of the prosthetic components, the bone table obtained promotes stabilisation of a thick protective mucosal-conjunctive seal. The tight anti-bacterial seal and prosthetic immobility of the connection of In-Kone® UNIVERSAL implants are two essential factors for preserving the amount of peri-implant tissue over time. The In-Kone® UNIVERSAL is a therapeutic solution which is...

Open the catalog to page 4
Global D Therapeutic arsenal - Surgery - 5

In-Kone® PRIMO Presentation The In-Kone® PRIMO is a 2-piece implant with a roughened subcrestal shoulder which encourages bone crimping of the collar during osseointegration. When used with the slim, concave profiles of the prosthetic components, the bone table obtained promotes stabilisation of a thick protective mucosalconjunctive seal. The tight anti-bacterial seal and prosthetic immobility of the connection of In-Kone® PRIMO implants are two essential factors for preserving the amount of peri-implant tissue over time. The In-Kone® PRIMO is a therapeutic solution which is particularly...

Open the catalog to page 5
Global D Therapeutic arsenal - Surgery - 6

The 3.0 implant is a 2-piece implant indicated for narrow interdental spaces in the incisor area. The implant has a roughened subcrestal shoulder which encourages bone crimping of the collar and helps preserve the amount of periimplant tissue. The prosthetic components are assembled using the ActiLock® concept: this is an innovative concept which provides a stable hermetic seal, ensuring that the components are gently locked in the mouth by the “Morse” effect. Acti-Lock® is simple to use, shock-free and atraumatic for the patient, and is easy to reverse if necessary, using an extractor. The...

Open the catalog to page 6
Global D Therapeutic arsenal - Surgery - 7

The twinkon 4 is a 4 mm long ultra-short implant which can be used in 1-stage surgery. The implant is available in two diameters: 4 mm and 4.5 mm. It has been designed to provide an effective response to 4 major requirements: Immediate primary stability and rapid osseointegration The formation of a thick protective mucosal seal which helps to preserve the residual bone mass An effective prosthetic connection capable of providing an effective periodontal and mechanical response Can be used with a safe, reproducible surgical protocol ® INDICATION: With one implant per missing tooth, the...

Open the catalog to page 7
Global D Therapeutic arsenal - Surgery - 8

In-Kone® healing screw Main principles of the In-Kone® prosthesis Healing screw references PRIMO “Tall” screw ‘‘Flat” screw Common prosthesis range Single connection to 3.5/4/4.5/5 mm diameters Periodontal height Signature of the emergence profile 1. A signature suitable for the tissue profiles Tension-free healing screw Concave aesthetic emergence profiles 2. Colour code and laser marking on the screw heads Note: The healing screws and cover screws are single-use components. They must screwed in manually using a 1.2 mm hex screwdriver (hex screwdriver ref. DCM1.2C/DCM1.2/DCM1.2L). The...

Open the catalog to page 8
Global D Therapeutic arsenal - Surgery - 9

3.0 implant Healing screw twinkon® 4 healing screw Signature of the emergence profile Preparation of the prosthetic seating The healing screw (diameter 3.5 mm) is an essential component in the restoration phase of the 3.0 implant system as it prepares the prosthetic seating for the final component (diameter 3.4 mm). It enables tension-free insertion of the prosthetic component. Healing screw/tapered pillar abutment The preparation of the prosthetic seating can be managed either using a healing screw placed directly on the implant, or using a tapered pillar abutment fitted with its cover cap....

Open the catalog to page 9
Global D Therapeutic arsenal - Surgery - 10

Technical information TA6V ELI (Extra Low Impurity) medical grade titanium alloy, the material of choice for dental implantology TA6V ELI, a biocompatible alloy SA2 osteoconductive surface treatment TA6V ELI is an alloy formed by multiple melting operations, in order to obtain a very low level of impurities. SA2 treatment on the endosseous part of the implants gives the TA6V ELI a surface condition with a double level of osteoconductive roughness. The topography obtained promotes contact osteogenesis after 3 weeks in beagles. After 12 weeks, the turns of the implant are filled with newly...

Open the catalog to page 10
Global D Therapeutic arsenal - Surgery - 11

Technical information The prosthetic connection at the heart of the implantable device Global D partner for your success In-Kone®, high-performance connection High mechanical and antibacterial performance The quality of the implant-prosthesis joint is a key factor for the long-term clinical success of restorations supported on implants. In industrial terms, the mechanical and antibacterial performance of the interface is closely linked to the precise fit between the male and female parts and also the control of their surface conditions. Committed designers An experienced technical team...

Open the catalog to page 11

All Global D catalogs and technical brochures

  1. GRAFTEK