SWISS optio HP stabilo mini Safety through Precision The HP stabilo mini at a glance : - suitable for all applications which require very stable outlet pressure under high flow rates and simultaneously small design size - despite its single-stage construction the integrated compensation provides constant outlet pressure also with falling cylinder pressure - for preset working pressure or for continuous adjustment up to 10 bar - very compact single-stage construction with lateral inlet connection - mainly intended for the supply of medical devices in clinics The area of application of the medical pressure reducing valve HP stabilo mini is anywhere, where a preset working pressure is required with both high pressure stability and small construction. Due to the in-built pressure compensation the HP stabilo mini provides very stable working pressure while the gas cylinder is being emptied despite the single-stage construction. The HP stabilo mini has a gauge for indication of the cylinder pressure (and for the version with adjustable pressure also a working pressure gauge), and as well a pressure relief valve. The outlet (version with adjustable working pressure), resp. the two outlets (version with preset pressure) can be equipped with self-closing outlets, NIST housings or quick couplings so that for example tubes can be connected to supply medical devices. The HP stabilo mini is either preset by the manufacturer to a fixed working pressure of 0.5 to 10 bar or it is available with adjustable working pressure for various pressure ranges (0-1.5, 0-4 or 0-10 bar). The HP stabilo mini corresponds to the norm EN ISO 10524-1. CE marking according to the Guideline for Medical Products 93/42/EEC, Annex IX, class IIb.

Open the catalog to page 1
SWISS optio HP stabilo mini - 2

Technical data : Construction Inlet pressure Outlet pressure Flow rate Gas Inlet Outlet Material Sealing material Operating temperature Dimensions Weight single-stage inlet pressure compensated diaphragm pressure reducing valve max. 200 bar preset or adjustable between 0.5 to 10 bar 600 l/min / 36 Nm3/h (inlet pressure 21 bar, outlet pressure 10 bar) O2, AIR, N2O, CO2, He, Xe, N2, test gas mixtures lateral cylinder connection DIN, NF, AGA, BS, UNI, PIN-Index (others on request) Version with preset pressure : 2 x G1/4“ inner thread (one outlet downward, one outlet lateral 65°) Version with...

Open the catalog to page 2

All GLOOR MEDICAL catalogs and technical brochures