Catalog excerpts
Safety through Precision SWISS optio reduc hp2 The reduc hp2 at a glance : - For the variable regulation of a working pressure of 0-10 bar - Extremely constant working pressure thanks to the two-stage construction - High flow capacity - For the direct connection of one medical gas consumer - With integrated pressure relief valve - Mainly intended for use in clinics The reduc hp2 medical pressure reducing valve is used for the direct supply of a consumer with medical gas at a variable or fixed supply pressure from a high pressure gas cylinder. Thanks to the two-stage construction, the pressure reducing valve provides a very constant working pressure while the gas cylinder is being emptied. The first pressure stage reduces the cylinder pressure to 20 bar. The pressure can then be adjusted between 0-10 bar in the second pressure stage. The reduc hp2 is fitted with a high pressure gauge for the cylinder pressure and a low pressure gauge for the indication of the set working pressure (both gauges according EN 837-1). Depending on the model, the desired working pressure can be adjusted using the regulating handle, or can be set to the desired working pressure in the factory. The reduc hp2 is used for the direct supply of medical equipment, flow measuring devices or for the direct feed of an emergency supply of a central medical gas supply system. The reduc hp2 is certified in accordance with EN ISO 10524-1 (incl. ignition test for oxygen); CE marking according to the Guideline for Medical Products 93/42/EEC.
Open the catalog to page 1Technical data : Construction Inlet pressure Outlet pressure Flow rate Irregularity coefficient i Gas Inlet Outlet Material Sealing material Operating temperature Dimensions Weight Two-stage diaphragm pressure reducing valve 200 bar 0-1.5 / 0-4 / 0-6 / 0-10 bar or preset at customers request Q1 = 18 Nm3/h / Qmax = 28 Nm3/h ~0 (P1=200...20 bar) Air, O2, CO2, N2O, N2, He, Xe, test gas mixtures Cylinder connection DIN, NF, AGA, BS, PIN-Index, UNI (others on request) Lateral with G1/4" inner thread, NIST, quick coupling Brass body, external parts nickel-plated EPDM, Si, PA, PEEK -20° to +60° W...
Open the catalog to page 2All GLOOR MEDICAL catalogs and technical brochures
-
SWISS optio jetflow
2 Pages
-
SWISS optio NO
2 Pages
-
SWISS optio mini
2 Pages
-
SWISS optio basic regflow
2 Pages
-
SWISS optio cylinder trolley
1 Pages
-
SWISS optio reduc hp1
2 Pages
-
SWISS optio HP stabilo
2 Pages
-
SWISS optio varius
2 Pages
-
SWISS optio HP stabilo mini
2 Pages
-
SWISS optio basic
2 Pages
-
SWISS optio regflow
2 Pages
-
SWISS optio humidifier
1 Pages
-
SWISS optio hoses
2 Pages
-
Medical cylinder trolley
2 Pages
-
SWISS optio Y-manifold
2 Pages
-
SWISS optio combined holder
2 Pages
-
SWISS optio gas mixer
2 Pages
-
SWISS optio flow switch
2 Pages
-
SWISS optio accessories
6 Pages
-
SWISS optio adapters
2 Pages
-
SWISS optio varius clean
2 Pages
-
SWISS optio clean vent
2 Pages
-
SWISS optio clean vent mini
2 Pages
-
SWISS optio low vac
2 Pages
-
SWISS optio clean vac
2 Pages
-
SWISS optio reduc LP
2 Pages
-
SWISS optio change-over
3 Pages