1. Catalogs
  2. GM Instruments
  3. ASRA Curve Audiometer

ASRA Curve Audiometer

ASRA Curve Audiometer

ASRA Curve Audiometer

Product catalog summary
Introduction
The ASRA Curve Audiometer is a state-of-the-art device designed for precision in audiometric measurements. It features advanced electronics and software for enhanced flexibility, reliability, and user-friendliness. Unique features include quick headset swapping and easy portability between PCs.
Specifications
  • Noise reduction headset included.
  • Comes with all necessary cables, testing, and batch utility analysis software.
  • Includes a manufacturer's calibration certificate.
  • Performs air conduction screening with additional software for annual statistics and recall lists.
  • Wide intensity range from -10dB to +110dB and frequency range from 125Hz to 8kHz.
  • Storage of audiograms on disk and A4 format printout of results.
  • Single or multiple pulse options and export of results data for modern database software.
Software Features
  • Automatic test routines following British Society of Audiology recommendations.
  • Automatic or manual testing routines with recall date calculation and operator override.
  • Adaptation of test protocol to suit patient or operator needs.
  • Recall of stored results for comparison with current tests.
Batch Utility Software
  • Production of recall and test lists with detailed information.
  • Statistical analysis of audiograms with print options for annual statistics.
  • Word Mail Merge for generating referral documentation.
  • Trend analysis for identifying accelerated hearing loss.
Technical Details
  • Compatible with laptops or desktops with a free USB port and recent Windows version.
  • Test time from 5 minutes with frequencies ranging from 125Hz to 8kHz.
  • Frequency accuracy of ± 0.1% and harmonic distortion of 1%.
  • Complies with standards: Audiometry BS EN 60645, Electrical Safety BS EN 60601, CE Marked Class IIa.
  • Size: 22 x 23 x 3.5 cm, Weight: 0.5 Kg, Power: 100/240V 12.6W.
Contact Information
GM Instruments Ltd., Greig House, Annickbank Campus, Annick Road, Irvine, KA11 4LF, United Kingdom. Phone: +44 [0] 1294 554 664, Email: [email protected], Website: www.gm-instruments.com
See more

Catalog excerpts

ASRA Curve Audiometer-1

ASRA CURVE AUDIOMETER INTRODUCING THE NEW ASRA CURVE AUDIOMETER Our latest audiometer development incorporates state of the art electronics and software for flexibility, reliability, and ease of use. The ASRA Curve performs air conduction screening, backed up with additional software to perform tasks such as annual statistics and recall lists. Designed to build on the reputation of the ASRA Classic, the new Curve offers many of the same unique features but combines the latest electronics with a smaller product to better fit current healthcare environments. Unique to the ASRA Curve is the ability to quickly swap headsets (and calibration) and to easily move the unit between PC’s. It comes complete with a noise reduction headset, all cables, testing and batch utility analysis software, and a manufacturer’s calibration certifica

 Open the catalog to page 1
ASRA Curve Audiometer-2

ASRA CURVE AUDIOMETER The ASRA main program provides: The ASRA batch utility software also provides: Automatic test routines following the British Society of Audiology recommendations for pure tone testing. Production of recall lists showing name, ID number, audiogram date, recall date, and previous result categorisation. Automatic or manual testing routines. Recall date calculation with operator override. Production of test lists containing the same information but based on a previous time range and selected by audlogram date. Wide Intensity range (-10dB to +110dB) to allow accurate assessment...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.