GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis
5Pages

{{requestButtons}}

Catalog excerpts

GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis - 1

GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis BALLOON EXPANDABLE ENDOPROSTHESIS

Open the catalog to page 1
GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis - 2

RESTORATION OF LUMEN DIAMETER TARGET SITE 100% MAINTENANCE OF STENT LENGTH Median Length Change = 0 mm in the U.S. IDE Study ≤ 30% residual stenosis due to high radial strength, even in highly calcified and non-compliant lesions* Flexible Strength. Proven Success.

Open the catalog to page 2
GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis - 3

STENT DELIVERY PRIMARY PATENCY * • 100% delivery to target lesion • 100% stent retention • 100% deployment at the target site • 234 devices delivered – 50% bilateral treatment – 42% kissing stents – 32% TASC II C & D including occlusions – 18% contralateral deliveries – predilatation not required Flexible Strength. Proven Success. 95.3% Primary Patency in TASC I

Open the catalog to page 3
GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis - 4

Procedural economic value GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis (VBX Stent Graft) delivers an estimated savings of $1,124 / case** • 79 mm length reduces the number of devices needed in certain instances Advanced technology and unique design Stainless steel independent rings enhance flexibility • Minimizes foreshortening • Provides high radial strength • Not required to pre-dilate with the VBX Stent Graft • Reliable delivery with no device dislodgements • Accurate delivery helps avoid stent foreshortening and elongation Semi-compliant covered balloon • Enables diameter...

Open the catalog to page 4
GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis - 5

GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis Flexible Strength. Proven Success. See flexible strength in action: goremedical.com/vbx-expands W. L. Gore & Associates, Inc. Flagstaff, AZ 86004 +65.67332882 (Asia Pacific) 00800.6334.4673 (Europe) 800.437.8181 (United States) 928.779.2771 (United States) * Data on file. Based on nine month results from the Gore VBX FLEX IDE Clinical Study (N=134 subjects) and follow-ups conducted for US FDA approval. ** Data on file. INTENDED USE / INDICATIONS: The GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis is indicated for the treatment of de...

Open the catalog to page 5