1. Catalogs
  2. Grant Instruments
  3. Analogue Ultrasonic EN Bath XUBA Series

Analogue Ultrasonic EN Bath XUBA Series

Analogue Ultrasonic EN Bath XUBA Series
1 / 94 PagesView full catalog

Analogue Ultrasonic EN Bath XUBA Series

Product catalog summary
Introduction
This document serves as a user manual for Grant ultrasonic baths, specifically models XUBA1 and XUBA3, detailing specifications, procedures, and safety guidelines for professional indoor use.
Safety Instructions
The XUBA Series ultrasonic baths require a 230VAC fully earthed supply. Never operate without an earth connection or use incorrect fuse ratings. The bath must be at least ¾ full of liquid before use, and a basket should support items being cleaned. Avoid using toxic, flammable, acidic, caustic, or corrosive solutions.
Installation
The package includes a basket, lid, and Grant M2 detergent sample. Place the bath near a drain for easy drainage. Connect to a suitable socket, ensuring plug and switch accessibility. Fill with water and detergent before use.
Quick Guide
Fill the bath with cold water to the minimum fill line, add detergent, set the timer, and press the SONICS button to operate. For heating, set the desired temperature and press the HEAT button. Degas the liquid for 5-10 minutes before use. Change the cleaning liquid daily.
Control Panel Instructions
For XUBA1 and XUBA3, set the timer and press the SONICS button to start. XUBA3 includes a heating function controlled by the HEAT button.
Technical Information
Degassing is essential for optimal ultrasonic activity, typically requiring 10 minutes. Heating aids cleaning, with optimal results at 60°C. Ultrasonic activity can increase liquid temperature by 10-15°C per hour.
Specifications
The baths operate at 44 KHz with a heater range of ambient +5 to 70°C. XUBA1 has a 1.5-liter capacity, while XUBA3 has 2.5 liters.
Ultrasonic Detergents
Detergents enhance cleaning. Grant M2 is suitable for most materials except aluminum and soft metals. Recommended dosage is 2-5% of the tank volume.
Maintenance
Regularly change the cleaning liquid to maintain performance and prevent damage. Only qualified engineers should perform service and repairs.
Disposal
Dispose of the ultrasonic bath according to national regulations. Grant Instruments complies with WEEE regulations.
Returning Equipment
Equipment must be fully decontaminated before returning for service or repair, following MHRA guidelines for medical applications.
Warranty
The warranty covers defects due to faulty material or manufacture for 12 months, extendable to two years for transducer assemblies and five years for the bonding process, provided they are not exposed to liquid or cleaning chemicals. Exclusions include normal wear, misuse, and damage from non-recommended chemicals.
Troubleshooting
If the unit fails to turn on, check the power supply and fuses. Persistent issues should be referred to Grant's service department.
Fuse Ratings
XUBA1 and XUBA3 models require specific fuses: 1.6A for the IEC socket and 5A for the mains plug. Incorrect fuses void the warranty.
Temperature Guidelines
The cleaner can heat up to 70°C, potentially exceeding recommended surface temperatures. Risk assessments and caution labels are advised for high temperatures.
Noise Regulations Compliance
The equipment complies with the Control of Noise at Work Regulations 2005, protecting workers' hearing.
Service Record
Annual servicing by qualified engineers is recommended, with a service record maintained.
See more

Catalog excerpts

Analogue Ultrasonic EN Bath XUBA Series-1

Analogue Ultrasonic Bath XUBA Series Operating Manual

 Open the catalog to page 1
Analogue Ultrasonic EN Bath XUBA Series-3

Grant ultrasonic baths are manufactured in the United Kingdom. Grant ultrasonic baths are manufactured to exacting standards and conform to international standards. XUBA Series Operating Manual

 Open the catalog to page 3
Analogue Ultrasonic EN Bath XUBA Series-4

Safety instructions Use of products The following products are covered by this operating manual:  The products listed above are a series of general purpose ultrasonic cleaning baths designed for indoor use by a professional user. Electrical Connect to a 230VAC fully earthed supply via a 3 pin plug. It can be dangerous to operate an ultrasonic bath without an earth connected. The mains plug is fitted with a 5A fuse. NEVER FIT A FUSE OF A HIGHER RATING. Some baths are fitted with a detachable mains lead. These baths have a mains socket on the rear of the bath fitted with two 20mm fuses. See rating...

 Open the catalog to page 4
Analogue Ultrasonic EN Bath XUBA Series-5

The following parts and accessories are included with the Grant analogue ultrasonic baths: - 1 x basket How to install Locate the bath close to a drain or sink to allow easy drainage of the tank. Connect the mains lead into a suitable mains socket. Ensure that the mains plug and the switch are easily accessible. Fill the bath with water and the correct dose of detergent. The bath is now ready to use. Operating Manual

 Open the catalog to page 5
Analogue Ultrasonic EN Bath XUBA Series-6

Quick guide Pour cold water into the bath so that it reaches the minimum tank fill line (but does not go over the maximum fill line). Add the required dose of detergent (see page 10). Operate the ultrasonics by turning the timer dial to the required time and pressing the SONICS button (where applicable). Operate the heater, if the bath has a heating function, by turning the heater dial to the required temperature and pressing the HEAT button. Fill Line Turn on the ultrasonics for approximately 5-10 minutes to degas the cleaning liquid. (See page 8 for more details on degassing). The bath is now...

 Open the catalog to page 6
Analogue Ultrasonic EN Bath XUBA Series-7

Always keep the bath full of liquid when in operation. Do not put hot water above 50°C into the bath. Always use the basket to support items in the bath. Never expose hands, fingers or other body parts to cleaning solutions. Never use toxic, flammable, acidic, caustic or corrosive solutions. Never breathe the fumes from strong solutions. Rinse the items in clean water once the cycle is complete. Subjecting the bath to improper treatment or misuse will invalidate the warranty. XUBA Series Operating Manual

 Open the catalog to page 7
Analogue Ultrasonic EN Bath XUBA Series-8

XUBA1 Control panel instructions To switch on the ultrasonics: Turn the TIME dial to the desired time, and then press the SONICS button. The SONICS button and the SONICS light will glow. Ultrasonic activity will then commence in the liquid inside the tank and the TIME dial will be heard ticking. At the end of the timed period, the TIME will click off, the SONICS light will go out, and the ultrasonic activity in the liquid will stop. To stop the ultrasonic activity at any time, press the SONICS button while in operation. XUBA Series Operating Manual

 Open the catalog to page 8
Analogue Ultrasonic EN Bath XUBA Series-9

XUBA3 Control panel instructions To switch on the ultrasonics: Turn the TIME dial to the desired time, and the press the SONICS button. The SONICS button and the SONICS light will glow. Ultrasonic activity will then commence in the liquid inside the tank and the Timer dial will be heard ticking. At the end of the timed period, the TIME will click off, the SONICS light will go out, and the ultrasonic activity in the liquid will stop. To stop the ultrasonic activity at any time, press the SONICS button while in operation. To operate the heater: Turn the HEATER dial to the desired temperature, and...

 Open the catalog to page 9
Analogue Ultrasonic EN Bath XUBA Series-10

Technical information The need to degas In order to allow optimum ultrasonic activity, the gases present in ordinary tap water need to be driven out of the cleaning solution. The time needed to degas the liquid varies depending on the amount of gas present in the liquid and the quantity of water in the tank. Grant recommends a degas period of at least 10 minutes. During the degas cycle, you will see bubbles of gas forming on the inside of the bath, and slowly rising to the surface. Degassing is complete when you can no longer see these bubbles. Another indication that the liquid in the bath has...

 Open the catalog to page 10
Analogue Ultrasonic EN Bath XUBA Series-11

XUBA Series Operating Manual

 Open the catalog to page 11
Analogue Ultrasonic EN Bath XUBA Series-12

Ultrasonic detergents Detergents are a vital component in the ultrasonic process, aiding the removal and loosening of debris from the surfaces of items placed in the tank while also intensifying the power of the ultrasonic activity. Grant offers a specially formulated ultrasonic detergent for use in many applications. Grant M2 is a general purpose detergent for all plastics, glass and metals (expect aluminium and other soft metals) which is also suitable for use on medical instruments. Dosing matrix (ml of detergent per tank) Grant recommends a dosage of between 2 and 5% for all detergents. Directions...

 Open the catalog to page 12
Analogue Ultrasonic EN Bath XUBA Series-13

Maintenance It is important to keep your bath clean. Not only will contaminated liquid reduce the performance of the bath, it may also damage it. Change the cleaning liquid regularly. Your cleaning process will determine how often to change the liquid – the more soiled your items, the more often you will need to change the liquid. Change the cleaning liquid at least daily. The base of the bath generates the ultrasonic activity by vibrating at very high speeds. If any contaminants are in contact with the bath, they act as an abrasive, causing wear on the metal surface. In extreme cases, the bath...

 Open the catalog to page 13
Analogue Ultrasonic EN Bath XUBA Series-14

Returning equipment to Grant All equipment being returned to Grant for service, repair or other reason MUST BE FULLY DECONTAMINATED prior to return and include a certificate of decontamination. Failure to do so may result in additional charges or the equipment being returned to the user/sender at Grant’s discretion. Ultrasonic baths which have been used in medical/healthcare applications should be decontaminated/packaged in accordance with MHRA guideline document DB2003(5) ‘Management of Medical Devices prior to Repair, Service or Investigation’. This can be found at www.mhra.gov.uk. This policy...

 Open the catalog to page 14

All Grant Instruments catalogs and technical brochures

  1. Densitometers

    4  Pages

  2. Aspirators

    6  Pages

Archived catalogs

  1. JB Nova

    2  Pages

  2. RTS-1

    2  Pages

  3. LT ecocool

    8  Pages

  4. JB Academy

    2  Pages

  5. SUB Aqua Pro

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.