PCH Series Personal Benchtop Cooler / Heater-1

Dry block for heating and cooling PCH-1, PCH-2 and PCH-3 Compact, flexible, easy to use systems for rapid heating and cooling of microtubes; very effective tools for DNA/RNA sample preparation techniques. Dry blocks for heating and cooling Dry blocks for heating and cooling » PCH-1, PCH-2 and PCH-3 • Cooling/heating setting range from -10°C to 100°C, with very rapid cool down and heat-up times • Stability: ±0.1°C • Choice of three models: capacity for up to 32 microtubes in a combination of two sizes (PCH-1) or up to 20 microtubes of one year warranty • Convenient integral reaction timer with audible alarm Model PCH-1 shown PCH-1 Block holds a combination of two microtube sizes simultaneously – up to a total of 32 tubes: 12 x 1.5ml plus 20 x 0.5ml. PCH-2 up to a total of 20 x 1.5ml mictrotubes. PCH-3 up to a total of 20 x 2ml microtubes. Ingenious block construction, combined with powerful Peltier cooler, produces very rapid heating and cooling. Dry temperature control system maintains clean and aerosol-free environment. 2-line LCD display clearly indicates both set and actual values for temperature and time. Rapid DNA denaturation at 95°C quickly achieved. DNA denaturation techniques further supported with an audible alarm for denaturation ‘time-up’; samples can then be quickly cooled. Simple push button combinations for easy set-up. • Life-science - storing restriction enzymes, nick translations, ligation reactions, restriction digests, protein solubilisation for PAGE, warm incubation of microcentrifuge tubes for hybridisation, enzyme reactions and deactivations • Clinical - cooling blood samples prior to coagulation testing © Grant Instruments (Cambridge) Ltd

 Open the catalog to page 1
PCH Series Personal Benchtop Cooler / Heater-2

Dry blocks for heating and cooling Dry blocks for heating and cooling » PCH-1, PCH-2 and PCH-3 » Technical specifications Dry blocks for heating and cooling – Technical specifications PCH-1 PCH-2 h: 165mm d: 260mm w: 240mm weight: 3.2kg Block dimensions Temperature control range Setting resolution Temperature display Heat up time 2 line x 16 character LCD 25°C to 37°C °C/min Cool down time Input voltage Power consumption © Grant Instruments (Cambridge) Ltd 20 x 1.5 1 min to 96 hrs/non-stop Input AC 120-230V, 50/60Hz Output DC 12V External power supply Temperature setting range

 Open the catalog to page 2

All Grant Instruments catalogs and technical brochures

  1. Densitometers

    4  Pages

  2. Aspirators

    6  Pages

Archived catalogs

  1. JB Nova

    2  Pages

  2. RTS-1

    2  Pages

  3. LT ecocool

    8  Pages

  4. JB Academy

    2  Pages

  5. SUB Aqua Pro

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.