
Catalog excerpts

Dry block for heating and cooling PCH-1, PCH-2 and PCH-3 Compact, flexible, easy to use systems for rapid heating and cooling of microtubes; very effective tools for DNA/RNA sample preparation techniques. Dry blocks for heating and cooling Dry blocks for heating and cooling » PCH-1, PCH-2 and PCH-3 • Cooling/heating setting range from -10°C to 100°C, with very rapid cool down and heat-up times • Stability: ±0.1°C • Choice of three models: capacity for up to 32 microtubes in a combination of two sizes (PCH-1) or up to 20 microtubes of one year warranty • Convenient integral reaction timer with audible alarm Model PCH-1 shown PCH-1 Block holds a combination of two microtube sizes simultaneously – up to a total of 32 tubes: 12 x 1.5ml plus 20 x 0.5ml. PCH-2 up to a total of 20 x 1.5ml mictrotubes. PCH-3 up to a total of 20 x 2ml microtubes. Ingenious block construction, combined with powerful Peltier cooler, produces very rapid heating and cooling. Dry temperature control system maintains clean and aerosol-free environment. 2-line LCD display clearly indicates both set and actual values for temperature and time. Rapid DNA denaturation at 95°C quickly achieved. DNA denaturation techniques further supported with an audible alarm for denaturation ‘time-up’; samples can then be quickly cooled. Simple push button combinations for easy set-up. • Life-science - storing restriction enzymes, nick translations, ligation reactions, restriction digests, protein solubilisation for PAGE, warm incubation of microcentrifuge tubes for hybridisation, enzyme reactions and deactivations • Clinical - cooling blood samples prior to coagulation testing © Grant Instruments (Cambridge) Ltd
Open the catalog to page 1
Dry blocks for heating and cooling Dry blocks for heating and cooling » PCH-1, PCH-2 and PCH-3 » Technical specifications Dry blocks for heating and cooling – Technical specifications PCH-1 PCH-2 h: 165mm d: 260mm w: 240mm weight: 3.2kg Block dimensions Temperature control range Setting resolution Temperature display Heat up time 2 line x 16 character LCD 25°C to 37°C °C/min Cool down time Input voltage Power consumption © Grant Instruments (Cambridge) Ltd 20 x 1.5 1 min to 96 hrs/non-stop Input AC 120-230V, 50/60Hz Output DC 12V External power supply Temperature setting range
Open the catalog to page 2All Grant Instruments catalogs and technical brochures
-
Densitometers
4 Pages
-
Aspirators
6 Pages
-
Dry Block Heaters
18 Pages
Archived catalogs
-
LT ecocool
8 Pages
-
Scientific Catalogue 2016
154 Pages
-
RTS-1
2 Pages
-
JB Nova
2 Pages
-
Refrigerated immersion Coolers
12 Pages
-
PV-1 Vortex Mixer
3 Pages
-
MMS-3000 Magnetic Stirrer
2 Pages
-
PMS-1000i Microplate Shaker
2 Pages
-
Orbital Shaking Platform
3 Pages
-
ES-20 Shaker-incubator
3 Pages
-
UV cabinet UVT-B-AR
5 Pages
-
UVC/T-M-AR PCR UV Cabinet
5 Pages
-
DEN-1 & DEN-1B Densitometer
3 Pages
-
Data Acquisition Catalogue
43 Pages
-
BTD Dry Block Heating System
2 Pages
-
Scientific Catalogue
151 Pages
-
heated circulating baths
14 Pages
-
JB Academy
2 Pages
-
SUB Aqua Pro
2 Pages