Catalog excerpts

2 Refrigerated/ heating circulating bathsand recirculating chillers Optima™ range Refrigerated circulating baths RC series Recirculating chillers
Open the catalog to page 1
Refrigerated / heating circulating baths / recirculating chillers Refrigerated/heating circulating baths » Optima™ range Optimarefrigerated/heating bathsandcirculators Cost-effectiveandefficientmulti-purposesystemsforlowtemperatureapplications. Powerful precision cooling whetherusedinopen-looporclosed-loopformat Combining legendary quality, reliability and design for everyday usage –usefulfeatures,straightforwardmaintenance,compactdesign Ⅲ Robust, durable construction forlongevity,reliabilityandlong-termlowcostofownership Ⅲ A comprehensive range...
Open the catalog to page 2
showcase –mid range example ModelTC120-R2range-20to100°C,stability±0.1°C Ourmostpopularmodel–aversatilesystemforthelaboratory,withacomprehensive specificationtosuitmostlowtemperatureapplications. Ⅲ Optima™ digital thermostat (TC120) for precise temperature control Ⅲ Cooling/heating range -20°C to 100°C Ⅲ Stability ±0.1°C Ⅲ Easy to use rotary dial and two function keys Also available as a kit (LTC2) see page 2.6 Clear 4 digit display – easy to read from a distance for instant reassurance Adjustable over temperature protection provides sample protection Visual alarm and countdown timer –...
Open the catalog to page 3
Factorstoconsiderwhenchoosingyoursystem Ⅲ Do you need to immerse samples within a tank? Consider the working area required. The table on p. 2.4 shows the dimensions of the top opening and the min/max liquid depths Ⅲ Cooling power required at a given temperature For example, if your operating temperature is 0°C, and you need 500 W cooling power, you will need the R4 (or R5) refrigeration unit with any of the controllers. Alternatively to calculate the power required use the following formula: W= Ⅲ Cool-down time required to reach that temperature W = average cooling power V = total system...
Open the catalog to page 4
Refrigerated/heatingcirculatingbaths–models,optionsandaccessories Effective operating temperature range (refrigeration unit + thermostat) Ⅲ 0°C to 100°C Ⅲ -20°C to 100°C Ⅲ -30°C to 100°C Ⅲ -47°C to 100°C Key to symbols « display π timer Ë pump : USB/RS232 S drain 0 program storage fixed over temperature cutout relay/ relay control N visual alarm audible alarm 5 5 point re-calibration menu system · external probe socket programmable 2 2 point recalibration refrigeration high pressure switch adjustable over temperature cutout Thermostaticcontrolunits General purpose digital Advanced digital...
Open the catalog to page 5
Refrigerated / heating circulating baths / recirculating chillers Refrigerated / heating circulating baths » Technical specifications General purpose digital Advanced digital Uniformity (DIN 12876) Setting resolution full colour QVGA TFT Timer function No. stored temperature values Re-calibration points Socket for external probe (TXPEP, TXSEP) Communications interface over temperature adjustable cut-out Language capability fluid level – float switch Alarms (can be configured to switch a relay) Electrical power Heater power Height above tank rim Depth below tank rim...
Open the catalog to page 6
Replacement plastic pump inlet/outlet connector. Fits tubing 9mm inner dia. Temp range -50˚C to 200˚C Replacement plastic pump inlet/outlet connector. Fits tubing 15mm inner dia. Temp range -50˚C to 200˚C Stainless steel pump inlet/outlet connector, M16 x 1 male. Fits M16 hose. Temp range -50˚C to 200˚C Metal pump inlet/outlet connector, dual seal super rapid 4mm. Fits semi rigid tubing 4mm outer dia. Temp range -20˚C to 100˚C Metal pump inlet/outlet connector, dual seal super rapid 6mm. Fits semi rigid tubing 6mm outer dia. Temp range -20˚C to 100˚C Metal pump inlet/outlet connector, dual...
Open the catalog to page 7
Refrigerated / heating circulating baths / recirculating chillers Refrigerated / heating circulating baths » Recirculating chillers » RC series Recirculatingchillers RCseries Comprehensiverangeofrobustre-circulatingchillersdeliveringaconstantflowof temperature-controlledliquidtoprovidepowerful,regulatedcoolingat-10ºCformanytypes ofindustrialmachineryandscientificapparatus.Suitableforcirculationthroughopenand closedsystems. Ⅲ Temperature range -10ºC to 60ºC or -5ºC to 60ºC (model dependent) Ⅲ Stability ±0.25ºC or ±0.5ºC (model dependent) Ⅲ Choice of models with different cooling power – from...
Open the catalog to page 8
Re-circulating chillers – digital control Temperature range Display resolution Typical cooling power, ambient 20°C Heater power Overall consumption Pump head pressure @ 1 L/min Pipe connection, inlet/outlet Liquid flow rate, maximum Reservoir capacity – temperature fixed over temperature cut-out Electrical supply flow-fail device Safety: – temperature switchable undertemperature thermostat – level Refrigerated / heating circulating baths / recirculating chillers Refrigerated / heating circulating baths » Recirculating chillers » Models and specifications * with 10 litres of water in the...
Open the catalog to page 9All Grant Instruments catalogs and technical brochures
-
Densitometers
4 Pages
-
Aspirators
6 Pages
-
Dry Block Heaters
18 Pages
Archived catalogs
-
LT ecocool
8 Pages
-
Scientific Catalogue 2016
154 Pages
-
RTS-1
2 Pages
-
JB Nova
2 Pages
-
Refrigerated immersion Coolers
12 Pages
-
PV-1 Vortex Mixer
3 Pages
-
MMS-3000 Magnetic Stirrer
2 Pages
-
PMS-1000i Microplate Shaker
2 Pages
-
Orbital Shaking Platform
3 Pages
-
ES-20 Shaker-incubator
3 Pages
-
UV cabinet UVT-B-AR
5 Pages
-
UVC/T-M-AR PCR UV Cabinet
5 Pages
-
DEN-1 & DEN-1B Densitometer
3 Pages
-
Data Acquisition Catalogue
43 Pages
-
BTD Dry Block Heating System
2 Pages
-
Scientific Catalogue
151 Pages
-
heated circulating baths
14 Pages
-
JB Academy
2 Pages
-
SUB Aqua Pro
2 Pages