2010 GSI AUDIOscreener-1

Product Specifications General Specifications • Stimulus types: Click 100 µsec width, Blackman window tone pips (2KHz, 4KHz) • Low Battery, Dead Battery • Test Types: Distortion Product Otoacoustic Emissions, Transient Evoked Otoacoustic Emissions and Auditory Brainstem Response • Stimulus Polarity: Rarefaction, Condensation, Alternating • Internal Circuit Error • Stimulus Rate: 32 to 62 per second Quality System • Screening Methods: Presence/Absence (DPOAE & ABR), Level (DPOAE & TEOAE), or Latency (ABR) • Stimulus Intensity: 0 to 100dB in 5dB steps • Manufactured, designed, developed and marketed under an ISO 13485, ISO 9001 certified quality system • Display: Pass/Refer/Noise or Graphical • Reports: Simple or Detailed • ABR tests: Using Comfort Cups or Probe – protocols included • Level Measurement Accuracy: ± 1 dBSPL • Input Frequency Range: 30Hz to 3,000Hz • Waveform latency Delay: ±0.2 msec • Common Mode Rejection: 108 dB • Gain: 43 dB • Database Error Compliance/Regulartory Standards Designed, tested and manufactured to meet the following domestic (USA), Canadian, European and International Standards: • Automated Impedance Testing • Data Transfer: Infrared to computer or printer • Automated Pass criteria: ABR Fsp • UL 2601-1 Standard for Safety Medical Equipment • IEC 601-1-2 Medical Electrical Equipment CISPR 11 (EN55011) • Power AC Adaptor: 100-240VAC • Line Frequency Range: 50 to 60 Hz • NiMH 2150 mAh • Operating life: Approximately 24hrs • Recharge time: Approximately 2hrs System Configuration DPOAE Operating Specifications • Frequency Range: 2,000 Hz to 6,000 Hz, ±2% • Frequency Resolution: 50Hz • Level Measurement Accuracy: ± 1 dBSPL • Each AUDIOscreener+™ comes with AUDIOtrac™, a Windows based patient database software package System Requirements for AUDIOtrac • Windows Operating system (95, 98, 2000, ME, XP, or NT) • Test Time: Varies dependent on parameters selected • CD-ROM Drive • Automated pass criteria: DPOAE SNR and/or DPOAE Level • 3.5”, 1.44 Mb floppy disk drive • 5 Mb or more available space on hard drive • An Infrared port (IrDA) set to COM 1. TEOAE Operating Specifications • Frequency Range: 250 Hz to 5,250 Hz, ±2% • For systems that do not have an IrDA as standard a special IrDA is provided • Screen resolution 800 x 600 or larger • Level Measurement Accuracy: ± 1 dBSPL • Dynamic Range: 96 dB • Test Time: Varies dependent on parameters selected • Automated pass criteria: TEOAE SNR and TEOAE Reproducibility Setting The Clinical Standard Environmental • Temperature: - Storage: 32° F to 122° F - Operating: 50° F to 104° F - Humidity: up to 95%, (non-condensing) Grason-Stadler, 7625 Golden Triangle Drive, Suite F, Eden Prairie MN 55344 800-700-2282 • 952-278-4402 • fax 952-278-4401 • e-mail

 Open the catalog to page 1

All Grason-Stadler catalogs and technical brochures

  1. TYMPSTAR PRO

    8  Pages

  2. GSI 39

    6  Pages

  3. NOVUS

    6  Pages

  4. Pello

    2  Pages

  5. ALLEGRO

    6  Pages

  6. GSI CORTI™

    8  Pages

  7. AUDERA

    8  Pages

  8. GSI_Corti

    2  Pages

  9. GSI Tympstar

    6  Pages

  10. GSI 70

    6  Pages

  11. GSI 61

    6  Pages

  12. GSI Audera

    6  Pages

Archived catalogs

  1. GSI 18™

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.