Antisera for conventional techniques brochure
12Pages

{{requestButtons}}

Catalog excerpts

Antisera for conventional techniques brochure - 1

Antisera THE ideal COMPANION Low resolution PDF file. For high resolution files, please contact Corporate Communications corporatecomms@grifols.co

Open the catalog to page 1
Antisera for conventional techniques brochure - 2

WHEN YOU NEED to resolve COMPLEX CASES The ideal companion In your daily work routine, you rely on the quality and efficiency of column agglutination technology, such as Grifols DG Gel®. However, whether you operate a small laboratory or a larger fully automated service, there are times when you will need to adopt conventional techniques for resolving any problematic cases that may arise. It is vital for you to have a wide range of conventional reagents: the tube technique continues to be the method of reference for analyzing complex samples, and is used by all Transfusion Services and the...

Open the catalog to page 2
Antisera for conventional techniques brochure - 3

Benefit from our experience Grifols has a vast amount of experience and expert knowledge in the field of Transfusion Medicine, and we offer a full range of blood typing solutions to meet all your different needs. In our catalogue of conventional reagents you will find a wide range of ABO and Rh monoclonal antisera, rare antisera for the extended phenotype, anti-human globulin, internal quality controls, enhancing media, solutions and instrumentation. In addition we supply one Rh negative control and a unique Neutr-AB® II reagent for use to diagnose Hemolytic Disease of the Newborn (HDN). By...

Open the catalog to page 3
Antisera for conventional techniques brochure - 4

• We have many different formats. Choose the best one for you and optimize your costs! ABO & RHESUS monoclonal antisera • An anti-D that detects the DVI variant (IgM/IgG blend), and two that do not detect it (clones MS-201 and RUM-1). • Antisera that are fast to process, incubation in less than 5 minutes. Perfect for when you need results quickly! ANTIBODY TYPE & ORIGIN Anti-A Mono-Type® Anti-B Mono-Type® Anti-A,B Mono-Type® lectin from Dolichos biflorus Anti-H Mono-Type®* Combi Anti-D Mono-Type® monoclonal human IgM/IgG blend Anti-CW Mono-Type® * This same product is also validated for use...

Open the catalog to page 4
Antisera for conventional techniques brochure - 5

• A wide range of high quality monoclonal and polyclonal antisera for typing rare antigens. • Our product range is under constant development, so that we respond to all of your needs. Rare antisera DESCRIPTION ANTIBODY TYPE & ORIGIN Anti-K polyclonal polyclonal human Anti-k (Cellano) Mono-Type®* Anti-k (Cellano) polyclonal human polyclonal human polyclonal human polyclonal human Anti-Fya Mono-Type®* polyclonal human polyclonal human Anti-Jk Mono-Type Anti-Jk Mono-Type Anti-Lea Mono-Type® Anti-Le Mono-Type polyclonal human polyclonal human Anti-M Mono-Type polyclonal human polyclonal human...

Open the catalog to page 5
Antisera for conventional techniques brochure - 6

Anti-Human Globulin sera • Anti-Human Globulin is used for in vitro detection of sensitized erythrocytes that do not agglutinate in a saline medium. • A wide range of polyspecific and monospecific anti-globulins for detecting sensitization by different types of antibodies and antibodies against different components of the complement. • Many different formats of the most common polyspecific AHG Sera are available; by selecting the best format for your laboratory, you can optimize costs.

Open the catalog to page 6
Antisera for conventional techniques brochure - 7

• The ideal product for determining HDN due to ABO incompatibility. Low resolution PDF file. For high resolution files, please contact Corporate Communications corporatecomms@grifols.com Neutralization solution: Neutr-AB® II This product is a neutralizing solution of human isohemagglutinins of IgM class. It is extremely useful for studies of Hemolytic Disease of the Newborn (HDN) due to ABO incompatibility between group O mother and fetus, since the titer of anti-A and anti-B IgG antibodies that are not neutralized by the product can be determined. If the titer overtakes the empirical...

Open the catalog to page 7
Antisera for conventional techniques brochure - 8

Quality controls Essential II Control This quality control is for use with ABO/Rh(D) grouping, determination of the Rh phenotype and K antigen and screening of irregular antibodies. It can be used in conjunction with conventional techniques, the DG Gel® System (manual or automated) and the MDmulticard® System (ref. 210503 & 210505). • It consists of a double set of two simulated whole blood tubes (Hct 15% ±2%). • The tubes configuration is as follows: Tube 1 A rr (ccddee), Kpos, with anti-B and anti-D (approx. 0.05 IU/ml) Tube 2 R1R2 (CcD.Ee) K neg., Fya neg.with B anti-A and anti-Fya...

Open the catalog to page 8
Antisera for conventional techniques brochure - 9

Dweak Control A positive control for polyspecific or monospecific antiglobulin tests. It provides a sure way to rule out the possibility of false negative results, occasionally caused by insufficient cells washing, neutralization of the Coombs medium, inadequate washing of the tubes, non functional or undispensed reagents. It is essential when doing AHG tests in conventional methods. A positive control for the detection of D weak antigen to be used in parallel with D typing tests performed with commercial anti-D reagents. • Each vial of Coombs Control contains human red blood cells of O...

Open the catalog to page 9
Antisera for conventional techniques brochure - 10

Enhancing medium and auxiliary solution • An enhancing medium suitable for potentiating the reaction of the most clinically relevant antibodies when working with commercial antisera. • The enhancing medium is available in different formats that adapt to your different requirements.

Open the catalog to page 10
Antisera for conventional techniques brochure - 11

Low resolution PDF file. For high resolution files, please contact Corporate Communications corporatecomms@grifols.com Instrumentation Immufuge IV An easy to use compact centrifuge that holds twelve tubes (12 x 75 mm), and is ideal for use in the blood bank and laboratory. The time, speed and deceleration can be adjusted accordingly. There is a digital LCD control panel and the spin speed can be controlled in rpm or in RCF. The centrifuge operates in silence (< 60 dB) and no maintenance is required. The housing is made from stainless steel and is resistant to corrosion; it can also be used...

Open the catalog to page 11
Antisera for conventional techniques brochure - 12

Do you need to explore even further? Genotyping has been demonstrated to be a highly effective tool that complements serology in extremely challenging cases. Send us your complex samples, and we will use the latest blood group genotyping technologies to resolve any doubts. For conclusive results, ask your sales representative about Grifols BLOODchip Service . I.H. Laboratory DNacHiptecHnolo gy XMPap advanced MOLECULar tecHnologies reference laboratOrY Grifols International, S. A. Av. de la Generalitat, 152 08174 Sant Cugat del Vallès - ESPAÑA These reagents and equipment comply with the...

Open the catalog to page 12

All Grifols catalogs and technical brochures

  1. BlisPack®

    8 Pages

  2. Wadiana®

    6 Pages

  3. PROMONITOR®

    2 Pages