uni-galica
1 / 2Pages

Catalog excerpts

uni-galica - 1

Implants During the 2nd RECO meeting, the remarkable survival of unicondylar prostheses (93.6%) was revealed through the results presented by multiple surgical teams with different implants. The Galica unicompartmental prosthesis, with a 10-year clinical follow-up, has adopted all of these elements to ensure excellent results. Cementless Uni Galica Femur (HA) Right internal / left external Ref. Size Right external / left internal Ref. Unicompartmental knee prosthesis for the mini-invasive approach It includes instrumentation that is simple and validated for the mini-invasive approach. Cemented Uni Galica Femur Right internal / left external Implant name 1/ Galica UNI* Survival rate Clinical follow-up Author 94,80% 9 years Dr PRUDHON Type of implant «Full poly» cemented base «Full poly» cemented base Mobile polyethylene surface on a tibial metal back base «Full poly» cemented base Fixed polyethylene surface on an HA tibial base Dr KELBERINE Mobile polyethylene surface on a tibial metal back base Right external / left internal Ref. Size Pr ARGENSON Fixed polyethylene surface on a cemented tibial base «Full poly» cemented base Fixed polyethylene surface on an HA tibial base *Average of the survival rate / clinical follow-up for the series * special order Cemented Uni Galica Tibial Tray 8 mm Height Ref. Size (in Arthroplastie du genou de 1e intention – expériences cliniques, Sauramps Médical, Montpellier 2008) 1/ J.L. PRUDHON : Prothèse de genou unicompartimentale GALICA, Concepts et résultats à 9 ans de recul 2/ P. CARTIER, J.L. SANOUILLER : L’Arthroplastie unicompartimentale du genou recul minimal de 10 ans 3/ J.J. CALLAGHAN: Mobile-bearing knee replacement:clinical results:a review of the literature 4/ A.CAZENAVE, P. CARTIER : Prothèse unicompartimentale MARMOR Evolution GENESIS 5/ F. LECUIRE, M AUGOYARD, G. BASCOULERGUE, M. BASSO, P. CHARRET : La prothèse uni-compartimentaire Alpina sans ciment, Résultats entre 5 à 8 ans de recul 6/ F. KELBERINE, J. CAZAL : Notre expérience à moyen terme des prothèses unicompartimentales de type Oxford III 7/ J.N. ARGENSON, Y. CHEVROL-BENKEDDACHE, J.M. AUBANIAC : Arthroplastie unicompartimentale du genou cimentée MILLERGALANTE (M-G) 8/ P. NEYRET, T AIT SI SELMI, J.L. PAILLOT : HLS unicompartimentale, Résultats d’une série de 139 cas à plus de 5 ans de recul 9/ J.A. EPINETTE, M.T. MANLEY : Prothèses unicompartimentales de genou à revêtement hydroxyapatite, Notre expérience à 5-13 ans de la prothèse de genou HA UNIX Bone cement without antibiotics Ref. Viscosity Mini invasive program Gentamicin sulfate Ref. Viscosity LÉPINE ALGÉRIE LÉPINE IBÉRICA LÉPINE MAROC 9 rue philosophe Tabrizi Les sources Bir Mourad Rais - ALGER lepine-algerie@groupe-lepine.com C/J.J. Tadeo Murguía N. 3 - 5 BAJO 20304 IRÚN (GUIPÚZCOA) lepine-iberica@groupe-lepine.com 79, avenue Ibn Sina 10.000 RABAT - AGDAL lepine-maroc@groupe-lepine.com 175 rue Jacquard - ZI Lyon Nord 69730 Genay - FRANCE TEL. +33 (0)4 72 33 02 95 FAX +

Open the catalog to page 1
uni-galica - 2

An innovative surgical technique that ensures a silent prosthesis «Full remains a sure value Extra-medullary instrumentation designed for reliable and reproducible surgical technique Two anchoringpegs provide primary mechanical stability of the condyle Femoral geometry optimized for deep flexion DISTAL FEMORAL CUT DONE IN EXTENSION IN THE «MINI INVASIVE PROGRAM» 1. Locate the joint space Extension Trimming the posteriorpeg allows the symmetrical tibial tray to be used medially or laterally 2. Make the distal femoral cut 4. Make the beveled cuts Height of the tray Is optimized Proximal part...

Open the catalog to page 2

All Groupe Lépine catalogs and technical brochures

  1. biomaterials

    4 Pages

  2. PAVI

    2 Pages

  3. MAÏA ™

    2 Pages

  4. INCA ™

    2 Pages

  5. Targos

    2 Pages