SMR 100'S

SMR 100'S
1 / 16 PagesView full catalog

SMR 100'S

Product catalog summary
Contraindications: Hip joint surgery is strictly contraindicated in cases of systemic or local infection, sepsis, and osteomyelitis. It is relatively contraindicated for patients with conditions such as osteoporosis, neurological disorders, systemic or metabolic disorders, osteomalacia, infections, vascular insufficiency, muscular atrophy, obesity, inadequate bone stock, skeletal immaturity, and severe bone deformities.
Product Description: The SMR 100's Modular Hip Stem is designed for hip replacement in cases of dysplasia, fractures, and osteotomies. It includes three components: proximal component, distal component, and locking screw. The proximal component sizes range from 40mm to 70mm, and the distal component is 100mm long.
Indications: The SMR 100's stem is indicated for partial or total hip arthroplasty to treat non-inflammatory degenerative joint diseases, rheumatoid arthritis, osteoarthritis post-fracture, and specific femoral canal morphologies. It is suitable for cementless implants.
Proximal Component: The modular proximal component aids in restoring limb length and stabilizing the joint, available in four lengths (40, 50, 60, 70mm) and two CCD angles (125° and 135°). The mirror-polished neck area reduces polyethylene wear and prevents fatigue cracks.
Distal Component: The conical distal component with longitudinal fins ensures axial stability and resistance to torsional forces, available in nine diameters (14-24mm).
Assembly: Components are assembled using a "Morse taper" allowing 360° rotation. The locking screw secures the taper but does not seal it; the coupling of the tapers ensures the seal.
Materials: Made from Titanium alloy Ti 6Al 4V Grade 5 ELI, ensuring biocompatibility and mechanical strength. The surface is finished with corundum abrasion to enhance prosthesis-bone anchorage.
Pre-operative Assessment: Pre-operative planning involves selecting the diameter and length of the distal component and the size of the proximal component using an anterior-posterior X-ray and templates, which are 15% enlarged.
Reaming of Distal Component: After removing the previous implant, reaming is performed with conical reamers to prepare the femoral canal, corresponding to the sizes of the proximal components.
Insertion of Distal Component: The distal component is inserted using an inserter, ensuring good torsional stability. The final position corresponds to the mark identified during reaming.
Preparation for Proximal Component: The bone is prepared for the proximal component using a tubular reamer, taking care to avoid damaging soft tissues and ensuring no residue hinders the procedure.
Insertion of Trial Proximal Component: The trial proximal component is inserted and locked with an appropriate screw, without excessive tightening.
See more

Catalog excerpts

SMR 100'S-1

SMR 100'S MODULAR HIP STEM VASTAGO MODULAR DE CADERA OPERATING TECHNIQUE TÉCNICA QUIRÚRGICA

 Open the catalog to page 1
SMR 100'S-2

SMR 100'S MODULAR HIP STEM VASTAGO MODULAR DE CADERA The SMR 1OO’S stem is a modular system designed for hip replacement in cases of dysplasia, results of fractures and osteotomies. The stem features three components: proximal component, distal component and locking screw. The proximal component is available in sizes from 4Omm to 7Omm, The distal component is 1OOmm long. El vástago SMR 1OO’S es un sistema modular concebido para el recambio protésico de cadera en los casos de displasia, resultados de fracturas y osteotomías. El implante femoral consta de tres elementos: un componente proximal,...

 Open the catalog to page 2
SMR 100'S-3

PROXIMAL COMPONENT The modular proximal component solves the problem of restoring the physiological length of the limb and stabilizing the joint thanks to its four lengths 40, 50, 60 and 70mm and two CCD angles 125° and 135°. The mirror polished neck area has been studied to decrease polyethylene wear during flexion. In addition, the mirror finish eliminates the risk of fatigue cracks. El componente proximal modular consigue resolver el problema de la restauración fisiológica de la longitud y estabilidad de la articulación gracias a las quatro longitudes 40, 50, 60 y 70mm y los dos ángulos CCD...

 Open the catalog to page 3
SMR 100'S-4

SMR 100'S MODULAR HIP STEM VASTAGO MODULAR DE CADERA Pre-operative assessment Thorough pre-operative planning enables the surgeon to adopt a correct approach to the operation and foresee certain situations that might arise. The objective is to choose the diameter and length of the distal component and size of the proximal component. Pre-operative choice of components is indicative, as the definitive size will be determined intra-operatively. Pre-operative planning requires an anterior-posterior X-ray of the pelvis and pre-operative templates of the SMR 100's stem (provided in the instrument kit)....

 Open the catalog to page 4
SMR 100'S-5

Reaming of distal component Escariado componente distal EN Having completed the removal of the previous implant, proceed to reaming with the conical reamers (Ref. 120540714 ÷ 120540724*). (FIG.2) Reaming may be done manually with the “T” handle (Ref. 110381521) or with a motor, using the Jacobs Adaptor (Ref. 110381525). The instrument kit has reamers with diameters from 14 mm to 20 mm, in 1 mm steps, and 22 mm and 24 mm. Start with a reamer that’s one or two millimetres smaller than the measurement taken in pre-operative planning. The reamers must be inserted into the femoral canal till the depth...

 Open the catalog to page 5
SMR 100'S-6

SMR 100'S MODULAR HIP STEM VASTAGO MODULAR DE CADERA Insertion of distal component Inserción componente distal ES Use of the reamers yields information on the diameter and correct depth of the distal component in the cortical. Mount the distal component inserter (Ref. 120540410) on the chosen component (Ref. 120373914 ÷ 120373924*) and proceed to feed it into the previously prepared canal. Proceed to insertion with the distal component inserter advancing gradually and checking the depth, as far as the maximum, to obtain good torsional stability and avoiding any unexpected penetration under load....

 Open the catalog to page 6
SMR 100'S-7

Preparation of the bone for the proximal component Preparación del hueso para el componente proximal EN Remove the distal component inserter (Ref. 120540410) from the distal component, screw the guide shaft for tubular reamer (Ref. 120540415) onto the distal component. (FIG.4a) When carrying out this operation, make sure it’s done in the right direction, as a mistake could irreparably damage the distal component and compromise all the successive phases. Now ream the proximal portion with the appropriate tubular reamer (Ref. 120540400) to prepare a housing for the proximal component. (FIG.4b)...

 Open the catalog to page 7
SMR 100'S-8

SMR 100'S MODULAR HIP STEM VASTAGO MODULAR DE CADERA Insertion of trial proximal component Inserción componente proximal de prueba ES Insert the trial proximal component and lock it with the appropriate screw (Ref. 120540040 ÷ 120540070). Do not tighten excessively. (FIG.5a) Introducir el componente proximal de prueba, apretándolo con el tornillo adecuado (Ref. 120540040 ÷ 120540070). No apretar excesivamente. (FIG.5a) Trial reduction Mount the trial head (Ref. 110380860 ÷ 110380890, 110380960÷110380990, 110381060÷110381090) on the taper of the trial proximal component (Ref.120540140 ÷ 120540170,...

 Open the catalog to page 8
SMR 100'S-9

Insertion of the definitive proximal component Insertion of the definitive proximal component EN Remove the trial head and trial proximal component using the revision proximal component extractor (Ref. 120540420). Proceed with prudence in the extraction phase and make sure the correct direction is chosen, as a mistake could compromise all the successive phases. Take the definitive proximal component (having the same size as the trial one; Ref. 120362540 ÷ 120362570; 120363540 ÷ 120363570) and use the revision proximal component impactor (Ref. 120540411) to insert it in the Morse taper of the...

 Open the catalog to page 9
SMR 100'S-10

SMR 100'S MODULAR HIP STEM VASTAGO MODULAR DE CADERA Blocking the proximal component Bloqueo del componente proximal ES Insert the locking screw (Ref. 120376140 ÷ 120376170) of the appropriate size for the proximal component used and tighten it with the screwdriver for revision/resection prosthesis (Ref. 120540405). When tightening the screw, use the non-rotation device (Ref. 120540412), which fits into the Morse taper, to prevent rotation during assembly. (FIG.7) The locking screw ensures additional anchoring between the distal and proximal components, as well as holding the Morse taper. Insert...

 Open the catalog to page 10
SMR 100'S-11

Extraction of SMR 100's proximal component Extracción componente proximal SMR 100's EN Should it be necessary to extract the proximal component of the SMR 100's stem, remove the locking screw, screw the extractor for revision proximal component (Ref. 120540420) into the locking screw hole and turn until it’s fully extracted. (FIG.8) En el caso de que sea necesario extraer el componente proximal del vástago SMR 100's extraer el tornillo de bloqueo, atornillar el extractor para componente proximal de révision (Ref. 120540420) en el agujero del tornillo de bloqueo y girar hasta haber completado...

 Open the catalog to page 11

All Gruppo Bioimpianti catalogs and technical brochures

  1. SMR Resection

    4  Pages

  2. DPO Plates

    6  Pages

  3. KORUS SYSTEM

    7  Pages

  4. FIN SYSTEM

    12  Pages

  5. SMR

    10  Pages

  6. 2020 K-MOD

    16  Pages

  7. K-MOD REV

    8  Pages

  8. VET LINE

    18  Pages

  9. K-MONO

    10  Pages

  10. Evo-Nail PLUS

    28  Pages

  11. Spherus

    4  Pages

  12. K-MOD

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.