The Lenstar 900 is an advanced optical biometer by Haag-Streit, designed for precise measurements in cataract surgery. It enhances intraocular lens (IOL) prediction and surgical outcomes through integrated advanced formulas and technologies.
Specifications and Features
The Lenstar 900 offers comprehensive optical measurements from the cornea to the retina, including crystalline lens thickness. It supports advanced IOL prediction with Hill-RBF, Olsen, and Barrett formulas. The device features dual zone keratometry with 32 measurement locations and optional T-Cone topography for accurate astigmatism and axis measurements, crucial for toric lens planning.
Measurement Techniques
Utilizing optical low coherence reflectometry (OLCR), the Lenstar provides accurate axial measurements such as central corneal thickness (CCT), keratometry, white-to-white (WTW) distance, pupillometry, lens thickness, anterior chamber depth (ACD), and axial length (AL). These measurements are vital for diagnosing conditions like glaucoma and planning refractive surgeries.
IOL Calculation and Planning
The Lenstar includes a dual zone keratometer and optional T-Cone topography for enhanced toric IOL planning. The EyeSuite IOL Toric Planner, along with the Barrett Toric Calculator, optimizes surgical procedures by considering both corneal surfaces and lens shape. The Hill-RBF Method, leveraging artificial intelligence, provides superior accuracy for IOL power selection.
Software and Connectivity
The EyeSuite software streamlines patient flow and data management, offering real-time access to biometry results and IOL calculations. It supports electronic medical record connectivity and provides an open data interface for integration with advanced calculation tools.
Product Versions
The Lenstar is available in Essential and Pro versions. The Essential version offers basic functionalities for standard cataract care, while the Pro version includes advanced IOL calculation methodologies and options like the T-Cone Toric Platform and EyeSuite IOL Toric Planner for comprehensive planning and research capabilities.
Lenstar Family and Options
The Lenstar 900 comes in two versions: Essential and Pro. The Pro version includes features such as Dense Cataract Measurement Mode and Automated Positioning System, with the option to upgrade from Essential to Pro on-site.
Measurements and Features
The Lenstar LS 900 measures various ocular parameters including axial length, corneal thickness, anterior chamber depth, lens thickness, keratometry, and pupillometry. It supports multiple IOL calculation methods like Hill-RBF, Barrett Universal II, and Haigis.
Technical Specifications
The device operates as a non-invasive, non-contact OLCR device with specific measurement ranges and resolutions for different ocular parameters, such as corneal thickness (300-800 μm) and axial length (14-32 mm).
Network and Data Interfaces
The Lenstar LS 900 supports electronic medical record interfaces including DICOM and EyeSuite Script Language, allowing integration with various medical systems.
Safety and Compliance
The device is classified as a Class 1 laser product, ensuring safety during use.
Manufacturer Information
The Lenstar LS 900 is produced by HAAG-STREIT AG, a member of the HAAG-STREIT Group, with contact details and website links provided for further information.
See more

Catalog excerpts

LENSTAR 900-1

LENSTAR 900 Improving outcomes Tradition and Innovation – Since 1858, visionary thinking and a fascination with technology have guided us to develop innovative products of outstanding reliability: Anticipating trends to improve the quality of life.

 Open the catalog to page 1
LENSTAR 900-2

LENSTAR Outstanding optic measurement results While the introduction of optical biometry revolutionized cataract surgery in the late 1990s, Haag-Streit is writing the latest chapter in biometry history with its Lenstar 900. The Lenstar provides highly accurate laser optic measurements for every section of the eye − from the cornea to the retina − and is the first optical biometer on the market that can measure the thickness of the crystalline lens. With its integrated Hill-RBF, Olsen and Barrett formulas and the optional IOL Toric Planner considering the posterior cornea, the Lenstar provides...

 Open the catalog to page 2
LENSTAR 900-3

Precise measuring data for the Hill-RBF Method Lenstar’s precise measurement technique in combination with the unique Hill-RBF Method allows accurate prediction of the IOL power for every type of eye. To improve refractive outcomes, Lenstar is the optimal choice. Perfect K values – best toric results The Lenstar features dual zone keratometry or T-Cone topography for precise astigmatism and axis measurement 2,3. The integrated Toric Calculator featuring Barrett12, Hill-RBF and Olsen predicts toric IOL, considering the posterior cornea for best refractive outcomes. For post-refractive cases –...

 Open the catalog to page 3
LENSTAR 900-4

LENSTAR an excellent choice for toric and premium channel IOL The Lenstar is a remarkably easy to use all-in-one IOL power calculation tool that delivers exceptionally accurate axial length, anterior chamber depth and lens thickness by optical biometry. At the same time, its dual zone autokeratometry feature is precise and uniformly consistent. The Lenstar is an excellent choice for surgeons migrating towards torics and other premium channel IOLs where highly accurate outcomes are critical for success. « WARREN E. HILL , MD, FACS MESA, ARIZONA, USA

 Open the catalog to page 4
LENSTAR 900-5

Topography for torics – match the axis With the optional T-Cone toric platform, the axis and astigmatism measurement of Lenstar is extended with true 11-ring Placido topography. This additional data improves the efficacy and safety of toric IOL surgery, eliminating the risk of irregularities and allowing the user to double check the axis location on the topography maps as well as in the surgical planning sketch on high resolution images of the patient’s eye. The T-Cone is combined with the EyeSuite IOL Toric Planner for optimal planning of the intervention based on the Barrett Toric Calculator....

 Open the catalog to page 5
LENSTAR 900-6

Complete optical biometry The all-in-one optical biometer and IOL planning platform Optical coherence biometry has revolutionized cataract surgery. Featuring OLCR technology, Lenstar is redefining optical coherence biometry. Cutting-edge, multivariable IOL calculation formulae, such as the Olsen, Barrett, Holladay 2 formula or Hill-RBF Method for sophisticated IOL calculation, demand more than just the axial length and keratometry measurement. Lenstar provides all the key biometric parameters simultaneously. In a single measurement scan and using optical low coherence reflectometry (OLCR), Lenstar...

 Open the catalog to page 6
LENSTAR 900-7

Central corneal thickness As for every other Lenstar axial measurement, optical coherence biometry is used to measure CCT with stunning reproducibility of ±2 μm. CCT is a key parameter in glaucoma diagnosis, and is also used for laser refractive surgery and/or to differentiate prior myopic or hyperopic LASIK procedures when there is no patient history. Keratometry / Topography Lenstar’s unique dual zone keratometry, featuring 32 marker points, provides perfect spherical equivalent7, magnitude of astigmatism and axis position2,3, making it the biometer of choice for toric IOL's. With the optional...

 Open the catalog to page 7
LENSTAR 900-8

Intuitive and efficient The ultimate platform for toric IOL planning Lenstar features a unique dual zone keratometer with a total of 32 marker points on two concentric rings of 1.65 and 2.3 mm in diameter for improved refractive outcomes with toric lenses2,3. It has now been complemented with an optional TCone topography add-on and the optional toric surgery planning platform EyeSuite IOL Toric Planner. The T-Cone enables the Lenstar to provide true Placido topography of the central 6  mm optical zone. The toric surgery planning platform allows planning and optimization of the surgical procedure...

 Open the catalog to page 8
LENSTAR 900-9

HILL-RBF METHOD A new approach for IOL power selection The Hill-RBF Method is a purely data driven IOL calculation technique incorporating pattern recognition based in artificial intelligence and sophisticated data interpolation. It features a boundary model for improved accuracy and confidence. RBF stands for Radial Basis activation Function a method used in mathematical modeling. The Hill-RBF Method performs as good in short and long eyes15. Used on short eyes, it clearly outperforms Holladay16 and Hoffer Q16 and shows slightly better results than latest theoretical formula16. The elemental...

 Open the catalog to page 9
LENSTAR 900-10

Connectivity is key Open data and intuitive user interfaces for optimal workflow The EyeSuite software is designed for optimal patient flow in busy practices. Paired with Lenstar’s one scan – get all measurements technology and the Automated Positioning System APS biometry acquisition is fast. Sophisticated capture and analysis algorithms − as well as the possibility to review the raw data of every parameter in detail to ensure correct measurement − result in full transparency and confidence that the biometry is accurate and precise. With EyeSuite software, Lenstar is fully networkable and allows...

 Open the catalog to page 10
LENSTAR 900-11

12 | 13 LENSTAR FAMILY AND OPTIONS Your choice Lenstar family and options, get the right tool for your needs The Lenstar is now available in two basic versions: Lenstar Essential and Lenstar Pro. The Lenstar Essential provides all basic functionalities of a stand-alone optical biometer for standard cataract care in a busy practice. As such the Lenstar Essential features the unique Automated Positioning System (APS) as a standard, allowing automatic measurement acquisitions at a single click. A Lenstar Essential may be upgraded on site to Pro at any time, offering the full range of functionality...

 Open the catalog to page 11

All Haag-Streit Diagnostics catalogs and technical brochures

  1. BI 900

    6  Pages

  2. EYESTAR 900

    16  Pages

  3. OCTOPUS 600

    16  Pages

  4. OCTOPUS 900

    16  Pages

  5. SLIT LAMPS

    28  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.