HF1 Surg Bipolar Universal HF-surgery device User Manual

Open the catalog to page 1
HF1 Surg Bipolar - 4

User Manual Comments to content / scope of delivery Radio frequency (RF) – operating mode Technical data Caution and safety regulations Operator‘s ordinance Preparation to start the device / labelling Taking out of operation after use Device description / dual user conception Set up parameters in information display Selection of the correct radio frequency (RF) mode RF (radio frequency) CUT MODE RF (radio frequency) COAG MODE RF (radio frequency) BIPOLAR MODE Reprocessing guide for hand pieces Environmental policy Catalogue of error messages Clinical applications radio frequency (RF) This...

Open the catalog to page 4
HF1 Surg Bipolar - 5

User Manual Please read this user manual carefully! Read this user manual completely and familiarise yourself with the use and functions of the device and all of its accessories, before you start using the device. Should you fail to follow the instructions, the following problems may occur: • Serious injuries to the patient • Serious injuries to the operator or to the service personal • Damage of malfunction of the unit or of the accessories Intended purpose The radio-frequency device HF1 Surg Bipolar is used in dental surgery of the soft tissue and is suitable for the following purposes:...

Open the catalog to page 5
HF1 Surg Bipolar - 6

User Manual Explanations to the user manual Important directives, especially for technical safety and security, are mentioned: ATTENTION This information advices to special service procedures or caution measures, which must be considered to avoid damage to the device. REMARK This is general and special information to clarify important and helpful instructions. Scope of Delivery HF1 Surg Bipolar - REF 452 459 HF set of instruments, 6 pcs HF hand piece Yellow 1.50 m HF hand piece Blue 1.50 m Neutral electrode Foot pedal User manual Medical product journal (Bipolar forceps optional)

Open the catalog to page 6
HF1 Surg Bipolar - 7

User Manual Principle of operation of radio frequency (RF) If radio frequency is guided through very thin metal electrodes, a very large electro-magnetic power density is created in the tissue layer. The water is abruptly heated up in these cells which leads to cooking and rupture, respectively. THERMAL OPERATION (MONOPOLAR) CUTTING (CUT) / COAGULATION (COAG) At monopolar cutting the radio frequency current is led from the device via a work electrode and a large neutral electrode back to the device. The current density at the treatment point is very high, but it is very low at the neutral...

Open the catalog to page 7
HF1 Surg Bipolar - 8

User Manual Technical Data HF Monopolar 2.2 MHz max. 50 W load resistance 1000 ohm Bipolar 2.2 MHz max. 46 W load resistance 250 ohm Coagulation 2.2 MHz max. 45 W load resistance 1000 ohm permanently / pulsed Operating temperature Storage temperature When in operation: <85%, non-condensing When not in operation: <90%, non-condensing When in operation: 700 hPa - 1080 hPa When not in operation: 500 hPa - 1080 hPa Power supply 230 V AC, 50/60 Hz Unplug the power plug for an all-pole disconnection of the device. Power consumption Power fuse Medical device classification Hand piece...

Open the catalog to page 8
HF1 Surg Bipolar - 9

User Manual Protection and safety provisions in the dental practice for the use of radio frequency surgery of the HF1 Surg Bipolar device The HF1 Surg Bipolar device may only be put into operation after the instructions have been given by the operator and in compliance with the prescriptions and safety provisions. WARNING The device must only be connected to a power supply with an earth wire in order to avoid the risk of an electric shock. Check the cables, hand piece and electrodes as well as the foot pedal on visible damage before starting up the HF1 Surg Bipolar device. Instruments with...

Open the catalog to page 9
HF1 Surg Bipolar - 10

User Manual Operator regulation According to Council Directive 93/42/EEC, the device is classified as medical device unit class IIb. Thus all directions of the European operator regulation apply. Technical controls: The user is committed to perform technical controls on a regular basis conforming to the following specifications: Period: Every 24 months, starting with the date of delivery and after each repair. Covering: Visual check of the unit and accessories Check according to IEC 62353 (VDE 0751) - Protective earth resistance - Alternate leakage current - Alternate patient leakage...

Open the catalog to page 10
HF1 Surg Bipolar - 11

User Manual Preparation to start the device • In order to avoid condensed water, make sure the device has been at room temperature for at least 30 minutes before you use it. Start up • Connect foot switch with device. • First of all connect the power supply cable to the device, then connect it to the house power output. • Equip the RF-handpieces with the appropriate electrode, by slightly loosening the handle tip. • Put the hand pieces in the receptacles and connect the radio frequency (RF) cable to the device. Please pay attention to the marks (coloured). • Connect the neutral electrode. •...

Open the catalog to page 11
HF1 Surg Bipolar - 12

User Manual Front 1. Receptacles radio frequency (RF) 2. Display (touch screen) 3. Neutral electrode 4. Output HF CUT 7. Output HF BIPOL 8. Output HF COAG Back 1. Foot switch 2. Type label 3. 230 V Power supply and main switch Dual User Conception: It is possible to choose every single application (mode) by using the touch screen as well as by using the receptacles (except BIPOLAR). For safety reasons the simultaneous selection of a mode via touch screen or via tubular switch is intended in the following way: • Whenever a mode operation button is coloured, the mode can be selected and...

Open the catalog to page 12
HF1 Surg Bipolar - 13

User Manual Standard hand piece HF-electrode COAG Neutral electrode

Open the catalog to page 13
HF1 Surg Bipolar - 14

User Manual Start Start the device by using the power switch at the back of the device. With acceptance of the user code the main menu will appear: CUT BIPOL COAG Information Software Version The following options are available: • Go to information menu by pressing the button in the right upper corner • Mode selection by buttons – pressing one of the coloured buttons directly leads to a mode. If a mode selection button is GREY, this is not possible as another mode is active. • Mode selection by receptacle – by taking the hand piece out of the receptacle the according mode will be selected,...