1. Catalogs
  2. Haier Biomedical
  3. Ductless Fume Hood HTF-1200W/1500W

Ductless Fume Hood HTF-1200W/1500W

Ductless Fume Hood HTF-1200W/1500W

Ductless Fume Hood HTF-1200W/1500W

Product catalog summary
Scope of Application
Haier Biomedical's Ductless Fume Hood is designed to protect laboratory personnel and the environment from toxic chemical fumes, odors, and particles using carbon filtration. It is applicable in various fields such as universities, public health, chemical and petrochemical industries, drug testing, and museums.
Innovative Design
The fume hood offers a range of accessories and options to meet diverse client requirements. It features an intelligent constant speed design for optimal filter adsorption, multiple stackable filter types for handling different chemicals, and an energy-efficient EC fan for reliable operation.
Key Features
  • Intelligent constant speed design for effective filter adsorption.
  • Standard VOC sensor for detecting volatile organic compounds and indicating filter saturation.
  • Multiple stackable filter types for removing vapor contaminants.
  • Energy-efficient EC fan for longer service life.
  • 10-inch touch screen for real-time display of VOC concentration, wind speed, filter service life, and UV lamp running time.
  • PIR detection for energy-saving mode when the area is clear of personnel.
  • Waterproof electrical sockets with timing technology.
  • Air velocity sensor for stability.
  • Universal casters with built-in threaded support legs.
  • UV lamp, electrically operated glass sash, height adjustable stand, dual surveillance cameras, IoT module, and PVC worktable.
Specifications
  • Microprocessor control system and tempered glass sliding sash window.
  • EC fan and multiple filter options including standard, organic solvent, acid gas, alkaline gas, formaldehyde, and particle filters.
  • Power supply: 220V/50/60Hz, Power: 1200-1300W, Sound level: ≤58 dB(A).
  • Inflow air velocity: 0.4-0.6 m/s, Fluorescent light intensity: ≥1000 lux.
  • Exterior dimensions: 1336-1636mm (W) x 780mm (D) x 2120mm (H).
  • Net weight: 230-250 Kg, Packaging weight: 290-330 Kg.
  • 10-inch display, standard VOC sensor, CE certification.
Types of Filters
  • Standard Filter: Mixed with N4A1, N4B1, and N4G1 activated carbon for general laboratory chemicals.
  • Organic Solvent Filter: N4G1 activated carbon for toluene, benzene, xylene, etc.
  • Acid Gas Filter: N4A1 activated carbon for hydrochloric acid, sulfuric acid, etc.
  • Alkaline Gas Filter: N4B1 activated carbon for ammonia, amine, etc.
  • Formaldehyde Filter: For formaldehyde adsorption.
  • Particle Filter: For dust absorption.
See more

Catalog excerpts

Ductless Fume Hood HTF-1200W/1500W-1

Ductless Fume Hood Scope of Application Haier Biomedical Ductless Fume Hood utilizes carbon filtration to protect laboratory personnel and the environment from toxic chemical fumes, odours, and particles. It is widely used in universities, public health, chemical and petrochemical industry, drug testing, museums and many other fields which involve the use of chemicals Intelligent Constant Speed Design Innovative Design Standard VOC sensor detects presence of volatile organic compounds in the exhaust and alarms to indicate filter saturation Multiple Stackable Filter Types Offers a broad range of accessories and options to meet clients’ different requirements Biomedical Co.,Ltd.

 Open the catalog to page 1
Ductless Fume Hood HTF-1200W/1500W-2

Ductless Fume Hood Key Features Intelligent constant speed design, ensures the best adsorption effect of the filter Energy-efficient EC fan for a longer service life and reliable operation Offers a broad range of accessories and options to meet clients’ different requirements Standard VOC sensor detects presence of volatile organic compounds in the exhaust and alarms to indicate filter saturation Multiple stackable filter types: remove vapor contaminants from the air, can be combined to handle different types of chemicals and particulates during the same application Product Details 10-inch touch screen...

 Open the catalog to page 2
Ductless Fume Hood HTF-1200W/1500W-3

Ductless Fume Hood 1.Microprocessor Control System 2.Tempered Glass Sliding Sash Window 3.EC fan 4.First filter 5.Second filter(optional) 6.VOC sensor 7.Temperature and humidity sensor 8.Wind velocity sensor 9.Tempered Glass Side 10.Electrical sockets(2 on each side) 11.Powder coated steel worktop Types of Filters Carbon filters are used to remove toxic gases, hazardous fumes, and odors. These filters are constructed from high-quality carbon pellets and durable chemical-resistant cases. Below is Haier Biomedical filters list Code No Suitable Applications Standard Filter (Mixed with N4A1, N4B1 and...

 Open the catalog to page 3

All Haier Biomedical catalogs and technical brochures

  1. Haier Bio-2T

    2  Pages

  2. Haier RTMD

    2  Pages

  3. Haier HXC-158

    2  Pages

  4. Haier RFID

    2  Pages

  5. Haier HYC-410

    4  Pages

  6. Haier HYC-290

    2  Pages

  7. HYC-361

    2  Pages

  8. HYC-61

    2  Pages

  9. HYC-1378

    2  Pages

  10. HYC-940

    2  Pages

  11. HYC-940F

    2  Pages

  12. HYC-610

    2  Pages

  13. HYC-509R

    2  Pages

  14. HYC-410

    4  Pages

  15. HYC-390R

    2  Pages

  16. HYC-390F

    2  Pages

  17. HYC-390

    2  Pages

  18. HYC-290

    2  Pages

  19. HYC- 68 68A

    2  Pages

  20. DW-86L100J

    4  Pages

  21. Air Purifier

    2  Pages

  22. DW-30L818BP

    2  Pages

  23. DW-30L818

    4  Pages

  24. LHW series

    2  Pages

  25. CO2 Incubator

    4  Pages

  26. YDD-850-465

    25  Pages

  27. HYCD-282A

    2  Pages

  28. HYCD-469

    2  Pages

  29. HYCD-282

    2  Pages

  30. DW-150W200

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.