Overview: The document provides comprehensive information on Haier Biomedical's liquid nitrogen storage solutions, emphasizing intelligent protection for life sciences. It details various series of storage solutions, including biobank, medium-sized, small-sized, high-capacity, and dryshipper series, each tailored for specific storage needs.
Key Features:
  • Advanced vacuum and superinsulation technology ensure temperature uniformity and reduced nitrogen consumption.
  • The Cryosmart intelligent control system offers monitoring and safety features.
  • Enhanced usability with self-diagnostics, one-touch defogging, and lockable lids.
  • A 5-year vacuum warranty and splash-proof design enhance safety.
Biobank Series:
  • Designed for large-scale storage, with capacities ranging from 13,000 to 94,875 cryovials.
  • Supports both liquid and vapor phase storage to prevent cross-contamination, maintaining temperatures at -190°C in vapor phase storage.
Storage Design:
  • Features a rotating tray design for easy sample access.
  • Storage space is divided into clearly labeled fan-shaped areas.
Performance and Testing:
  • Temperature tests indicate maintenance below -135°C for up to 22 days.
  • Graphical data illustrates performance over time for various models.
Product Specifications:
  • Detailed specifications for models such as YDD-350-326, YDD-370-326, and others, including dimensions, capacity, and weight.
Accessories and Options:
  • Various racks and cryo boxes are available for different storage needs.
  • Optional intelligent level monitoring systems enhance control.
Specifications: The document lists multiple models, each with specific storage capacities and configurations, detailing the use of vacuum insulated hoses, cryoboxes, and racks for storing vials and blood bags. It specifies dimensions, storage capacity, and static evaporation rates for different models.
Procedures and Usage: Systems are designed for differential pressure measurement in gas-phase liquid nitrogen containers, featuring vacuum insulated hoses and cryosmart level monitoring systems. The document outlines the use of racks and cryoboxes for efficient sample organization and storage.
Recommendations and Best Practices: The document suggests using the systems for long-term cryopreservation, highlighting compatibility with various cryobox brands and the ability to maintain ultra-low temperatures. It recommends smart series racks for efficient storage and management.
Technical Parameters: Detailed technical parameters are provided for each model, including the number of racks, storage capacity for cryovials, liquid nitrogen volume, and static holding time, emphasizing their importance for optimal performance and sample safety.
Accessories: Various accessories such as caster bases, smart boxes, and lockable caps enhance the functionality and security of the storage systems.
Monitoring Systems: The SmartCap and U-cool Monitoring System allow real-time monitoring of liquid nitrogen levels and temperature, with data transmission capabilities to a cloud platform. Users can access data via Haier's U-cool platform and receive updates through email and WeChat.
Product Advantages:
  • Innovative design utilizes vaporization pressure for LN2 discharge.
  • Digital display and remote data transmission capabilities enhance monitoring and control.
  • Pressure stabilizing valves and rapid relief of overpressure ensure safety and efficiency.
See more

Catalog excerpts

YDD-850-465-1

North America Middle East South East Asia South America Oceania LIQUID NITROGEN STORAGE SOLUTIONS Qingdao Biomedical Co.,Ltd. No.280 Feng Yuan Road, High-tech Zone, Qingdao, 266109, P.R. China Tel: +86-0532-88935955 Website: www.haiermedical.com Haier Biomedical International Haier Biomedical International Haier Biomedical International Intelligent Protection of Life Science Haier Biomedical International Note:If a slight difference occurs between pictures and actual products, please refer to actual products. Our company reserves the right of final interpretation of this brochure, please contact us for any further information if required. The models, parameters and performance in the brochure are subject to change due to product upgrades without prior notice.

 Open the catalog to page 1
YDD-850-465-2

LIQUID NITROGEN STORAGE SOLUTION Haier YDD-B5D-465 Extra large LCD and cryogenic intelligent management establishing a new global standard © Biobank Series for Large Scale Storage © Smart Series (Square Racks) © Medium Sized Storage Series (Square Racks) © Small Sized Storage Series (Square Racks) © High Capacity Series for Storage or Transport (Round Canisters) © Dryshipper Series for Transportation (Round Canisters) © Self-pressurized Series for LN2 Storage and Supply

 Open the catalog to page 2
YDD-850-465-3

Haier Biomedical Liquid Nitrogen Storage System Intelligent Protection of Life Science Biobank Series for Large Scale Storage Key Features Biobank series for large scale storage is designed to ensure the maximum storage capacity with the minimum consumption of liquid nitrogen to lower the overall cost of operation. • LN2 Splashproof • Data Logging • Hot Gas Bypass • Self-diagnostics • Vapour Phase Storage • Lockable Lid • 5 Year Vacuum Warranty • Liquid Phase Storage• From 13,000 to 94,875 Cryovials • One-touch Defogging Haier YD D-1 saa-63 5 • Massive capacity between 13,000 to 94,875x2ml Vials...

 Open the catalog to page 3
YDD-850-465-4

Haier Biomedical Liquid Nitrogen Storage System Intelligent Protection of Life Science Cryosmart intelligent LN2 control system to ensure samples safety Advanced vacuum system and superinsulation Rotating tray design for easy retrieval and insertion of storage racks Vapour condensation near the container opening is controlled. Reducing the amount of water vapour solidification on the outer surface of the neck. This unique design of the opening strengthens the structure of the tank under a full load, helping to extend its service life. Temperature Test Graph Small self-pressurized liquid nitrogen...

 Open the catalog to page 4
YDD-850-465-5

t Haier Biomedical Liquid Nitrogen Storage System Intelligent Protection of Life Science Technical Parameters Maximum Storage Capacity 2 ml Vials (Internal Thread) Inside Neck Diameter (mm)

 Open the catalog to page 5
YDD-850-465-6

t Haier Biomedical Liquid Nitrogen Storage System Intelligent Protection of Life Science Square Canister & Racks Layout Vertical racks Product List Liquid Nitrogen Storage Solution

 Open the catalog to page 6
YDD-850-465-7

Haier Biomedical Liquid Nitrogen Storage System Intelligent Protection of Life Science Product List Product List Liquid Nitrogen Storage Solution

 Open the catalog to page 7
YDD-850-465-8

Haier Biomedical Liquid Nitrogen Storage System Intelligent Protection of Life Science Product List Biological Sample Bank-YDD Series Storage Example of 2ml Internally Threaded Vial Storage Example of Tall 5ml Cryovials Blood Bag Storage Example Straw Storage Example

 Open the catalog to page 8
YDD-850-465-9

Intelligent Protection of Life Science Haier Biomedical Liquid Nitrogen Storage System Smart Series (Square Racks) Key Features • Cloud data storage for traceability • 5 years vacuum warranty • Durable aluminium construction The smart, IoT and cloud management system monitors temperature and liquid levels simultaneously to provide accurate and real-time information on the critical parameters to ensure ultimate sample safety. • 5 models from 2,400 to 6,000 cryovial capacity • Low consumption rate and high performance stability • New lock design • Real time monitor of temperature and fluid level...

 Open the catalog to page 9
YDD-850-465-10

t Haier Biomedical Liquid Nitrogen Storage System Intelligent Protection of Life Science Technical Parameters Medium Sized Storage Series (Square Racks) r Model * Static evapouration and static holding time are theoretical values. Actual evapouration and holding time are affected by usage, atmospheric conditions, and manufacturing tolerances. ** Static Holding Time: the amount of days it takes for all of the LN to evapourate out after container is filled with liquid nitrogen to pre-cool and reach thermal equilibrium and the liquid nitrogen filling rate reaches 100% under standard atmospheric...

 Open the catalog to page 10
YDD-850-465-11

Haier Biomedical Liquid Nitrogen Storage System Intelligent Protection of Life Science Technical Parameters Key Features • Heavy duty lockable enclosure offers excellent security • Compatible with all major cryobox brands • Durable aluminium construction • Temperature monitoring available Neck Opening Diameter (mm) * Static evapouration and static holding time are theoretical values. Actual evapouration and holding time are affected by usage, atmospheric conditions, and manufacturing tolerances. ** Static Holding Time: the amount of days it takes for all of the LN to evapourate out after container...

 Open the catalog to page 11
YDD-850-465-12

t Haier Biomedical Liquid Nitrogen Storage System Intelligent Protection of Life Science Product List Model

 Open the catalog to page 12
YDD-850-465-13

Intelligent Protection of Life Science Haier Biomedical Liquid Nitrogen Storage System Small Sized Storage Series (Square Racks) Biological Sample Library-YDS Series Widely used within many laboratories, this small-sized storage series features low LN₂ consumption and dual handle design. Stores between 600 and 1100 vials in square racks and cryo boxes. Storage Example of 2ml Internally Threaded Vial • 5 Year Vacuum Warranty • High Thermal Eff iciency Plastic Cryobox (25, 81, 100) Vertical Freezing Rack • 30 Litre to 50 Litre Capacity Storage Example of Tall 5ml cryovials Blood Bag Storage Example...

 Open the catalog to page 13
YDD-850-465-14

Haier Biomedical Liquid Nitrogen Storage System Intelligent Protection of Life Science Technical Parameters Key Features Model Maximum Storage Capacity Roller bases available High thermal efficiency 5 year vacuum warranty Ultra-low LN2 evapouration loss • Heavy duty lockable enclosure offers excellent security • Strong, lightweight aluminium construction • Dual handles • Temperature monitoring available * Static evapouration and static holding time are theoretical values. Actual evapouration and holding time are affected by usage, atmospheric conditions, and manufacturing tolerances. ** Static...

 Open the catalog to page 14

All Haier Biomedical catalogs and technical brochures

  1. Haier Bio-2T

    2  Pages

  2. Haier RTMD

    2  Pages

  3. Haier HXC-158

    2  Pages

  4. Haier RFID

    2  Pages

  5. Haier HYC-410

    4  Pages

  6. Haier HYC-290

    2  Pages

  7. HYC-361

    2  Pages

  8. HYC-61

    2  Pages

  9. HYC-1378

    2  Pages

  10. HYC-940

    2  Pages

  11. HYC-940F

    2  Pages

  12. HYC-610

    2  Pages

  13. HYC-509R

    2  Pages

  14. HYC-410

    4  Pages

  15. HYC-390R

    2  Pages

  16. HYC-390F

    2  Pages

  17. HYC-390

    2  Pages

  18. HYC-290

    2  Pages

  19. HYC- 68 68A

    2  Pages

  20. DW-86L100J

    4  Pages

  21. Air Purifier

    2  Pages

  22. DW-30L818BP

    2  Pages

  23. DW-30L818

    4  Pages

  24. LHW series

    2  Pages

  25. CO2 Incubator

    4  Pages

  26. HYCD-282A

    2  Pages

  27. HYCD-469

    2  Pages

  28. HYCD-282

    2  Pages

  29. DW-150W200

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.