Overview: The HAMILTON-T1 is a transport ventilator that combines ICU ventilator functionality with the compactness needed for transport. It is suitable for adult, pediatric, and neonatal patients and is approved for use in ambulances, helicopters, and airplanes.
Specifications: The ventilator is independent of compressed air, has up to 9 hours of battery life, and supports noninvasive ventilation and high flow oxygen therapy. It includes advanced ventilation modes like ASV® and INTELLiVENT®-ASV, and features CPR ventilation.
Approvals and Standards: The HAMILTON-T1 meets various transport standards including EN 794-3, ISO 10651-3, EN 1789, EN 13718-1, RTCA/DO-160G, and IEC 60601-1-12, ensuring its reliability across different transport scenarios.
Features: The ventilator offers flexible mounting options, a user-friendly interface, and a Ventilation Cockpit for monitoring. It supports real-time patient synchronization with IntelliSync+ and includes options like a high-performance turbine, hot-swappable battery, and integrated nebulizer.
Neonatal Care: The HAMILTON-T1 provides state-of-the-art ventilation therapy for newborns, including noninvasive and invasive modes, leak compensation, and specific monitoring parameters. It is compatible with transport incubators for seamless neonatal care.
Ease of Use: Designed with input from users and experts, the ventilator's interface is intuitive, allowing easy switching between different Hamilton Medical ventilators. The customizable display and direct access to controls enhance usability.
Training and Support: The HAMILTON-T1 Learning Hub and VenTrainer App offer educational resources to help users familiarize themselves with the ventilator's features and use them effectively in simulated scenarios.
Manufacturer Information: Hamilton Medical AG, based in Switzerland, is the manufacturer. The product is intended for healthcare professionals and is not available for general public purchase.
See more

Catalog excerpts

HAMILTON-T1 EMS brochure-1

Confident ventilation for critical care transports

 Open the catalog to page 1
HAMILTON-T1 EMS brochure-2

The HAMILTON-T1 is the first transport ventilator that combines the functionality of a fully featured ICU ventilator with the compactness and ruggedness required for transport. This combination enables you to provide optimal ventilation therapy to all patient groups during transport. Approvals and certificates for use in ambulances, helicopters and airplanes Adult, pediatric, and neonatal ventilation Independence from compressed air Up to 9 hours of battery operating time Noninvasive ventilation and integrated high flow oxygen therapy* Advanced ventilation modes, including ASV® and INTELLiVENT®-ASV...

 Open the catalog to page 2
HAMILTON-T1 EMS brochure-3

Designed for mobility and convenient transport Approved for all types of transport The HAMILTON-T1 meets the transport standards EN 794-3 and ISO 10651-3 for emergency and transport ventilators, EN 1789 for ambulances, EN 13718-1 and RTCA/DO-160G for aircraft, as well as IEC 60601-1-12 for basic safety and essential performance. It reliably accompanies your patients to any destination either within or outside of the hospital, on the ground, at sea, and in the air. Independent from compressed air The integrated high-performance turbine enables the HAMILTON-T1 to be completely independent from...

 Open the catalog to page 3
HAMILTON-T1 EMS brochure-4

In close cooperation with users and ventilation experts, our engineers have designed the user interface to be particularly intuitive. Switching between the HAMILTON-T1 and all other Hamilton Medical ventilators is easy, because they are all operated according to the same principles. The Ventilation Cockpit on the HAMILTON-T1 consolidates the monitoring data and displays it as advanced graphics. These provide a quick overview of the patient’s current ventilation status and provide a reliable basis for therapy decisions. About 50% of our patients go onto ASV mode. It is specifically advantageous...

 Open the catalog to page 4
HAMILTON-T1 EMS brochure-5

1 Main monitoring parameters All of the main monitoring parameters at a glance. The large characters allow you to see them even from a distance. One quick look shows you tidal volume, lung compliance, patient triggering, and resistance in real-time. The lungs expand and contract in synchrony with the actual breaths. 3 Customizable user interface You can configure the display layout with different waveforms, loops, trends, or intelligent panel graphics to suit your institution's needs and protocols. Nurses and clinicians can have their own preferred layout. 4 Direct access to main controls Access...

 Open the catalog to page 5
HAMILTON-T1 EMS brochure-7

For transporting all patients, even the smallest State-of-the-art ventilation therapy for newborns Noninvasive ventilation modes and therapies developed especially for neonatal patients (synchronized noninvasive ventilation, demand-flow nCPAP modes, Volume Support mode, and high flow oxygen therapy) Invasive ventilation modes developed for neonatal patients, including volume-targeted ventilation Leak compensation in every mode Continuity of care for newborns from the delivery room to the NICU, as well as for transport In combination with a transport incubator, it represents an advanced solution...

 Open the catalog to page 7
HAMILTON-T1 EMS brochure-8

Features and options Oxygen adjustable from 21% to 100% allows you to replicate the bedside settings one-to-one during transport. The adjustment to 21% even makes it possible to ventilate your patient with ambient air only. CPR ventilation adapts ventilation settings to situations where CPR is being performed. It supports the CPR workflow with quick access to preconfigurable settings, adequate alarm and trigger adjustment, CPR-timer display, and display of the relevant main monitoring parameters and curves. Integrated high flow oxygen therapy can be applied using the same device and breathing...

 Open the catalog to page 8
HAMILTON-T1 EMS brochure-9

Features and options Adult, pediatric, and neonatal ventilation Configurable loops and trends High-performance turbine Compatible with conventional speaking valves Hot-swappable battery backup Night vision goggles (NVG) Serial interface for connection to PDMS or patient monitors Approval for all types of transport Mainstream (volumetric) and sidestream capnography Real-time patient synchronization with IntelliSync+ Pulse oximetry (SpO2 and pulse measurement) INTELLiVENT-ASV for bedside assistance nCPAP modes Integrated pneumatic and optional Aerogen nebulizer

 Open the catalog to page 9
HAMILTON-T1 EMS brochure-10

The HAMILTON-T1 Learning Hub offers step-by-step learning paths to help you quickly get to know your ventilator and its features. Test your new knowledge on our interactive VenTrainer App, and use your ventilator and its features savely in simulated patient scenarios.

 Open the catalog to page 10
HAMILTON-T1 EMS brochure-12

Manufacturer: Hamilton Medical AG Via Crusch 8, 7402 Bonaduz, Switzerland +41 (0)58 610 10 20 [email protected] www.hamilton-medical.com The products shown here are not available for purchase by the general public. The information provided here is intended for healthcare professionals only. Always read the labels and follow the product’s instructions for use. Specifications are subject to change without notice. Some features are options. Not all features are available in all markets. All images are used for illustrative purposes only and may not accurately represent the product or its...