Patient interventions during transport are not always possible. The HAMILTON-T1’s nCPAP mode is designed in such a way that you only need to set the desired CPAP pressure. The flow is subsequently adjusted automatically based on the patient condition and variation in leakage, which prevents unintended peak pressures and guarantees highly efficient leak compensation. Flow adjustment occurs with a minimum of delay due to the highly sensitive, proximal pressure measurement. Free breathing in each ventilation phase In addition to the standard nCPAP mode, the HAMILTON-T1 also features the biphasic nCPAP-PC (pressure controlled) mode. This mode allows you to set two pressure levels as well as the rate and inspiratory time. The flow is also adjusted as needed in this mode. The modern pneumatic concept of the HAMILTON-T1 additionally enables the patient to breathe freely at any time on both pressure levels. The leak compensation function in the HAMILTON-T1 is outstanding and superior to normal intensive care ventilators. The synchronization of the patient is very good at all times, even if the leak is extensive. Dr. Süha Demirakça, Senior Physician PICU & Pulmonology Clinic for Pediatric Medicine, Mannheim, Germany Hamilton Medical AG Via Crusch 8 7402 Bonaduz, Switzerland HAMILTON-T1 Intelligent transport ventilation for neonates * Optional, not available in all markets nCPAP - Automatic adaptation, fewer interventions 689522.01 Product and order information are subject to change without notice. Not all options are available in all countries. © 2016 Hamilton Medical AG. All rights reserved. nCPAP optimized for transport The HAMILTON-T1 is an intelligent transport ventilator that provides ventilation therapy for your smallest and most fragile patients during transport. Thanks to its unique properties, the HAMILTON-T1 performs during transport like a fully featured NICU ventilator at the bedside: Conventional and modern ventilation modes for neonates Noninvasive ventilation and integrated high flow oxygen therapy* Tidal volumes as low as 2 ml Optimal synchronization using proximal flow sensor Independence from gas cylinders or compressors due to the integrated high-performance turbine More than 9 hours of battery operating time without battery rep

 Open the catalog to page 1
HAMILTON-T1 with neonatal function brochure-2

Optimized performance for neonates Unlimited mobility Approved for all types of transport With the neonatal option, the HAMILTON-T1 provides tidal volumes as low as 2 ml for effective, safe, and lung-protective ventilation even for the smallest patients.1) The proximal flow sensor specifically developed for neonates precisely measures the pressure, volume, and flow directly at the infant’s airway opening, ensuring the required trigger sensitivity. This provides improved synchronization and less work of breathing. The HAMILTON-T1 meets the transport standards EN 794-3 and ISO 10651-3 for emergency...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.