1. Catalogs
  2. Hamilton Process Analytics
  3. VisiFerm DO SU Arc 120 C

VisiFerm DO SU Arc 120 C

VisiFerm DO SU Arc 120 C

VisiFerm DO SU Arc 120 C

Product catalog summary
Product Overview: The VisiFerm DO SU Arc 120 C is designed for single-use applications and works with the Hamilton Single Use ODO Cap. It is reusable and can be mounted directly into the ODO Cap within a bag or SU bioreactor.
Product Specifications:
  • Sensor Family: Visiferm SU
  • Length: 120 mm
  • Electrical Connector: VP8
  • Sensor Output: Arc: Modbus, 4 to 20 mA
  • Measurement Principle: Oxygen-dependent luminescence quenching with temperature compensation
  • Measuring Range: 4 ppb to 25 ppm (DO), 0 to 62.85 %-vol, 0 to 300 %-sat
  • Accuracy at 25°C: ±1.0 %-sat at 20 %-sat, ±1.0 %-sat at 100 %-sat, ±2.5 %-sat at 200 %-sat (only with gamma irradiated Hamilton single-use ODO Cap and product calibration)
  • Drift at Room Temperature: < 1 % per week
  • Electrolyte: None
  • Oxygen Consumption: None
  • Temperature Sensor: NTC 22 kOhm
  • Configurable Values: DO: mbar, %-sat, %-vol, µg/l, mg/l, ppb/ppm (gas), ppb/ppm (dissolved oxygen); Temperature: °C
  • Diameter: 12 mm
  • Analog Interface: 4 to 20 mA for DO, programmable, not galvanically isolated; pulse width modulation 5 kHz
  • Digital Interface: RS485 Modbus (max. 31 addresses)
  • Baud Rate: 4800, 9600, 19200, 38400, 57600, 115200 Bd
  • Operating Voltage: 7 to 30 VDC max. 1 W
  • Serial Number: Yes
  • Response Time: t98% < 30 s at 25°C
  • Certificate: Yes, with parameter settings and materials used
  • ATEX Approval: No
  • Autoclavable: No
  • CIP: No
  • Steam Sterilizable: No
  • Gamma Irradiatable: No
  • Operating Temperature Range: 0 to 60°C
  • Required Flow: None
Additional Information: Specifications are subject to change without notice. For more details, visit the Hamilton Company website.
See more

Catalog excerpts

VisiFerm DO SU Arc 120 C-1

VisiFerm DO SU Arc 120 CSpecification Sheet (Part/REF # 10078255) The VisiFerm DO for single use applications works with Hamilton Single Use ODO Cap . The VisiFerm is reusable and can be mounted directly into the ODO Cap within the bag or SU bioreactor. Sensor Family Visiferm SU Sensor Output Arc: Modbus, 4 to 20 mA Measurement Principle Oxygen dependent luminescence quenching, temperature compensation Accuracy at 25 °C ± 1.0 %-sat (at 20 %-sat), only in combination with the gamma irradiated Hamilton single-use ODO Cap and with product calibration ± 1.0 %-sat (at 100 %-sat), only in combination with the gamma irradiated Hamilton single-use ODO Cap and with product calibration ± 2.5 %-sat (at 200 %-sat), only in combination with the gamma irradiated Hamilton single-use ODO Cap and with product calibration Drift at Room Temperature < 1 % per week (of measurement value) Electrolyte None Oxygen Consumption None Temperature Sensor NTC 22 kOhm Configurable Values DO: mbar; %-sat; %-vol; pg/l; mg/l; ppb/ppm (gas); ppb/ppm (dissolved oxygen); Temperature: °C Analog Interface 1 4 to 20 mA for DO, programmable, galvanically not isolated; pulse width modulation 5 kHz Digital Interface RS485 Modbus (max. 31 addresses) Certificate Yes, with parameter settings and materials used Operating Temperature Range 0 to 60 °C

 Open the catalog to page 1
VisiFerm DO SU Arc 120 C-2

Required Flow None Specifications are subject to change without notice Spec. Version D

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.