Warnings, Precautions and Safety Information Feline Blood Typing Rapid Test(F-BT A+B) TEST PROCEDURE 1. The test device is used for feline only. 2. The results may be influenced by humidity and temperature. 3. Make sure that the foil pouch containing the test is not damaged before open. Perform the test immediately Type A : If the C line and the A line show color while the B line does not show color, then the blood type is determined to be “Type A”. when the pouch package is opened. 4. Do not reuse the test components. 5. Do not use after the expiry date. 6. Do not mix product components in different lot numbers. 7. As all samples are potentially infectious. Operators Blood transfusion therapy is the best treatment for should wear protective gloves while handling samples anemia caused by various reasons, and blood type is and wash hands thoroughly afterwards. the primary factor to consider in transfusions. 8. Decontaminate and dispose of all samples, used kits Mismatched blood types between the donor and the and potentially contaminated materials safely in recipient can trigger a transfusion reaction, which, in accordance with national and local regulations. Use a sampling pipe to draw some whole blood specimens (approximately 10 µL) through the capillary effect. If the hematocrit is below 20%, it is recommended to use a pipette to add an additional 10 μL of whole blood sample to the buffer. Type B : If the C line and the B line show color while the A line does not show color, then the blood type is determined to be “Type B”. Type AB : If the line C,B,A show color all together, then the blood type is determined to be “Type AB”. Invalid : No colored line appears in C region. severe cases, may lead to death. Additionally, if a newborn kitten's blood type does not match that of its mother, the kitten may absorb antibodies from the colostrum, causing hemolytic anemia, which could also be fatal. Cats naturally possess antibodies against different blood types. Type A cats have low titers of anti-B Specimen Collection, Handling, and Transport 1.This product is applicable for fresh whole blood/anti- antibodies, most of which are IgG. Type B cats, on the coagulated venous whole blood. other hand, have high titers of anti-A IgM antibodies. 2.Whole Blood: Collect whole blood samples using EDTA AB-type cats are immunotolerant to both antigens and anticoagulation. If the whole blood samples are not therefore do not have any antibodies in their system. tested immediately, they should be refrigerated at 2-8°C F-BT(A+B) is intended for use to classify cats as blood and used within 24 hours, and must not be frozen. group Type A, Type B or Type AB. Peel off aluminum foil seal from the top of the extraction tube containing the extraction buffer,insert sampling end into pipe and cover tightly,mixed completely. batch code contains sufficient for tests in vitro diagnotic medical device temperature limitation 3.Hemolyzed or contaminated samples may lead to Hangzhou Antigenne Technology Co., Ltd erroneous results. Address:Block A, Building 3, No. 8, Xiyuan 9th Road, Xihu District, Hangzhou, Zhejiang, 310030 P.R. China Reagent and Materials Provided · Test devices · Sampling pipes · Buffer tubes · Package insert CHECK THE KIT CONTENTS BEFORE USE Holding the sampling pipe upright, carefully take off the cap of sampling pipe, transfer 3 drops to the specimen well (S) of the test device. If the test does not run, you may add one more drop. Materials Required but not Provided C B A INTERPRETATION OF TEST RESULT Storage and Stability The test device is sealed and should be stored away Test device Sampling pipe Buffer tube Package insert from light at a room temperature (4-30℃). Do not freeze. The test device should be used before the expiration date marked on the package label. Check the product components and ensure that the operation is carried out at room temperature (15-30°C). After 10 minutes, interpret
Open the catalog to page 11 Page
1 Page
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
28 Pages
1 Page
1 Page
2 Pages