F.IgE

F.IgE

Product catalog summary
Intended Use: The Feline Total IgE Rapid Test is a chromatographic immunoassay kit designed for the rapid detection of Feline IgE in serum or plasma from cats. It is a qualitative test card based on immunochromatography.
Principle: The test detects feline allergen-specific IgE antibodies. When a sample is added, it moves along a nitrocellulose membrane with a gold-labeled reagent. If IgE antibodies are present, they bind with the reagent, showing a purplish-red color on the test line. The control line will also show a red band.
Test Procedure: 1. Check kit contents and ensure room temperature (15-30°C). 2. Use a sampling pipe to draw approximately 10 µL of serum or plasma. 3. Mix with extraction buffer and transfer 3 drops (approximately 90 µL) to the specimen well of the test device.
Interpretation of Test Results: - Negative (-): Only the C line appears. - Positive (+): Both C and T lines appear. - Invalid: No colored line appears in the C region.
Limitations: The test is for feline use only. Results may be affected by humidity and temperature. False results may occur, and further clinical or laboratory tests may be required for confirmation.
Warnings and Precautions: - Do not reuse test components. - Do not use after the expiry date. - Handle samples as potentially infectious. - Dispose of all materials safely according to regulations.
Specimen Collection and Handling: Use serum or plasma. Store samples at 2~8°C or freeze at ‐20°C for longer storage. Avoid repeated freezing and thawing. Clarify samples with precipitate before testing.
Storage and Stability: Store the test device at room temperature (4-30°C) away from light. Do not freeze and use before the expiration date.
See more

Catalog excerpts

F.IgE-1

Warnings, Precautions and Safety Information Feline Total IgE Rapid Test (F.IgE) Check the product components and ensure that the operation is carried out at room temperature (15-30°C). Positive (+): The presence of both C line and T line, regardless of T line being strong or faint. 1. The test device is used for feline only. 2. The results may be influenced by humidity and temperature. TEST PROCEDURE 3. Make sure that the foil pouch containing the test is not damaged before open. Perform the test immediately Negative (-): Only clear C line appears. when the pouch package is opened. 4. Do not reuse the test components. 5. Do not use after the expiry date. Intended Use Feline Total IgE Rapid Test is a chromatographic immunoassay kit for rapid detection of Feline IgE in serum or plasma from feline. Invalid: No colored line appears in C region, regardless of T line’s appearance. numbers. 7. As all samples are potentially infectious. Operators should wear protective gloves while handling samples Use a sampling pipe to draw some serum or plasma specimens and wash hands thoroughly afterwards. 8. Decontaminate and dispose of all samples, used kits The Feline Total IgE Test Kit is a qualitative test card. This and potentially contaminated materials safely in test is based on the principle of immunochromatography. accordance with national and local regulations. (approximately 10 µL) through the capillary sample well, it moves along the nitrocellulose membrane with the gold-labeled reagent. If the sample contains This test aimed to the detection of feline IgE in serum/ plasma.When the sample to be tested is added to the 6. Do not mix product components in different lot Although The Feline Total IgE Test is very accurate in detecting Specimen Collection, Handling, and Transport Feline IgE, a low incidence of false results may be occurred. Other clinically or laboratory tests might be required if questionable results are obtained. As other diagnostic tests, a definitive feline allergen-specific IgE antibodies, they will bind with 1 .Serum or plasma should be used with this test. the gold-labeled reagent and the antibodies on the test Serum: Collect the whole blood into the collection tube Peel off aluminum foil seal from the top of the extraction line, showing a purplish-red color. The control line will (NOT containing anticoagulants such as heparin, EDTA tube containing the extraction buffer, insert sampling end test, but should be diagnosed by the veterinarian after all clinical also show a red band as the gold-labeled reagent binds to and sodium citrate), and then stand or centrifuge whole into pipe and cover tightly,mixed completely. and laboratory findings have been evaluated. the antibodies on the control line. If the sample does not contain feline allergen-specific IgE antibodies or the level Plasma: Collect the whole blood into the collection tube is too low, no color reaction occurs or the color band is (containing anticoagulants such as heparin, EDTA and sodium citrate) and then stand or centrifuge whole blood clinical diagnosis should not be based on the result of a single to get plasma. 2.Samples should be stored at 2~8°C. Please freeze the · Test devices · Sampling pipes · Buffer tubes · Package insert Materials Required but not Provided samples at ‐20°C or below for longer storage and avoid repeated freezing and thawing. 3. Samples containing precipitate may yield inconsistent Holding the sampling pipe upright, carefully take off the test results. They must be clarified prior to assaying. cap of sampling pipe, transfer 3 drops (approximately 90 4. Hemolyzed or contaminated samples may lead to µL) to the specimen well (S) of the test device. erroneous results. Timer CHECK THE KIT CONTENTS BEFORE USE INTERPRETATION OF TEST RESULT contains sufficient for tests in vitro diagnotic medical device temperature limitation Address:Block A, Building 3, No. 8, Xiyuan 9th Road, Xihu District, Hangzhou, Zhejiang, 31 0030 P.R. China from light at a room temperature (4-30℃). Do not freeze. The test device should be used before the expiration date marked on the package label. Hangzhou Antigenne Technology Co., Ltd The test device is sealed and should be stored away Reagent and Materials Provided Test device Sampling pipe Buffer tube Package insert Read the result at 5-1 0 minut

 Open the catalog to page 1

All Hangzhou Antigenne Technology Co. Ltd catalogs and technical brochures

  1. BVDV Ag

    1  Page

  2. BVDV Ag

    1  Page

  3. BRU Ab

    1  Page

  4. FPV GIA Ag

    1  Page

  5. CDV CPV Ag

    1  Page

  6. CDV CPIV Ag

    1  Page

  7. CDV CAV Ag

    1  Page

  8. FPV FCoV Ag

    1  Page

  9. ICH Ab

    1  Page

  10. HP Ag

    1  Page

  11. GIA Ag

    1  Page

  12. FPL

    1  Page

  13. FHV Ab

    1  Page

  14. FCV Ab

    1  Page

  15. FCoV Ab

    1  Page

  16. F-BT A+B

    1  Page

  17. CRV Ag

    1  Page

  18. CAV Ag

    1  Page

  19. C.IgE

    1  Page

  20. C.FOB

    1  Page

  21. BC Ab

    1  Page

  22. FIPV Ag

    1  Page

  23. FeLV Ag

    1  Page

  24. FCoV Ag

    1  Page

  25. F.GIA Ag

    1  Page

  26. RAB Ag

    1  Page

  27. CPV Ab

    1  Page

  28. CIV Ag

    1  Page

  29. CAV-II Ag

    1  Page

  30. CAV-I Ag

    1  Page

  31. SE Ag

    1  Page

  32. BRU Ab

    1  Page

  33. FPV/FCoV Ag

    1  Page

  34. ITGen catalog

    28  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.