7. As all samples are potentially infectious. Operators should wear protective gloves while handling samples TEST PROCEDURE Although the Porcine Circovirus Antibody Rapid Test is very and wash hands thoroughly afterwards. Porcine Circovirus Antibody Rapid Test (PCV Ab) accurate in detecting Porcine Circovirus Antibody, a low 8. Decontaminate and dispose of all samples, used kits and incidence of false results may be occurred. Other clinically or laboratory tests might be required if questionable results are accordance with national and local regulations. obtained. As other diagnostic tests, a definitive clinical diagnosis should not be based on the result of a single test, but should be diagnosed by the veterinarian after all clinical and laboratory findings have been evaluated. Specimen Collection, Handling, and Transport Intended Use Porcine Circovirus Antibody Rapid Test is a lateral flow immunoassay intended for the qualitative detection of 1.Serum or plasma should be used with this test. specific antibody from Porcine Circovirus (PCV) in Serum: Collect the whole blood into the collection tube serum or plasma. The test is useful for determination of (NOT containing anticoagulants such as heparin, EDTA and sodium citrate), and then centrifuge whole blood to get serum. Plasma: Collect the whole blood into the collection Reagent and Materials Provided · Test devices · Disposable droppers · Package insert Take the test device out of the aluminum foil bag, and place it on a clean, flat table. Add three drops (about 90 μL) of serum or plasma specimens vertically into the specimen well (S) of the test device. tube (containing anticoagulants such as heparin, EDTA and sodium citrate) and then centrifuge whole blood to get plasma. 2.Samples should be stored at 2~8°C. Please freeze INTERPRETATION OF TEST RESULT the samples at ‐20°C or below for longer storage and batch code contains sufficient for tests in vitro diagnotic medical device temperature limitation avoid repeated freezing and thawing. 3.Samples containing precipitate may yield inconsis Materials Required but not Provided Timer tent test results. They must be clarified prior to assaying. 4.Hemolyzed or contaminated samples may lead to erroneous results. Read the result at 5-10 minutes. The result is invalid after 15 minutes. Hangzhou Antigenne Technology Co., Ltd The test device is sealed and should be stored away from light at a room temperature (4-30℃). Do not freeze. The test device should be used before the expiration CHECK THE KIT CONTENTS BEFORE USE Positive (+): Both the control line C and the test line T showed a red band, indicating that the titer of PCV antibody in the blood was higher than 1:40. date marked on the package label. Negative (-): The presence of a red band in control line C and the absence of color in test line T suggested a very low level of antibodies to PCV in the blood (antibody titer < 1:40). Warnings, Precautions and Safety Information 1. The test device is used for swine only. 2. The results may be influenced by humidity and 3. Make sure that the foil pouch containing the test is not damaged before open. Perform the test immediately Test device Disposable dropper Package insert when the pouch package is opened. Invalid: No colored line appears in C region, regardless of T line’s appearance. 4. Do not reuse the test components. 5. Do not use after the expiry date. 6. Do not mix product components in different lot numbers. Check the product contents and make sure the test operation is under the room temperature (15–30℃) before testing. Address:Block A, Building 3, No. 8, Xiyuan 9th Road, Xihu District, Hang
Open the catalog to page 11 Page
1 Page
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
28 Pages
1 Page
1 Page
2 Pages