Product catalog summary
Product Name: Blood Ketone Test Strip
Main Components: The test strip includes a buffer system and active reactants such as FAD-dependent dehydrogenase (<25%) and hexachloroplatinate. It also includes a code card for use with the tester.
Storage and Shelf Life: Store in a dry environment at 5℃-30℃, away from heat and humidity, and avoid direct sunlight. The shelf life is 24 months, and the strip should be used within two minutes after removal from packaging. Do not use expired strips as they may yield incorrect results.
Applicable Tester: Designed for use with the IClearVet I type blood glucose and ketone tester.
Reference Interval:
  • Normal cow: <1.2 mmol/L
  • Subclinical cow ketosis: ≥1.2 mmol/L
  • Clinical cow ketosis: >3.0 mmol/L
Sample Requirements: Fresh capillary or venous whole blood from cows, containing anticoagulants like EDTA-2 Na or sodium heparin.
Method of Calibration: Follow the test method carefully. Prepare all necessary supplies before testing. Insert the code card, collect the blood sample, insert the test strip, and add blood to the sample port. Dispose of used materials properly.
Intended Use: For in vitro quantitative measurement of blood ketone concentration in dairy cows. Veterinary use only.
Principle of Inspection: The test strip reacts with blood ketones to produce a current signal, which the tester converts into specific blood ketone concentration values.
Interpretation of Test Results: Results are expressed in mmol/L. The test range is 0-8.0 mmol/L. "HI" indicates results exceed the range. Temperature and humidity conditions must be maintained for accurate results.
Product Performance Indicators:
  • Accuracy: 95% detection error within ±0.23mmol/L for <1.5mmol/L, and within ±15% for ≥1.5mmol/L.
  • Precision: SD<0.075mmol/L for <1.5mmol/L, CV<5.0% for ≥1.5mmol/L.
Notes:
  • Do not reuse blood collection needles or test strips.
  • Dispose of used materials in a biological waste bin.
  • Ensure the sample is added to the top of the test strip.
  • Keep out of reach of children and pets.
  • Results are for clinical auxiliary diagnosis only.
Contact Information:
Manufacturer: Hangzhou Antigenne Technology Co., Ltd, located at Block A, Building 3, No. 8, Xiyuan 9th Road, Xihu District, Hangzhou, Zhejiang, 310030 P.R. China
See more

Catalog excerpts

UG-1520830225180-Instruction Manual-ITGEN-Blood Ketone Test Strip--1

Blood Ketone Test Strip[Product Name] Blood Ketone Test Strip This test strip is designed for the in vitro quantitative measurement of blood ketone concentration in fresh capillary or venous whole blood from dairy cows. Note: This product is for veterinary use only and should not be used for therapeutic drug adjustment without professional guidance. The reaction chamber of the disposable test strip contains enzymes and electron transfer substances. When the sample is sucked in, the reagent system reacts with blood ketones in the sample and produces a current signal that is strongly correlated with the sample. The tester can convert the detection flow signal through the graphical software system into specific values of blood ketone concentration. The size of the current is proportional to the concentration of ketones. • Test strip: It consists of structural substrate, ink,good buffer system and active reactants. The 25 products include FAD-dependent dehydrogenase <25%, hexachloroplatinate. • Code card • The test strip should be stored in a dry environment of 5°C-30°C away from heat source and humid environment, and avoid direct sunlight. • The shelf life of the well-packaged test strip is 24 months; the test strip should be used within two minutes after removal. • The test strip in single-headed packaging should be used immediately after the tear of the aluminum foil bag. • Do not use after the expiration date printed on the test strip package. The expired test strip will result in incorrect test results. • Please store the test strip according to the storage requirements, and improper storage of the test strip will lead to incorrect test results. • See the product label or outer packaging box for the production date and expiration date. This product should be used in conjunction with the IClearVet I type blood glucose and ketone tester produced by our company. Fresh capillary whole blood or venous whole blood containing anticoagulant (EDTA-2 Na or sodium heparin) from cows. Before using this product for testing, please read the test method corresponding to this ketone test strip carefully. Make sure you have prepared the test strip, tester, blood sampling needle, blood collector and other test supplies before testing. • Insert the code card: Remove the code card from the package and insert it into the code card slot at the bottom of the tester. • Blood sample collection: Before blood sampling, clean the animals blood sampling site with alcohol and dry it with clean gauze or let it dry naturally. Then use a blood sampling needle or blood sampler to collect fresh capillary whole blood or venous whole blood. • Insert the test strip: Insert the test strip and the tester will automatically turn on. When the symbol for dripping blood flashes on the tester screen, add blood to the sample port at the top of the test strip until it is full. The test structure will appear on the screen in 5 seconds. • Exit test strip: slide the exit button on the back of the tester, and the test strip will automatically exit. Please properly dispose of used test strips and blood collection needles, blood collectors, etc. Calf ketosis:

 Open the catalog to page 1
UG-1520830225180-Instruction Manual-ITGEN-Blood Ketone Test Strip--2

Blood Ketone Test Strip essential informatio^ Name of production enterprise: Hangzhou Antigenne Technology Co., LTD [Interpretation Of Test Results] • Blood ketone test results in the tester are expressed in mmol/L concentration units. • The test range of this product is 0mmol/L-8.0 mmol/L. "HI" signal indicates that the measurement result exceeds the measurement range. • The temperature range required for this product test is 5°C ~ 45°C. Exceeding the range may cause large deviation of the test results. • The humidity range required for this product test is 10%~90%. Exceeding the range may lead...

 Open the catalog to page 2

All Hangzhou Antigenne Technology Co. Ltd catalogs and technical brochures

  1. BVDV Ag

    1  Page

  2. BVDV Ag

    1  Page

  3. BRU Ab

    1  Page

  4. FPV GIA Ag

    1  Page

  5. CDV CPV Ag

    1  Page

  6. CDV CPIV Ag

    1  Page

  7. CDV CAV Ag

    1  Page

  8. FPV FCoV Ag

    1  Page

  9. ICH Ab

    1  Page

  10. HP Ag

    1  Page

  11. GIA Ag

    1  Page

  12. FPL

    1  Page

  13. FHV Ab

    1  Page

  14. FCV Ab

    1  Page

  15. FCoV Ab

    1  Page

  16. F.IgE

    1  Page

  17. F-BT A+B

    1  Page

  18. CRV Ag

    1  Page

  19. CAV Ag

    1  Page

  20. C.IgE

    1  Page

  21. C.FOB

    1  Page

  22. BC Ab

    1  Page

  23. FIPV Ag

    1  Page

  24. FeLV Ag

    1  Page

  25. FCoV Ag

    1  Page

  26. F.GIA Ag

    1  Page

  27. RAB Ag

    1  Page

  28. CPV Ab

    1  Page

  29. CIV Ag

    1  Page

  30. CAV-II Ag

    1  Page

  31. CAV-I Ag

    1  Page

  32. SE Ag

    1  Page

  33. BRU Ab

    1  Page

  34. FPV/FCoV Ag

    1  Page

  35. ITGen catalog

    28  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.