Catalog excerpts

Microbial Enumeration Monitor HTY Microbial Enumeration Monitor (disposable S60 type, referred to as S60) , is a specialized consumable that can be used in concert with a variety types of microbial enumeration tester or filter support for microbial limit testing in areas of pharmaceutical, purified water samples. Based on principles of membrane filtration method, this monitor separates microbes form the solution,and trapped the microbes on the filter membrane. Pour the culture medium on the back (non-bacterial surface) of the membrane.Put it under a specific environment and restore the growth of microbes on the filter.Then count and identify them when they formed some visible Membrane Material: Mixed cellulose ester Membrane pore size: 0.45 \i m F47 Microbial Enumeration Funnel can be used in concert with0 47mm micro-filtration membrane and the corresponding filter supporter or microbial enumeration tester, to form a microbial enumeration test system. This system can be widely applied to microbial enumeration testing for pharmaceutical, purified water,etc. Based on principles of membrane filtration method, this system separates microbes form the solution,and trapped the microbes on the filter membrane. Stick the membrane on the agar culture-medium.Put it under a specific environment and restore the growth of microbes on the filter.Then count and identify them when they formed some visible colony. Microbial Enumeration Funnel F47 VHPS Generator It is a suitable indicator for vapor hydrogen peroxide sterilization. The color of indicator card will change during sterilization. It will turn from green to light green or yellow I Related to the humidity and temperature). Cover the lid tightly each time after taking out the 2. Keep it in the dark and cool place. SGM Bacillus stearothermophilus (ATCC7953) is used to monitor the vaporized hydrogen peroxide sterilization (isolation). Tyvek ® mylar envelope contains stainless steel strip biological indicators. It is easy to operate. Transfer the sample to the microbiology laboratory after being sterilized, culture it for 7 days on the soybean casein digest medium. The carrier material does not absorb the hydrogen peroxide vapor or react with it; 3. Storage conditions: room temperature; 4. Quality Assurance: Indicator bacteria strains from a recognized depositary institution, both the number of spores and D values have been verified.
Open the catalog to page 1All Hangzhou Tailin Bioengineering Equipments catalogs and technical brochures
-
Tailin Vacuum Pump - HTY 30A
1 Pages
-
Tailin Homogenizer HTY-761
1 Pages
-
Tailin Shaker HTY-K
1 Pages
-
Tailin Sterility Test Pump
1 Pages