Product catalog summary
Overview of Titration Systems
Titration is a quantitative analytical method used to determine the concentration of an analyte by its complete reaction with a reagent. The process involves adding a titrant to a solution containing the analyte until the reaction reaches the equivalence point, which can be detected by a chemical indicator or a measurable physical change such as pH or conductivity.
Automatic Titration
Automatic titration systems, like the HI902C, automate the delivery of the titrant, endpoint detection, and calculation of analyte concentration. These systems are preferred for their accuracy and repeatability, using electrochemical measurements rather than subjective indicators.
HI902C Automatic Titration System
The HI902C system supports various titration types, including acid-base, redox, and complexometric titrations. It features linear and dynamic dosing, USB and RS232 ports for data transfer, multi-language support, a Clip-Lock™ exchangeable burette system, real-time titration curve display, and GLP compliance with comprehensive data storage.
Specifications
The HI902C offers a wide range of measurement capabilities, including pH, mV, and ISE measurements, with high accuracy and resolution. It supports up to 100 titration methods and features a customizable interface for data management and method sequencing.
HI921 Autosampler
The HI921 Autosampler automates the handling of up to 18 samples, enhancing the efficiency of the titration process. Key features include flexible sample tray configurations, automatic reagent addition and waste removal, a built-in magnetic stirrer, and a barcode reader interface for sample tracking. It integrates seamlessly with the HI902C.
Conclusion
Hanna Instruments' titration systems, including the HI902C and HI921 Autosampler, provide robust solutions for precise and efficient analytical chemistry applications. Their advanced features and automation capabilities make them suitable for a wide range of laboratory environments.
HI903 Karl Fischer Volumetric Titrator
The HI903 is designed for high-accuracy moisture determination, featuring a precision titrant delivery system and a sealed solvent system to minimize humidity exposure. It supports up to 100 titration methods and includes a titrant database for standardization.
HI904 Karl Fischer Coulometric Titrator
The HI904 offers high accuracy for low moisture content samples, using a dynamic dosing system with a sealed cell design. It includes a molecular sieve desiccant to prevent humidity ingress and supports direct connection to laboratory balances.
HI84530 Total Titratable Acidity Titrator and pH Meter
This device is a mini automatic titrator with a pH meter for rapid analysis of total titratable acidity in water. It features a piston-driven pump for dynamic dosing and a user-friendly interface.
General Features
Both devices support data transfer via USB and offer real-time monitoring and reporting capabilities. They are designed with intuitive interfaces, contextual help screens, and customizable options to meet user requirements.
Applications
The HI84529 is tailored for the dairy industry, measuring titratable acidity to assess product quality. The HI84532 is designed for fruit juice analysis, determining titratable acidity to evaluate fruit maturity and taste.
Conclusion
Hanna Instruments' mini titrators offer a comprehensive solution for titration needs in various industries, providing accurate, efficient, and user-friendly tools for quality analysis.
See more

Catalog excerpts

Hanna Titration Catalog-1

Titration Catalog Systems and Autosampler

 Open the catalog to page 1
Hanna Titration Catalog-2

Hanna Instruments® Titration Systems Titration is used in analytical chemistry to determine the amount or concentration of a substance, known as the analyte. Titration is a quantitative measurement of an analyte in solution by its complete reaction with a reagent. In a titration, one reagent (the titrant) is slowly added to a solution containing the species being measured (the analyte). As it is added, a chemical reaction occurs between the titrant and analyte. The point at which the reaction is complete and an equivalent quantity of titrant and analyte are present (a stoichiometric equivalent)...

 Open the catalog to page 2
Hanna Titration Catalog-3

The required equipment for automatic titration include an automatic titrator equipped with a burette, a standardized titrant, a volumetric pipette (to measure the sample volume) or analytical balance (to measure or weigh a sample), a beaker, a sensor, and a stirring mechanism. The automatic titrator must have an accurate liquid-dispensing system. In high accuracy systems, this is typically a motor-driven piston burette, a valve system to switch between titrant inlet and outlet, and a titration tip to dispense the titrant into the sample solution. These three main subsystems must be as accurate...

 Open the catalog to page 3
Hanna Titration Catalog-4

HI902C Automatic Titration System Automatic Titration System • Linear and dynamic dosing • USB port allows for the transfer of methods and reports to a PC or another titrator via USB flash drive • One or two sensor input models • RS232 port for connection to an analytical laboratory balance • VGA port for external monitor • Multi-language support Four working modes: • Potentiometric titrator · Choice of endpoint detection: equivalence point (1st or 2nd derivative) or fixed pH/mV value · Clip-Lock™ exchangeable burette system enables users to exchange burettes in a matter of seconds · Linked titration...

 Open the catalog to page 4
Hanna Titration Catalog-5

HI902C Automatic Titration System • Support for 2 electrodes, 2 burette dosing pumps and 2 stirrers • Clip-Lock™ Exchangeable Burette System · With Clip-Lock™, it only takes a few seconds to exchange the reagent burettes to perform a different titration. No need to purge, clean and refill • Method sequencing · Linked titration methods allow two methods to run in sequence • Easy upgrades · Field upgradable software via USB · Convenient for saving data Powerful Customization, Accurate Analysis The HI902C is an automatic titrator that complements our wide range of using a USB flash drive. Software...

 Open the catalog to page 5
Hanna Titration Catalog-6

HI902C Automatic Titration System Versatile Data Management • Data can be transferred to a PC using Hanna HI900PC software • HI902C titration system can be easily incorporated into any existing GLP • The USB port allows for the easy transfer of methods, reports and software upgrades via USB flash drive data management program: as sample identification, company and operator name, date, time, • Users can print reports of analyses directly from the titrator using a standard parallel printer electrode ID codes and calibration information • An external monitor and keyboard can be attached for added...

 Open the catalog to page 6
Hanna Titration Catalog-7

HI902C Automatic Titration System ±0.1°C; ±0.2°F; ±0.1K, excluding probe error Burette Sizes Burette Resolution Display Resolution Dosing Accuracy ±0.1% of full burette volume 5.7” (320 x 240 pixel) backlit color LCD English, Portuguese, Spanish load up to 100 methods (standard and user-defined) Burette Auto-Detection burette size is automatically recognized when inserted into the unit Programmable Stirrer overhead propeller type, 100-2500 RPM, resolution 100 rpm Flow Rate user-selectable from 0.1 mL/min to 2 x burette volume/min Temperature Compensation Endpoint Determination equivalence point...

 Open the catalog to page 7
Hanna Titration Catalog-8

control panel • Flexible, accurate detection of the titration endpoint with HI902C potentiometric titrator • Automation of up to 18 samples per tray · 16 sample tray holds 150 mL beakers · 18 sample tray holds 100 mL beakers • Absolute encoder in sample tray · The Autosampler always knows the tray position without the need to "home" or calibrate. • Electrode rinse feature · Up to 3 beakers per tray can be designated for electrode dip/spray rinses • Automatic addition of reagents or deionized water to the sample beaker by peristaltic pump • Optical IR beam detects presence or absence of beakers...

 Open the catalog to page 8
Hanna Titration Catalog-9

Automate up to 18 samples The HI921 Autosampler is an automated titration sample handling system designed for use with the HI902C Potentiometric Titration System. This high quality system makes the titration of multiple samples quick and easy. The HI921 can utilize up to three peristaltic pumps for automatic reagent addition, sample leveling and waste aspiration and one membrane pump for spray rinsing. An included control panel allows for manual operation of the motors and pumps. The HI921 also features a built-in magnetic stirrer, electrode rinse feature, USB interface with compatible barcode...

 Open the catalog to page 9
Hanna Titration Catalog-10

Peristaltic and Membrane Pumps • Up to three peristaltic pumps can be added at anytime • User replaceable pump systems • Peristaltic pumps · Uses high performance plastic that is engineered to be chemically resistant and have long service life. · Reagent addition, sample leveling, waste removal · Greater than 200 mL/min flow • Membrane pumps · Simple plug connection for tubing · Greater than 400 mL/min flow The Autosampler comes with multiple configurations for pumps, including up to three peristaltic pumps and a single membrane pump. The pump system has a simple install process and can be connected...

 Open the catalog to page 10
Hanna Titration Catalog-11

1 temperature sensor Electrode Holder Slots built-in RFID, transmits the tray type and serial number to Autosampler 5 multi - purpose slots (titrant/reagent tubes) ASTM short-form glass beakers 1 overhead stirrer Temperature Sensor HI920-060 (150 mL), fits HI920-11660 tray - 16 plastic beakers HI920-053 (100 mL), fits HI920-11853 tray - 18 plastic beakers built-in magnetic stirrer buttons for manual operation of tray and titration head Stirrers overhead propeller stirrer (optional) Control Panel manual operation of peristaltic or membrane pumps 2-line backlit display with status information Peristaltic...