HI84502
6Pages

{{requestButtons}}

Catalog excerpts

HI84502 - 1

Titratable Total Acidity Mini Titrator lllllll HkNNK

Open the catalog to page 1
HI84502 - 2

HI 84502 Mini Titrator for Wine Applications • Piston Driven Pump with Dynamic Dosing This piston driven dosing pump incorporates dynamic dosing to provide highly accurate, repeatable results. • CAL-CHECK® CAL-CHECK® alerts users to potential problems during calibration such as contaminated buffers or dirty/broken electrodes. • pH/mV Meter In addition to automatic titration, the HI 84502 can also be used as a pH/mV meter. • Log-on-Demand Log data up to 400 samples (200 for titration; 200 for pH/mV). • Graphic Mode/Exportable Data Displays in-depth data on titration, which can then be stored...

Open the catalog to page 2
HI84502 - 3

Easy to Use, Fast and Affordable All-in-one Solution The HI 84502 is an easy to use, fast and affordable automatic mini titrator designed for testing total acidity levels in wine. It includes a pre-programmed analysis method and uses a powerful algorithm in order to determine when the titration reaction has reached completion. The results are displayed in g/L as tartaric acid. This new generation of mini automatic titrator improves upon the titrant delivery system and measuring ranges for increased accuracy compared to previous models. The HI 84502 incorporates a precision piston driven...

Open the catalog to page 3
HI84502 - 4

Piston Driven Pump with Dynamic Dosing The HI 84502 incorporates dynamic dosing to provide precison titrant delivery. Dynamic dosing adjusts the amount of titrant dosed as the end point is approached for increased accuracy in end point detection. More About Dynamic Dosing Application Specific pH Electrode With the integration of our piston burette, our The HI 84502 is supplied with the HI 1048B pH electrode featuring CPS™ technology. This technology is used to prevent clogging of the reference junction. titrator can adjust the volume and frequency of titrant dosed based on relative mV...

Open the catalog to page 4
HI84502 - 5

Meter setup Calib. Timeout Disable Prepare the sample Add stir electrode holder. Insert Setup Screens The LCD features an easy to use setup screen that allows the user to change measuring range, time, date, language and more. Tutorial and HELP Screens Accessing the tutorial menu provides helpfu nformation during calibration and titration. CAL-CHECK is a Hanna exclusive process for checking the condition of electrodes which helps keep measurements accurate. last Electrode Calibration The GLPfeature records electrode and pump calibration data to help keep measurements Wrong Buffer Procedure...

Open the catalog to page 5
HI84502 - 6

HI 84502 - Titratable Total Acidity low range: 0.1 to 5.0 g/L of tartaric acid high range: 4.0 to 25.0 g/L of tartaric acid 3% of reading or ±0.1 g/L , whichever is greater acid-base titration Pump speed Stirring Speed Logging Data HI 84502-55 Calibration standard solution (120 mL) pH Calibration Solutions Buffer solution pH 4.01 (230 mL) Electrode Fill and Storage Solutions pH Meter Electrode fill solution (4 x 30 mL) Electrode storage solution (500 mL) Electrode Cleaning Solution Cleaning solution for wine deposits (500 mL) Cleaning solution for wine stains (500 mL) Temperature...

Open the catalog to page 6

All HANNA Instruments catalogs and technical brochures

  1. HI98129

    2 Pages

  2. HI4114

    9 Pages

  3. HI99191

    4 Pages

  4. HI99151

    4 Pages

  5. General Catalog

    772 Pages

  6. HI84500

    6 Pages