Overview: This document provides detailed technical specifications and guidelines for using Amber® Press, a material designed for all-ceramic dental restorations. It highlights the material's compatibility, strength, and aesthetic benefits.
Specifications: Amber® Press offers three levels of translucency (High Translucency, Medium Opacity, Low Translucency) and over 43 shades. It is available in different sizes and is compatible with various veneering materials. The material boasts a biaxial flexural strength of 460 MPa, making it stronger than conventional lithium disilicate press materials.
Procedures: The document outlines pressing schedules for different furnaces, including Austromat Press-i-dent, EP600, EP3000, and EP5000. Key parameters include start temperature, heating rate, final temperature, holding time, and press duration. Adjustments to temperature and holding time are recommended based on the presence of bubbles or incomplete formation.
Recommendations: Users are advised to verify the compatibility of Amber® Press with their press furnace and adjust parameters as needed. The document emphasizes the simplicity and safety of the process, noting that no acid is required for clean-up after pressing.
Applications: Amber® Press is suitable for inlays, onlays, veneers, anterior and posterior single crowns, and 3-unit bridges up to the second premolar. It is compatible with various veneering materials, including IPS e.max ceram, Initial LiSi, and others.
Notes: The document includes a disclaimer that the provided schedules are guidelines and may vary based on the actual furnace used. Users are responsible for testing product compatibility for any usage not specified in the instructions.
Contact Information: HASS Corporation provides contact details for customer support and further inquiries.
See more

Catalog excerpts

Amber Press-1

All Ceramic Materials for All-Ceramic Restorations Readiness for Diversity Pressing Schedules Pressing Schedules Pressing Schedules Horizon (Shenpaz)1 Translucency Investment Start Ring Temperature Heating Rate Holding Time Investment Start Ring Temperature Heating Rate Final Temperature Holding Time Press Duration Press Level Investment Stand-by Temperature Holding Ring Temperature Increase Temperature Stop Speed Holding Time Stop Speed Holding Time Lithium Disilicate-Based Press Ingots Investment Stand-by Temperature Holding Ring Temperature Increase Temperature Lithium Disilicate-Based Blocks with Zirconia Core for Implant Prostheses NOTE: The above schedules are referential guideline only Austromat Press-i-dent (Dekema)2 Translucency New Frontier of Lithium Disilicate-Based CAD/CAM Blocks & Disks Investment Stand-by Temperature Holding Ring Temperature Increase Temperature Holding Time Stop Speed There may be a difference between the displayed temperature and the real temperature of each furnace. When you use the Amber ingots, please verify the above standard schedule is suitable for your press furnace. If it is not, please try to find the optimum temperature through the following process. Lithium Disilicate-Based Press on Zirconia 1) If there are some traces of tiny bubble on the surface of the restoration ⇒ Please reduce the maximum temperature by 5~10℃ or holding time and try pressing again. 2) If the marginal area of the restoration is not formed completely ⇒ Please increase the maximum temperature by 5~10℃ or holding time and try pressing again. 1. Horizon is a registered trademark of Shenpaz Dental Ltd. 2. Austromat Press-i-dent is a registered trademark of DEKEMA Dental-Keramiköfen GmbH. 3. EP600, EP3000, EP5000 are registered trademarks of Ivoclar Vivadent. HASS Corporation 77-14, Gwahakdanji-ro, Gangneung-si, Gangwon-do, KOREA 25452 Tel: +82-70-7712-1300 / Fax: +82-33-644-1231 Customer Support : +82-2-2083-1367 E-mail : [email protected] Website : www.hassbio.com Printed in KOREA © HASS Corporation. All rights reserved. This material is designed for usage in dentistry. Follow instructions HASS is not liable for any loss caused by failure to comply with regulation or scope of indication. Users are responsible for testing products to verify the compatibility for any usage which are not written in the instructions. The explanations and data contained within do not carry any guarantees and/or obligations. All enclosed recommendations and restrictions apply when used with products from other manufacturers. AP_BR_IM_EN_200310

 Open the catalog to page 1
Amber Press-2

Outstanding Versatility Compatible with Various Veneering Materials Superior Strength Amber® Press’s flexural strength is higher than conventional Lithium Disilicate press materials. Amber Press presents the biaxial flexural strength of 460 MPa. Source : Internal Data Product Line-up Amber® Press ingots are compatible with various veneering materials for lithium disilicate. Dimensions (mm) Staining / Cut-back - IPS e.max ceram (Ivoclar Vivadent) * 200 - VINTAGE LD Porcelain (Shofu) * Biaxial Flexural Strength (MPa) - InSync (Jensen) * - Initial Zr-FS (GC) ** - Creation ZI-F (Creation Willi Geller)...