

Catalog excerpts

Dimension Weight Driven mode Gas supply Input pressure O2 flush Power supply Batter backup Agent type Patient type Tidal volume Ventilation mode Value Monitoring Graphic Monitoring 810x810x1360 mm (WxDxH) 96 kg Pneumatically driven, electronically controlled O2, N2O, Air 280-650 kpa 35-75 L/min 110/230VAC, 60/50HZ 60 minutes Halothane, Enflurane, Isoflurane, Sevoflurane, Desflurane Adult and Pediatric 20-1500 ml Manual, VCV, PCV, SIMV+/PSV Tidal volume, Minute Volume, Respiratory rate, l:E ratio Pmax, Pmean, Pplat FiO?%, EtCO;% (optional) V-T, P-T.F-T curves. P-V, P-F, V-F loops Anesthetic depth and trend (optional) Heal Force Leads You to Healthier Life Anaeston Series Anaeston 3000 Anesthesia Machine Alarm (Audible and visual alarm indication with diagnostic messages for trouble-shooting) Alarm silence 120 seconds High/low Vt, High/low MV, High/low Paw, High/low FiO?, High/low flow Alarm content High/low cerebral state index (for anesthetic depth) High/low EtCO?%, lnC02% and temperature (optional) Apnea alarm, Airway Malfunction, Power failure, Low battery etc. Optional extension \ TrackAO— A digital platform integrated the ‘Recording’ , ‘Monitoring’and‘Management' of all key anesthesia clinic information J Heal Force Bio-Meditech Holdings Group, Nison instrument (Shanghai) Limited 16th Floor, Building B, SOHO Zhongshan Plaza, 1065 West Zhongshan Road, Changning District, Shanghai 200051,China Tel +86 21 62728646, Email export@healforce.com, Fax +86 21 62728646 Shanghai Lishen Scientific Equipment Co., Ltd. No.6788, Songze Avenue, Qingpu, Shanghai 201706, P.R. China Information Is subject to change and/or updating without notice ©2016 Heal Force. CL-NISON-EN-MEDICALEQUIPMENT-MZJ-20160505
Open the catalog to page 1
Simply All Your Need Elaborate Airway Design Classic closed-loop design with latex-free components. Easy detachable and replaceable bellow compartment agree with sterilization. Double layer C02 absorber with its capacious volume optimized for long-time operation. Minimum 20ml Tidal Volume supports Low-flow/Pediatric Anesthesia, with 3-level alarming system serving as the guidance. 3 Gas-source, 3 Cylinder Backups All-round 02/N20/AIR Gas-Source Inlets. 2 auxiliary cylinder (Size E) gas interfaces (up to 3) backup source pre-installed. Multiple cylinder installation customization provided,...
Open the catalog to page 2All Heal Force catalogs and technical brochures
-
Clean bench/AlphaClean 1300
12 Pages
-
Cytotoxic cabinet
20 Pages
-
CO2 Incubator
6 Pages
-
Heal Force Real Time PCR
11 Pages
-
Medical Supply
8 Pages
-
Anaeston Series
8 Pages
-
Healthcare device
12 Pages
-
Head Massager
2 Pages
-
Body Massager
2 Pages
Archived catalogs
-
Prince 120 Body Fat Analyzer
2 Pages
-
EB03D
2 Pages
-
EB05
6 Pages
-
Deluxe-70
2 Pages
-
Toplite-FII
8 Pages
-
TopLED
4 Pages
-
Anaeston 5000/Anaeston 3000
8 Pages
-
A8 Endoscopy Ceiling Pendant
8 Pages
-
A8 Surgery Ceiling Pendant
8 Pages
-
HFease100
4 Pages
-
HFease400
4 Pages
-
EST-1
4 Pages