EB05 High Frequency Surgical Unit - 2 Pages

Add to MyMedicalExpo favorites
EB05 High Frequency Surgical Unit

Catalog excerpts

EB05-AR Functions on Control Panel Overpressure system (active in low gas mode only) System purge control Gas flow control Gas tank indicators and control Receptacles for gas line, RF input, peritoneal pressure tubing and handset Alarm System In case of the following errors or problems, the audio and visual alarm is active: Handset tubing obstruction Overpressure of gas flow, especially in laparoscopic operations Peritoneal pressure tubing obstruction Automatic Gas Tank Switch The system is able to switch to backup gas tank automatically in case the pressure of working gas tank drops below threshold, without interruption of gas flow in handset. EB05-AR The EB05-AR argon coagulation unit, an optional accessory for Heal Force EB05 high frequency surgical unit, is designed to provide controllable argon flow over the active electrode. With the help of EB05-AR, the surgeons can expect: Non-contact procedure, no sticking of the instrument tip to the tissue Effective surface coagulation and hemostasis Controllable penetration depth Extremely low risk of perforation Low level of carbonization and smoke, very little pollution and odor Few complications Overpressure System The low gas mode (0.5~4 LPM) of EB05-AR is beneficial for laparoscopic operation to avoid excessive peritoneal pressure, in addition, a peritoneal pressure tube is also available for real time peritoneal pressure inspection to cut off gas in case of overpressure. Gas Flow Options Two gas flow modes are optional for the argon-enhanced electrosugeries, besides the standard gas flow mode (range 0.5~12LPM), which is universally use in routine surgical applications, the low gas flow mode (0.5~4 LPM) is also available for laparoscopic operations to avoid overpressure. EB05 EB05 High Frequency Surgical Unit EB05-AR Argon Coagulation Unit

 Open the catalog to page 1

EB05 High Frequency Surgical Unit EB05 Sometimes a surgery needs 2 operators to work together. EB05 provides 2 receptacles to allow 2 hand control pencils (or 1 hand control and 1 foot control pencil) to work on monopolar coagulation simultaneously. With consistent quality of vaporization, safe hemostasis and uniform coagulation depth, EB05 is easy to implement the TUVP operation. Compatible with Heal Force EB05-AR argon coagulation unit, EB05 supports argon coagulation function.

 Open the catalog to page 2

All Heal Force catalogs and technical brochures

  1. EB05

    6 Pages

  2. Neofuge 15-15R

    4 Pages

  3. CO 2 incubator

    6 Pages

  4. HFsafe CY Series

    20 Pages

  5. Anaeston Series

    8 Pages

  6. NW

    24 Pages

  7. PW

    24 Pages

  8. 13R

    6 Pages

  9. Head Massager

    2 Pages

  10. Neofuge 18R

    4 Pages

  11. Neofuge 23R

    6 Pages

  12. Body Massager

    2 Pages

  13. Prince 180A/B

    2 Pages

  14. Prince-100A/B

    2 Pages

  15. EB03D

    2 Pages

  16. EB05

    6 Pages

  17. Genius-15

    2 Pages

  18. Advance-150

    2 Pages

  19. Classic-120

    2 Pages

  20. Deluxe-70

    2 Pages

  21. Toplite-FII

    8 Pages

  22. TopLED

    4 Pages

Archived catalogs

  1. HFease100

    4 Pages

  2. HFease400

    4 Pages

  3. EST-1

    4 Pages