Model 349KLX
1 / 23Pages

Catalog excerpts

Model 349KLX - 1

Model 349KLX Remote Display Digital Scale User Instructions

Open the catalog to page 1
Model 349KLX - 2

Model 349KLX Thank you for your purchase of this Health o meter® Professional product. Please read this manual carefully, and keep it for easy reference or training. Note: This scale has been factory calibrated, and does not require calibration prior to use. Please register your scale for warranty coverage at: http://www.homscales.com/customer/registration.aspx For User Instructions updates and revisions please go to: http://www.homscales.com

Open the catalog to page 2
Model 349KLX - 3

To prevent injury and damage to your scale, please follow these instructions very carefully. Assemble and operate the scale per the enclosed user instructions. For accurate weighing, this scale must be placed on a flat, stable surface. For accurate weighing, verify before each use the proper operation according to the procedure described in this manual. Operating this scale at voltages and frequencies other than specified can damage the equipment and will void the warranty. Do not transport the scale with any weight on the platform. Do not exceed recommended weight limit of 400 lb / 180 kg...

Open the catalog to page 3
Model 349KLX - 4

SPECIFICATIONS FOR THIS SCALE General The Model 349KLX remote display digital scale uses highly sophisticated microprocessor technology. Each precision scale is designed to provide accurate, reliable and repeatable weight measurements. In addition, each scale is designed to provide the user with features that make the weighing process simple, fast, and convenient. This scale is set up to use weighing technology in order to determine the actual weight of a moving patient. Weight can be displayed in pounds (lb) or in kilograms (kg). For privacy and convenience in use, the scale features a...

Open the catalog to page 4
Model 349KLX - 5

CERTIFICATIONS / CONNECTIVITY / DISPOSAL Certification Descriptions Pelstar, LLC has been officially certified as the manufacturer of Health o meter® Professional medical devices. The Pelstar, LLC quality assurance system covers the development, production, sales and service of medical scales and measuring systems. 349KLX Scale Connectivity Information To enable reliable transmission of weight, this scale is designed to connect to a computer, monitor, or other electronic device via a built-in RS-232 serial port. This connectivity helps minimize a source of potential medical errors caused by...

Open the catalog to page 5
Model 349KLX - 6

349KLX ASSEMBLY INSTRUCTIONS Before Assembly Each 349KLX remote display digital scale is shipped disassembled in one carton. Carefully inspect the carton for shipping damage before unpacking. If damage is found, contact your shipper or a Health o meter® Professional representative immediately at 1-800-815-6615. Claims must be filed with the shipper as soon as possible after receipt of the package. The following information details what you will find inside the main carton as you unpack the parts for assembly. To prevent scratching any components, carefully remove each assembly from the...

Open the catalog to page 6
Model 349KLX - 7

349KLX ASSEMBLY INSTRUCTIONS (CONTINUED) Assembling the 349KLX Scale (Refer to Figures 1- 4) 1. Carefully remove the scale platform and display assembly from the carton, and place the scale platform and display assembly on a flat, level, and dry surface (see Figure 3). 2. Connect the cable to the display assembly RJ jack (see Figures 2 & 3). 3. Remove the display bracket from the carton (see Figure 1). 4. Remove the two small screws from plate B (see Figure 1). 5. While holding plate A, slide the tab of plate B up and under the center tab on the back of plate A (see Figure 1). 6. Align...

Open the catalog to page 7
Model 349KLX - 8

349KLX ASSEMBLY INSTRUCTIONS (CONTINUED) Display Bracket Mounting studs Screws Center tab Plate A Screw holes Adapter jack Display assembly

Open the catalog to page 8
Model 349KLX - 9

349KLX ASSEMBLY INSTRUCTIONS (CONTINUED) Display assembly Scale platform RJ jack

Open the catalog to page 9
Model 349KLX - 10

DISPLAY ASSEMBLY WALL MOUNT INSTRUCTIONS Display Assembly Wall Mounting Instructions (Refer to Figure 4) Caution: When wall mounting the display assembly, ensure that the mounting location is free of electrical lines, gas pipes, and other safety hazards. Ensure that wall is of construction that can support the display assembly. Note: Remote head can be mounted to a wall up to 6 feet (1.83 m) from the base or it can be mounted on the display bracket (included) for placement on a table up to 6 feet (1.83 m) from the base. 1. Position the display assembly on the wall, and carefully trace...

Open the catalog to page 10
Model 349KLX - 11

DISPLAY ASSEMBLY WALL MOUNT INSTRUCTIONS (CONT) Mounting hole Display assembly Mounting hole

Open the catalog to page 11
Model 349KLX - 12

SETUP / BATTERY / TRANSPORT Preparing the 349KLX Scale for Use Replacing / Inserting Battery 1. Unplug the AC adapter from the power source. 2. Remove the battery cover on the side of the display assembly by sliding the battery cover out (see Figure 5). 3. Replace or install the battery (Figure 6). Note: Health o meter® Professional recommends using an alkaline or lithium battery, rated for 130°F (54°C) operation. Do not use zinc-carbon battery. 4. Re-attach the battery cover to the display assembly. Warning: If the scale will not be used for some time, remove the battery to avoid a safety...

Open the catalog to page 12
Model 349KLX - 13

SETUP / BATTERY / TRANSPORT (CONTINUED) Display assembly Battery cover Figure 5 Cover snaps 9V battery terminals

Open the catalog to page 13
Model 349KLX - 14

SETUP / BATTERY / TRANSPORT (CONTINUED) Preparing a 349KL Scale for Transport This scale can be easily placed into carrying case (# 64771) for storage, or transport from one room to another. This scale does not include the carrying case item # 64771, and must be acquired separately (see Figure 7). To prepare the scale for transport, follow these steps: 1. Remove the display assembly and display bracket from its current position. 2. Unplug the AC adapter and cable from the display assembly, and remove the AC adapter from the outlet. 3. Carefully store the AC adapter, display bracket, and...

Open the catalog to page 14
Model 349KLX - 15

SETUP / BATTERY / TRANSPORT (CONTINUED) Scale platform Display assembly Display bracket

Open the catalog to page 15
Model 349KLX - 16

QUICK START / OPERATING INSTRUCTIONS Keypad Tares the scale prior to weighing (0.0). Toggles between pounds (lb) and kilograms (kg).

Open the catalog to page 16
Model 349KLX - 17

QUICK START / OPERATING INSTRUCTIONS (CONT) Auto-Off Function As an energy saving feature, the scale will automatically powers off after 2 minutes of inactivity. This function is enabled by default. Note: Ensure cable is attached to the display assembly RJ jack, and make sure there is no object on the scale platform. Disable Auto-Off 1. While the scale is powered off, press and hold the lb./kg button. 2. While holding the lb./kg button, press the ON button to power the scale on. 3. “349” will briefly appear on the display followed by “A-OF” and then “0.0” lb appears. 4. Release the lb./kg...

Open the catalog to page 17

All Health O meter Professional catalogs and technical brochures

  1. 894KLT

    2 Pages

  2. 3400KG

    2 Pages

  3. 2600KL

    2 Pages

  4. 3001KL-AMX

    2 Pages

  5. 2000KL

    2 Pages

  6. 142KL

    2 Pages

  7. 160KG

    2 Pages

  8. 160LB

    2 Pages

  9. 160KL

    2 Pages

  10. 400KL

    2 Pages

  11. BCS-G6

    2 Pages

  12. 499KLHR

    2 Pages

  13. PORTROD

    1 Pages

  14. Model 2101KL

    21 Pages

  15. Model 600KL

    13 Pages

  16. Model 498KL

    23 Pages

  17. 597KL

    2 Pages

  18. 594KL

    2 Pages

  19. 499KL

    2 Pages

Archived catalogs

  1. 596KL

    2 Pages

  2. 222KL

    2 Pages