Model 600KL
13Pages

{{requestButtons}}

Catalog excerpts

Model 600KL - 1

600KL Physician Electronic Scale With Integral Digital Height Rod 600 lb x 0.2 lb 272 kg x 0.1 kg USER INSTRUCTIONS Patent Pending

Open the catalog to page 1
Model 600KL - 2

600KL PROFESSION AL DIGITAL PHYSICIANS SCALE WITH INTEGRAL DIGITAL HEIGHT ROD USER INSTRUCTIONS Thank you for your purchase of this Health o meter® Professional scale. Please read this manual carefully and keep it for easy reference or training.

Open the catalog to page 2
Model 600KL - 3

CAUTION AND WARNING To prevent injury and damage to y our scale, please follow these instructions very carefully: · · · · · · · Do not transport the scale while platform is loaded. Be sure the scale is tilted enough to assure it is rolling properly on its wheels when it is moved for cleaning or transported from one area to another. For accurate weighing the scale must be placed on a flat, stable surface. For accurate weighing, verify proper operation according to the procedure described in this manual before each use. Do not use in the presence of flammable materials. Operating at other...

Open the catalog to page 3
Model 600KL - 4

CONNECTIVITY / CERTIFICATIONS SCALE CONNECTIVITY INF ORMATION: This scale is designed to connect to other devices via a USB port, to allow acquisition of weight, height and BMI from the scale, to help close a source of potential medical errors caused by incorrectly copying and then recording a weight taken. This scale is EMR-EHR compatible. For more information regarding how to connect this scale to your computer, a monitor or other device please contact Customer Service. CERTIFICATION DESCRIPTIONS: This product meets the requirements of: 1. UL60601-1 First Edition: Safety for Medical...

Open the catalog to page 4
Model 600KL - 5

Screw in the 4 hex screws with a 5mm hex driver. 4. Plug load cell cable into the load cell plug in base of scale (see diagram 1a). The base of the scale has been designed to provide wire management for the load cell cable. Route the load cell cable as shown in diagram 1b. Diagram 1a Set the base/pillar assembly upright. Plug the cable labeled SCALE into SCALE jack in display module. Plug the cable labeled COM into the COM jack in the display module. Place the display module on top of the pillar and use the Phillips screw to fasten the module to the pillar

Open the catalog to page 5
Model 600KL - 6

SET UP Remove the protective film from the display window on the display head. Make certain that the scale base is on a stable, flat surface and that the sides of the base are clear of any obstacles. Utilizing the leveling bubble located at the top of the scale platform, level the scale by adjusting the leveling feet at each corner of the base. PREPARING THE SCALE FOR USE 1. Place the batteries in the battery holder (see Replacing Batteries information below). 2. For AC operation plug the adapter into the base of the scale and into the power source, or use the DC IN plug on the back of the...

Open the catalog to page 6
Model 600KL - 7

QUICK S TART OPERATING INSTRUCTIONS - CONTINUED Using the Keypad KEY Zeros the scale prior to weighing. Holds the value of the weighed object on the display until the button is pressed again to clear the value. Toggles between kilograms or pounds. Scrolling method for entering weight when in Calibration mode. Toggles the display between the weight reading, height reading and corresponding Body Mass Index (BMI) reading. Scrolling method for entering weight when in Calibration mode. Functions to unlock height and BMI display. Used to lock the height and BMI display and to send weight, height...

Open the catalog to page 7
Model 600KL - 8

CALIBRATION This scale is factory calibrated and does not require calibration prior to use. The calibration procedure may be performed using a known / certified weight in either pounds or kilograms. The default is in pounds, but calibration can be done in kilograms. The following instructions assume the scale is set to pounds. If you prefer to calibrate in kilograms, please call Customer Service at 800-815-6615. Note: Calibration weight must be no less than 60 lb (27kg) and no more than 300 lb (150 kg). DISPLAY SHOWS Turn the scale on. W hile START is displayed (for 3 seconds); Press ZERO -...

Open the catalog to page 8
Model 600KL - 9

TROUBLESHOOTING (CONTINUED) ERROR LIST ERROR NO. Mathematical mistake; division by zero. Cannot calculate calibration factor Will show when trying to calibrate with no calibration weight W eight loaded too low. Cannot calibrate While in calibration procedure add more weight in load mode Unstable weight. Cannot calibrate Check the load cells mechanical surroundings and see nothing touches them and the cables are well connected Calibration disabled Toggle the calibration switch to enable High saturation state (high A/D) The load cell is not connected correctly. Check the connection, cables,...

Open the catalog to page 9
Model 600KL - 11

SCALE PARTS FOR MAINTENANCE

Open the catalog to page 11
Model 600KL - 12

Description Outer Height Rod Bottom Cover Guide Block Large Guide Block COM Cable Sensor Branch PCB L Plate Sensor Branch PCB M2.5x6 Flat Head Screw M6 Screw Plate Pillar 6P6C Cable Adapter Box Cover Height Rod Control PCB Adapter Box Adapter Pillar Base Wheel 6 Block Circle Pillar Base Rubber Foot Platform Gradienter 14.7x8mm Platform Mat Rubber Bumper M3x5 Large Head Screw UC-O Fixation Block Scale Base Foot Battery Cover C-Battery (not included) M3x5 Round Head Screw Battery Box M6x22 Round Head Hexagon Screw Base PCB Assembly M3x8 Round Head Screw 250Lb Load Beam Hex Sealing Screw

Open the catalog to page 12
Model 600KL - 13

2-YEAR LIMITED WARRANTY What does the Warranty Cover? This Health o meter® Professional scale is warranted from date of purchase against defects of materials or in workmanship for a period of two (2) years. If product fails to function properly, return the product, freight prepaid and properly packed to Customer Service (see To Get Warranty Service , below, for instructions). If the authorized customer service provider determines that a defect of material or in workmanship exists, the customer s sole remedy will be repair or replacement of the scale at no charge. Replacement will be made...

Open the catalog to page 13

All Health O meter Professional catalogs and technical brochures

  1. 894KLT

    2 Pages

  2. 3400KG

    2 Pages

  3. 2600KL

    2 Pages

  4. 3001KL-AMX

    2 Pages

  5. 2000KL

    2 Pages

  6. 142KL

    2 Pages

  7. 160KG

    2 Pages

  8. 160LB

    2 Pages

  9. 160KL

    2 Pages

  10. 400KL

    2 Pages

  11. BCS-G6

    2 Pages

  12. 499KLHR

    2 Pages

  13. PORTROD

    1 Pages

  14. Model 2101KL

    21 Pages

  15. Model 349KLX

    23 Pages

  16. Model 498KL

    23 Pages

  17. 597KL

    2 Pages

  18. 594KL

    2 Pages

  19. 499KL

    2 Pages

Archived catalogs

  1. 596KL

    2 Pages

  2. 222KL

    2 Pages