Specifications Overview:
The HPL Single Function Recessed Linear Static White Luminaire is designed for healthcare settings, providing ambient lighting with bedside dimming via a low voltage digital controller. It is available in lengths from 24" to 96" and can be mounted in various ceiling types, including sheet rock with flange, trimless mud-in, or grid ceilings. The luminaire features a snap-in acrylic lens for uniform illumination and offers symmetric or asymmetric light distributions. It supports nLight® wired and wireless options and complies with IP64 Wet Location and NSF Splash Zone 2 standards.
Performance Data:
The luminaire offers lumen outputs from 500 to 1300 lumens per foot, with input wattage varying accordingly. It achieves high efficiency with lumens per watt ranging from 90 to 108, providing flexibility in lighting design.
Construction and Materials:
The housing is made of extruded aluminum with cast aluminum endcaps and a cold-rolled steel upper electronics channel. The lens is translucent opal acrylic with a silicone gasket. The reflector is painted steel with a gloss white powder coat, offering 95% reflectivity. The finish includes antimicrobial properties to inhibit bacterial growth.
Mounting Options:
Three installation options are available: Grid mount for lay-in or tegular grid ceilings, Flanged mount for post sheet rock install, and Flangeless/trim-less mud-in for sheet rock. Each option is tailored for specific ceiling types and installation requirements.
LED and Driver Specifications:
The luminaire supports multiple LED lumen packages with color temperatures from 2700K to 5000K, available in 90CRI or 95CRI. The LED life is rated for 86,000 hours at L70. The eldoLED® driver provides smooth dimming to dark <1% and is tested for EMI and RFI compliance.
Control and Networking:
Optional integrated nLight® controls allow digital communication with other nLight enabled devices. The luminaire can be controlled via remote nLight AIR wireless or standard Cat-5 cabling. A digital low voltage control option is available for bedside or wall switch control.
Environmental and Certification:
The luminaire is suitable for wet locations and operates in temperatures from -20°C to +25°C. It is CSA certified for U.S. and Canadian standards and meets MIL-STD 461G with the optional RIF feature. It is also Buy American compliant.
Warranty:
A 5-year limited warranty is provided, with terms available on the Acuity Brands website.
Overview: This document provides technical specifications and installation guidelines for the Healthcare Lighting Single Function Recessed Linear Static White Luminaire. It includes details on dimensions, mounting options, LED configurations, control options, and emergency features.
Specifications:
  • Dimensions: Available in lengths of 24, 36, 48, 72, and 96 inches with corresponding metric measurements. The width is consistently 3.875 inches with a tolerance of +/- 1/8 inch.
  • Mounting Options: Includes Grid (G), Flange (F), and Trimless Mud-In (GB) styles, each with specific overall length measurements.
  • LED Configurations: Lumen packages range from 500LMF to 1300LMF, with the number of boards and drivers varying by fixture length.
Installation and Features:
  • Mounting Brackets: Adjustable grid mounting brackets are included, with specific knockout (KO) locations for wiring.
  • Control Options: Supports various dimming controls including eldoLED ECOdrive and SOLOdrive with options for 0-10V, DALI, and nLight systems.
  • Emergency Features: Non-IC rated with options for integral battery backup and remote test switch.
Additional Components:
  • Pillow Switch: Allows ambient light control with multiple toggle settings for different light intensities.
  • nLight and nLight AIR: Details on wired and wireless network integration, including RJ45 jack and antenna locations.
Diagrams and Layouts: Includes schematic diagrams for LED configurations and installation layouts, emphasizing the positioning of fixtures relative to patient beds and headwalls.
Notes: Specifications are subject to change without notice, and the document includes references to Acuity Brands Lighting's patents and trademarks.
See more

Catalog excerpts

HPL Single Function Recessed Linear Static White Luminaire-1

Type: Project: Single Function Recessed Linear Static White Luminaire • Ambient light fixture w/ integral low voltage digital controller for sequential dimming bedside control • Single or paired fixture selection allowing maintenance access without working directly over bed • Recessed 4" x 24"/ 36"/ 48" / 72"/ 96" linear lengths • Versatile mounting trims for sheet rock w/ flange, sheet rock trimless mud-in, or grid ceiling types F Snap-in acrylic lens provided uniform illumination Symmetric or asymmetric light distributions available nLight® wired and wireless options2 IP64 Wet Location standard, NSF Splash Zone 2 standard, and MIL-STD 461G with added RIF filter Trimless Mud-In Trimless Mud-In PERFORMANCE DATA Lumen Output Lumen values are from photometric tests from an accredited laboratory. Data is considered to be representative of the configurations shown, within generally accepted industry tolerances. Performance data based upon 48LONG/ASDL/35K/90CRI/NX Ambient Nominal Nominal /FT Performance data based upon 48LONG/SYD/35K/90CRI/NX Delivered Lumens/FT Ambient Nominal Nominal /FT Delivered Lumens/FT Input Watts/FT Input Watts/FT Healthcare Lighting • (888) 834-5684 • www.healthcare-lighting.com © 2021 Acuity Brands Lighting, Inc. All Rights Reserved. “Healthcare Lighting” is a registered trademark of Acuity Brands Lighting. Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

 Open the catalog to page 1
HPL Single Function Recessed Linear Static White Luminaire-2

Type: Project: Single Function Recessed Linear Static White Luminaire A+ Capable options indicated by this color background. CATALOG NUMBER Example: HPL 1F 48LONG G MVOLT ASDL 1000LMF 30K 95CRI NX LVD NLIGHT MIN1 1C MBKAM Fixture Count 120 120 volt 277 277 volt 347* 347 volt MVOLT** 120-277 Volt *Not available w/ E10WLCP or BGTD **Not available w/ E10WLCP **Not available w/ combining 1000LMF & BGTD **Not available w/ combining 1300LMF & NLIGHT or NLTAIR2 **Not available w/ combining 1300LMF & BGTD Healthcare Patient Linear Single Fixture Dual Fixture Set Ambient LED Color Temperature Ambient...

 Open the catalog to page 2
HPL Single Function Recessed Linear Static White Luminaire-3

Type: Project: Single Function Recessed Linear Static White Luminaire SPECIFICATIONS Housing Extruded aluminum ceiling trim with cast aluminum endcaps and fabricated 18 gauge cold-rolled steel upper electronics channel housing. Lens Extruded 1/16" translucent opal acrylic snap-in lens profile sealed with closed cell silicone gasket along all four sides. Reflector Formed painted steel with gloss white powder coat; 95% reflectivity. Distribution Symmetric (SYD) with standard lens or 17.5° Asymmetric (ASD, ASDL, ASDR) distribution with standard lens and inner angled boards. Finish Painted in durable...

 Open the catalog to page 3
HPL Single Function Recessed Linear Static White Luminaire-4

Type: Project: Single Function Recessed Linear Static White Luminaire PHOTOMETRICS Lumen values are from photometric tests from an accredited laboratory. Data is considered to be representative of the configurations shown, within generally accepted industry tolerances. AMBIENT with Asymmetrical Distribution AMBIENT with Symmetrical Distribution Polar Candela Distribution Polar Candela Distribution Lumen Multiplier Table for CCT & CRI *Performance data based upon 35K/90CRI Ambient Nominal Lumens Per Foot This table can be used to approximate the lumen values at different kelvin temperatures. Data...

 Open the catalog to page 4
HPL Single Function Recessed Linear Static White Luminaire-5

Type: Project: Single Function Recessed Linear Static White Luminaire CEILING TRIM F F (Flanged Sheetrock) (Flanged Sheetrock) GB GB (Flangeless Sheetrock Mud-In) (Flangeless Sheetrock Mud-In) MOUNTING Rough-In Dimensions F and GB Ceiling Trims *For more mounting information, please reference the installation instructions. SIZE 24LONG 36LONG 48LONG 72LONG 96LONG NLIGHT AIR ANTENNA IF EQUIPPED NLTAIR2 MODELS ONLY ACCESS PLATE ELECTRONICS CHANNEL GROUNDING POINT 2X 1/2" KO OCCURS ONE END ONLY .875 22 ADJUSTABLE GRID MOUNTING BRACKET 1.17 MIN 30 GRID MOUNTING BRACKETS ACCESS PLATE INCLUDES 2X KO...

 Open the catalog to page 5
HPL Single Function Recessed Linear Static White Luminaire-6

Type: Project: Single Function Recessed Linear Static White Luminaire DIMENSIONS F NLIGHT AIR ANTENNA NLTAIR2 MODELS ONLY GROUNDING POINT 2X 1/2" KO OCCURS ONE END ONLY .875 22 INSTALLATION CLIPS RJ-45 JACK NLIGHT MODELS ONLY INSTALLATION CLIPS ACCESS PLATE INCLUDES 2X KO ELECTRONICS CHANNEL ACCESS PLATE HOUSING EXTRUSION LENS DIFFUSER LUMINOUS OPENING INSTALLATION CLIPS Trimless Mud-In RJ-45 JACK IF EQUIPPPED NLIGHT MODELS ONLY NLIGHT AIR ANTENNA IF EQUIPPED NLTAIR2 MODELS ONLY MOUNTING HOLES POSITION VARIES WITH MODEL LENGTH GROUNDING POINT 2X 1/2" TRADE SIZE KO .875 22 ACCESS PLATE ELECTRONICS...

 Open the catalog to page 6
HPL Single Function Recessed Linear Static White Luminaire-7

Type: Project: Single Function Recessed Linear Static White Luminaire LED SCHEMATIC Schematic simplification of lighting options within luminaire, viewed in cross section, facing headwall. ASDL NX INTELLIGENT LUMINAIRE TECHNOLOGY GUIDE Choose Nomenclature from these columns Minimum Dimming Level Dimming Range eldoLED ECOdrive LINEAR DIMMING, TO BE WIRED TO 0-10V CONTROL LINEAR DIMMING, TO BE WIRED TO DALI CONTROL eldoLED ECOdrive eldoLED ECOdrive eldoLED ECOdrive LINEAR DIMMING, RIO EZDL ACWH 90 G2 ANTENNA ON BACK OF LUMINAIRE eldoLED SOLOdrive LINEAR DIMMING, TO BE WIRED TO 0-10V CONTROL eldoLED...

 Open the catalog to page 7
HPL Single Function Recessed Linear Static White Luminaire-8

Type: Project: Single Function Recessed Linear Static White Luminaire WALL POD Reference spec sheet for nPODMA for complete ordering nomenclature. HPL 2F NLIGHT AMBIENT nPODMA DX (purchase separately) nPODMA DX (purchase separately) NON-IC THERMAL PROTECTOR 2.00 51 LUMEN OUTPUT CONTROL INPUT ZT, DALI, ECOD, NLIGHT, OR NLTAIR2 ZT, DALI, ECOD, NLIGHT, OR NLTAIR2 INSULATION DETECTOR ADDITIONAL DETECTOR Note: BLANK refers to the option not used. E10WLCP option always Non-IC 1.84 47 Healthcare Lighting • (888) 834-5684 • www.healthcare-lighting.com © 2021 Acuity Brands Lighting, Inc. All Rights Reserved....

 Open the catalog to page 8
HPL Single Function Recessed Linear Static White Luminaire-9

Type: Project: Single Function Recessed Linear Static White Luminaire NLIGHT & NLTAIR2 DETAILS NLIGHT (Wired) Enabled Network RJ45 Jack Location Typical for all mounting styles (Grid mount shown for reference.) .58 15 RJ45 JACK TO NLIGHT NETWORK NLTAIR2 (Wireless) Enabled Network Antenna Location Typical for all mounting styles (Grid mount shown for reference.) NLIGHT AIR ANTENNA EMERGENCY E10WLCP Specific voltage designation required on fixture when ordering. When fixtures are ordered as a 2F (Dual Fixture Set) and E10WLCP, each fixture will be supplied with an integral battery backup and remote...

 Open the catalog to page 9
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.