HPL Single Function Recessed Linear Static White Luminaire
1 / 9Pages

Catalog excerpts

HPL Single Function Recessed Linear Static White Luminaire - 1

Type: Project: Single Function Recessed Linear Static White Luminaire • Ambient light fixture w/ integral low voltage digital controller for sequential dimming bedside control • Single or paired fixture selection allowing maintenance access without working directly over bed • Recessed 4" x 24"/ 36"/ 48" / 72"/ 96" linear lengths • Versatile mounting trims for sheet rock w/ flange, sheet rock trimless mud-in, or grid ceiling types F Snap-in acrylic lens provided uniform illumination Symmetric or asymmetric light distributions available nLight® wired and wireless options2 IP64 Wet Location standard, NSF Splash Zone 2 standard, and MIL-STD 461G with added RIF filter Trimless Mud-In Trimless Mud-In PERFORMANCE DATA Lumen Output Lumen values are from photometric tests from an accredited laboratory. Data is considered to be representative of the configurations shown, within generally accepted industry tolerances. Performance data based upon 48LONG/ASDL/35K/90CRI/NX Ambient Nominal Nominal /FT Performance data based upon 48LONG/SYD/35K/90CRI/NX Delivered Lumens/FT Ambient Nominal Nominal /FT Delivered Lumens/FT Input Watts/FT Input Watts/FT Healthcare Lighting • (888) 834-5684 • www.healthcare-lighting.com © 2021 Acuity Brands Lighting, Inc. All Rights Reserved. “Healthcare Lighting” is a registered trademark of Acuity Brands Lighting. Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

Open the catalog to page 1
HPL Single Function Recessed Linear Static White Luminaire - 2

Type: Project: Single Function Recessed Linear Static White Luminaire A+ Capable options indicated by this color background. CATALOG NUMBER Example: HPL 1F 48LONG G MVOLT ASDL 1000LMF 30K 95CRI NX LVD NLIGHT MIN1 1C MBKAM Fixture Count 120 120 volt 277 277 volt 347* 347 volt MVOLT** 120-277 Volt *Not available w/ E10WLCP or BGTD **Not available w/ E10WLCP **Not available w/ combining 1000LMF & BGTD **Not available w/ combining 1300LMF & NLIGHT or NLTAIR2 **Not available w/ combining 1300LMF & BGTD Healthcare Patient Linear Single Fixture Dual Fixture Set Ambient LED Color Temperature...

Open the catalog to page 2
HPL Single Function Recessed Linear Static White Luminaire - 3

Type: Project: Single Function Recessed Linear Static White Luminaire SPECIFICATIONS Housing Extruded aluminum ceiling trim with cast aluminum endcaps and fabricated 18 gauge cold-rolled steel upper electronics channel housing. Lens Extruded 1/16" translucent opal acrylic snap-in lens profile sealed with closed cell silicone gasket along all four sides. Reflector Formed painted steel with gloss white powder coat; 95% reflectivity. Distribution Symmetric (SYD) with standard lens or 17.5° Asymmetric (ASD, ASDL, ASDR) distribution with standard lens and inner angled boards. Finish Painted in...

Open the catalog to page 3
HPL Single Function Recessed Linear Static White Luminaire - 4

Type: Project: Single Function Recessed Linear Static White Luminaire PHOTOMETRICS Lumen values are from photometric tests from an accredited laboratory. Data is considered to be representative of the configurations shown, within generally accepted industry tolerances. AMBIENT with Asymmetrical Distribution AMBIENT with Symmetrical Distribution Polar Candela Distribution Polar Candela Distribution Lumen Multiplier Table for CCT & CRI *Performance data based upon 35K/90CRI Ambient Nominal Lumens Per Foot This table can be used to approximate the lumen values at different kelvin temperatures....

Open the catalog to page 4
HPL Single Function Recessed Linear Static White Luminaire - 5

Type: Project: Single Function Recessed Linear Static White Luminaire CEILING TRIM F F (Flanged Sheetrock) (Flanged Sheetrock) GB GB (Flangeless Sheetrock Mud-In) (Flangeless Sheetrock Mud-In) MOUNTING Rough-In Dimensions F and GB Ceiling Trims *For more mounting information, please reference the installation instructions. SIZE 24LONG 36LONG 48LONG 72LONG 96LONG NLIGHT AIR ANTENNA IF EQUIPPED NLTAIR2 MODELS ONLY ACCESS PLATE ELECTRONICS CHANNEL GROUNDING POINT 2X 1/2" KO OCCURS ONE END ONLY .875 22 ADJUSTABLE GRID MOUNTING BRACKET 1.17 MIN 30 GRID MOUNTING BRACKETS ACCESS PLATE INCLUDES 2X...

Open the catalog to page 5
HPL Single Function Recessed Linear Static White Luminaire - 6

Type: Project: Single Function Recessed Linear Static White Luminaire DIMENSIONS F NLIGHT AIR ANTENNA NLTAIR2 MODELS ONLY GROUNDING POINT 2X 1/2" KO OCCURS ONE END ONLY .875 22 INSTALLATION CLIPS RJ-45 JACK NLIGHT MODELS ONLY INSTALLATION CLIPS ACCESS PLATE INCLUDES 2X KO ELECTRONICS CHANNEL ACCESS PLATE HOUSING EXTRUSION LENS DIFFUSER LUMINOUS OPENING INSTALLATION CLIPS Trimless Mud-In RJ-45 JACK IF EQUIPPPED NLIGHT MODELS ONLY NLIGHT AIR ANTENNA IF EQUIPPED NLTAIR2 MODELS ONLY MOUNTING HOLES POSITION VARIES WITH MODEL LENGTH GROUNDING POINT 2X 1/2" TRADE SIZE KO .875 22 ACCESS PLATE...

Open the catalog to page 6
HPL Single Function Recessed Linear Static White Luminaire - 7

Type: Project: Single Function Recessed Linear Static White Luminaire LED SCHEMATIC Schematic simplification of lighting options within luminaire, viewed in cross section, facing headwall. ASDL NX INTELLIGENT LUMINAIRE TECHNOLOGY GUIDE Choose Nomenclature from these columns Minimum Dimming Level Dimming Range eldoLED ECOdrive LINEAR DIMMING, TO BE WIRED TO 0-10V CONTROL LINEAR DIMMING, TO BE WIRED TO DALI CONTROL eldoLED ECOdrive eldoLED ECOdrive eldoLED ECOdrive LINEAR DIMMING, RIO EZDL ACWH 90 G2 ANTENNA ON BACK OF LUMINAIRE eldoLED SOLOdrive LINEAR DIMMING, TO BE WIRED TO 0-10V CONTROL...

Open the catalog to page 7
HPL Single Function Recessed Linear Static White Luminaire - 8

Type: Project: Single Function Recessed Linear Static White Luminaire WALL POD Reference spec sheet for nPODMA for complete ordering nomenclature. HPL 2F NLIGHT AMBIENT nPODMA DX (purchase separately) nPODMA DX (purchase separately) NON-IC THERMAL PROTECTOR 2.00 51 LUMEN OUTPUT CONTROL INPUT ZT, DALI, ECOD, NLIGHT, OR NLTAIR2 ZT, DALI, ECOD, NLIGHT, OR NLTAIR2 INSULATION DETECTOR ADDITIONAL DETECTOR Note: BLANK refers to the option not used. E10WLCP option always Non-IC 1.84 47 Healthcare Lighting • (888) 834-5684 • www.healthcare-lighting.com © 2021 Acuity Brands Lighting, Inc. All Rights...

Open the catalog to page 8
HPL Single Function Recessed Linear Static White Luminaire - 9

Type: Project: Single Function Recessed Linear Static White Luminaire NLIGHT & NLTAIR2 DETAILS NLIGHT (Wired) Enabled Network RJ45 Jack Location Typical for all mounting styles (Grid mount shown for reference.) .58 15 RJ45 JACK TO NLIGHT NETWORK NLTAIR2 (Wireless) Enabled Network Antenna Location Typical for all mounting styles (Grid mount shown for reference.) NLIGHT AIR ANTENNA EMERGENCY E10WLCP Specific voltage designation required on fixture when ordering. When fixtures are ordered as a 2F (Dual Fixture Set) and E10WLCP, each fixture will be supplied with an integral battery backup and...

Open the catalog to page 9

All HEALTHCARE LIGHTING catalogs and technical brochures

  1. STRATUS

    1 Pages

  2. ARCHER LED

    1 Pages

  3. TRILUME

    1 Pages

  4. OMNILUME

    1 Pages

  5. CHRYSALITE

    1 Pages