OMNILUME
1Pages

{{requestButtons}}

Catalog excerpts

OMNILUME - 1

Intended Use The louvered patient lighting section of the fixture is designed for bi-level switching so that the patient can easily select lighting that is comfortable for their purpose. Light levels can be controlled via the nurse call system, if wired to the low voltage controller in the fixture, or using a separate pendant pillow switch (optional). A center basket style is also offered as an alternative to the louvered design. (Consult factory.) Features Patient and caregiver lighting with separate controls Motorized exam head (optional) sweeps 0-60° with wall control, included PRODUCT INFORMATION Greater than 250fc light delivered across entire bed surface when head is positioned throughout range of motion 100 CRI exam lighting LED chart/observation light (optional) Entirely serviceable from within the room ORDERING INFORMATION Specifications subject to change. Exam Type Mounting Voltage Ambient lamping Ambient control Ambient circuits MA Motorized (includes LVM) FA Non-Motorized TAI Translucent Acrylic (Standard) PAI Perforated Acrylic Insert (Recommended for Patient Rooms) LVA Low Voltage Controller (FA adder) LV1A LVC with J-box and Pillow Switch (FA) GW Gloss White (Standard) AM AntiMicrobial White LVMJPS - 1-gang J-box with pillow switch (MA Only) LVMEC - Remote pendant exam control (MA only) LVMJPSEC - Both LVMJPS and LVMEC (MA only) 1 Circuit ambient 2C 2 Circuit bi-level ambient ADEZ Mark X Dimming ballast 5-100% phase control ADZT Mark VII Dimming ballast 0-10V low voltage dimmer ADDITIONAL INFORMATION LED Chart Light on Right LED Chart Light on Left MR11 Chart Light on Right MR11 Chart Light on Left Fast-Blo Fuse Slo-Blo Fuse LED Night Light Fluorescent Night Light For additional product information, visit www.healthcare-lighting.com. Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions (if provided) are shown in inches unless otherwise noted. 1 Three each 75W MR16 exam lamps included. 2 MA option comes with 4-Circuit Low Voltage Controller and 2-gang wall plate (LVM). 3 LVA and LV1A with FA only - 2 circuit low voltage switch. 4 JPS and EC with Motorized Exam only; when nurse call system unavailable. 5 Ambient dimming only with SX option; controlled by others. 6 Program start ballasts standard. 7 For HPT222LB (2x2), ambient section has louvers with acrylic overlay. HEALTHCARE LIGHTING

Open the catalog to page 1

All HEALTHCARE LIGHTING catalogs and technical brochures

  1. STRATUS

    1 Pages

  2. ARCHER LED

    1 Pages

  3. TRILUME

    1 Pages

  4. CHRYSALITE

    1 Pages