Catalog excerpts
Jazz Chiller System HIGHLIGHTS Quick and easy assembly Intuitive display 5 litre tank with drain tap Cooling power 140W at 0°C Broad temperature range from -20 to 1 00°C Relay control for refrigeration (on/off) Safety features such as visual and audible alarm User calibration function for optimum accuracy at the required operating temperature Ideal for maintaining operating temperatures during IEF Jazz Chiller can be utilized to maintain optimal operating temperatures of IPG strips (20° C) and precast gels (4°C) during IEF (isoelectric focusing) application. It is a recirculating chiller with easy and quick assembly. Simply connect the chiller to the cooling plate via snap-lock connectors. The thermostat is mounted readily on the refrigerator with insulated tubing and clips. Jazz Chiller is suitable for both immersing samples and circulating temperature controlled fluid to external devices. It is equipped with an immersion thermostat that integrates Intelligent Control Optimisation for adaptive intelligent PID temperature control. Jazz Chiller also comes with a robust integral pump, intuitive timer function and variable high temperature alarm setting. For convenience and safety purpose, the temperature range and heater power are automatically limited based on the liquid type selected. Clear digital display and intuitive controls with intelligent PID temperature control For research use only. Not for use in diagnostic purposes. All images are for illustration purpose only, actual products might differ from the pictures above. Subject to technical changes. Hercuvan Lab Systems Sdn Bhd T * +6 03 8025 1603 F *+6 03 8025 1637 E • info@hercuvan.com W • www.hercuvan.com E hercuvan (ffl hercuvan 1/2
Open the catalog to page 1TECHNICAL DATA Specifications Jazz Chiller System Temperature range Setting display resolution Temperature display Temperature control Cooling power Pump capacity flow rate Pump capacity flow pressure (bar) Bath opening /bath depth (W x L / D cm) Pump connections Temperature stability Filling volume (L) Refrigerant stage 1 Filling volume refrigerant stage 1 (g) Global warming potential for R134a Carbon dioxide equivalent stage 1 (t) Heating capacity (kW) Visual and audible alarm Ambient temperature Bath tank Bath cover Cooling of compressor Included with each unit Weight (kg) Dimension (W x...
Open the catalog to page 2All Hercuvan catalogs and technical brochures
-
Hercuvan Mini Catalog 2019
11 Pages
-
ND-3800-OD
4 Pages
-
Melody Power Supply Series
2 Pages
-
TT-1500 Microplate Shaker
2 Pages
-
Product Catalog 2019
192 Pages
-
TT-14500 PRO Microcentrifuge
2 Pages