HiCen GT - Large Volume Table Top centrifuge
12Pages

{{requestButtons}}

Catalog excerpts

HiCen GT - Large Volume Table Top centrifuge - 1

HiCen*(qT Universal High-Speed Benchtop Centrifuge Large Volume up to 4 x 1,000 ml

Open the catalog to page 1
HiCen GT - Large Volume Table Top centrifuge - 2

For large Volumes, high Throughput and High-Speed-Centrifugation > High-Speed Centrifuges with Flexible Axis! o This provides the best smooth running. o The separation of the own centering of the motor and the centering of the installed rotor protects the bearing of the entire drive system. o Thus, your centrifuge will be maintenance free for a very long time. Voltage Phases Hz 21 11 150 HiCen GT, Standard for Europe - w./o. refrigeration 230 V 1 50/60 Hz 15 angle rotors, 4 swing-out rotors, max. capacity 4 x 1,000 ml speed: 500 - 14,000 rpm, in steps of 100 rpm g-force (RCF): 21,913 x g,...

Open the catalog to page 2
HiCen GT - Large Volume Table Top centrifuge - 3

Angle Rotors (with hermetically sealing lid) Cat. No. Type Max. Capacity Angle Accessories Cat. No. Accessories 25 80 60 Rotor stand for all rotors with conical hub 25 80 70 Cleaning brush for all rotors with bores of 50 ml 25 80 80 Cleaning brush for all rotors with bores of 14/15/16 ml 25 80 90 Cleaning brush for all rotors with bores of 250/290 ml 25 80 20 Extractor tool for 50 ml tubes with rim 25 81 20 Extractor tool for bottom pad for bottles 25 81 60 Tool M4 for the extraction of adapters out of rotors 25 80 30 Tool M6 for the extraction of adapters out of rotors For detailed...

Open the catalog to page 3
HiCen GT - Large Volume Table Top centrifuge - 4

Specification Catalog-No. (230V, 50/60 Hz, 1 Phase) Maximum Capacity Maximum Speed Max. g-Force/RCF (depending on rotor) Minimum Speed Rotor Detection Program Memory Display User Interface Preset Time Preset Speed Preset g-Force/RCF Drive System Speed Accuracy Acceleration Time (depending on rotor) Deceleration Time (depending on rotor) Acceleration/Deceleration Rates Braking System Temperature Set Range Cooling at Standstill Temperature Control Accuracy Temperature Control System Sample Protection Overtemperature Protection Refrigeration System HiCeri\ 21 11 150 4 x 1,000 ml 14,000 min-1...

Open the catalog to page 4
HiCen GT - Large Volume Table Top centrifuge - 5

Tubes and Adapters for Rotors of HiCeritqT for Rotors AF 24.2 + AF 72.2

Open the catalog to page 5
HiCen GT - Large Volume Table Top centrifuge - 6

Tubes and Adapters for HiCeri(qT for Rotor AF 8.50.1 + AF 8.50.2 + A 12.17 Tubes

Open the catalog to page 6
HiCen GT - Large Volume Table Top centrifuge - 7

Tubes and Adapters for HiCefi (qT for Rotor AF 6.250 for Rotor AF 6.500 Bottles * For safety reasons always use 500 ml bottles with collar support ring. (Catalog No. 25 52 41)! ** Use the 0 98 mm bottles in fixed angle rotors for 98 mm 0 bottles only with cover including support ring. For rotors for 100 mm 0 bottles the stainless steel cup 25 13 511 should be used as an adaptger. Attention: Then pay attention to the total weight per bore! The 100 mm bottles are wide-mouth bottles with an opening of 70 mm.

Open the catalog to page 7
HiCen GT - Large Volume Table Top centrifuge - 8

Tubes and Adapters for HiCerj (qT for Rotor AF 6.94 + A 8.20 94 ml Adapter for tubes (38.5 ml), 17 ml, 13.5 ml, 6.5 ml and 4.4 ml are available on request. AS 4.750 + AS 4.1000 with set of Microtiter Plate carriers Microtiter Plates

Open the catalog to page 8
HiCen GT - Large Volume Table Top centrifuge - 9

Tubes and Adapters for HiCe/i GjT for Rotor AS 4.500 Tubes/Bottles Tubes 0 x Length (mm) Material of Tubes + Herolab Cat. No. 50 ml Falcon 29 x 118 Tubes not available from Herolab 15 ml Falcon 17 x 122 Tubes not available from Herolab Necessary Adapter Herolab Cat. No. Tubes per Adapter / Rotor (Pack of 2 Adapters) for Rotor AS 4.750 + AS 4.1000 with set of rectangular buckets for tube racks Tubes

Open the catalog to page 9
HiCen GT - Large Volume Table Top centrifuge - 10

for Rotor AS 4.750 + AS 4.1000 with set of round buckets for bottles or adapters Tubes/Bottles * For safety reasons always use 500 ml bottles with cover support ring (Cat. No. 25 52 41)!

Open the catalog to page 10
HiCen GT - Large Volume Table Top centrifuge - 11

Herolab Tubes for Rotors of HiCenfqT Cat. No. Description 25 10 10 Tubes 3 ml Duran Glass, RB 25 10 20 Tubes 5 ml Borex Glass, RB 25 10 40 Tubes 10 ml Duran Glass, RB 25 10 60 Tubes 10 ml Duran Glass, C/G 25 11 00 Tubes 12 ml Borex Glass, RB 25 11 10 Tubes 30 ml Borex Glass, RB 25 12 60 Tubes 45 ml Borex Glass, RB 25 12 70 Tubes 200 ml Duran Glass, RB 25 20 50 T ubes 1.5 ml PP-CB with lid (Eppendorf) 25 24 01 Tubes 10 ml PC-AOR with screw cap 25 24 11 Tubes 10 ml PPCO-AOR with screw cap 25 24 41 Tubes 10 ml PE-AOR with screw cap 25 24 51 Tubes 10 ml PF-AOR with screw cap 25 29 51 Tubes 30...

Open the catalog to page 11
HiCen GT - Large Volume Table Top centrifuge - 12

25 34 21 Bottles 250 ml PPCO-FB with screw cap 25 34 31 Bottles 250 ml PE-FB with screw cap 25 34 39 Bottles 250 ml PF-FB with screw cap 25 34 41 Bottles 250 ml PC-RB with screw cap 25 34 43 Bottles 250 ml PP-RB with screw cap 25 34 45 Bottles 250 ml PPCO-RB with screw cap 25 34 47 Bottles 250 ml PE-RB with screw cap 25 34 49 Bottles 250 ml PF-RB with screw cap 25 34 81 Bottles 290 ml PC-FB with screw cap 25 34 87 Bottles 290 ml PE-FB with screw cap 25 35 01 Bottles 500 ml PC-FB with screw cap 25 35 12 Bottles 500 ml PP black-FB with screw cap 25 35 21 Bottles 500 ml PPCO-FB with screw cap...

Open the catalog to page 12

All Herolab GmbH Laborgeräte catalogs and technical brochures

  1. HeroDoc plus

    2 Pages

  2. HiCen T / TR

    8 Pages

  3. HeroDoc plus

    2 Pages

Archived catalogs

  1. Printers

    1 Pages