HICREN (Zhejiang) Medtech Co., Ltd. was established in 2011. The company's team adheres to the core values of "Innovation, Passion, Efficiency, Carefulness, Happiness, Sincerity, Cooperation, Empathy, Debrief, and Perceptiveness", striving to establish HICREN as an innovative enterprise focused on building a robot-empowered digital minimally invasive orthopedic platform. HICREN is the first company in China to obtain Chinese and EU approvals for curved vertebroplasty and kyphoplasty products. It is also the most comprehensive manufacturer of surgical instruments for both curved and traditional vertebroplasty...
Open the catalog to page 2PERCUTANEOUS CURVED
Open the catalog to page 3Curved Balloon • Finite element analysis of the comparison between traditional PKP and PCKP technique
Open the catalog to page 4PERCUTANEOUS CURVED VERTEBROPLASTY SYSTEM (PCVP)
Open the catalog to page 5CONTROL THE DIRECTION OF BONE CEMENT EXUDATION MULTIPOINT INJECTION FROM POINT TO FACE REDUCE THE LEAKAGE RATE OF BONE CEMENT • Anterior injection effectively avoids leakage in the intervertebral space and spinal canal direction.
Open the catalog to page 6VERTEBROPLASTY AND KYPHOPLASTY SYSTEM
Open the catalog to page 7Bone Cement Filler Two types of bone cement outlets are available for selection, with a front opening for convenient use and a side opening for directional injection of bone cement. Indications • Used as a supporting tool for percutaneous vertebroplasty and kypho-plasty in medical institutions. Infections, hemorrhagic diseases, unstable fractures or accompanied by spinal cord and nerve root injuries, extremely severe vertebral compression fractures, inability to establish working channels, and concurrent lesions in the same area that require surgical treatment, pedicle fractures; Severe compression...
Open the catalog to page 8STERILE BIOPSY NEEDLE
Open the catalog to page 9Internal thread design of the cannula to ensure higher biopsy rate METHOD OF USE The sterile biopsy cannula is inserted clockwise along the working channel and pushed into the designated position in the vertebral body, the cannula handle is rotated left and right several times and then withdrawn from the working channel, and the bone tissue is pushed out of the cannula with the trocar assembly to complete the sampling. Used for bone tissue biopsy during percutaneous vertebroplasty and kyphoplasty, and other minimally invasive interventional orthopedic procedures.
Open the catalog to page 10PMMASPINAL BONE CEMENT
Open the catalog to page 11• Outstanding physical properties, compressive strength, bending strength, and elastic modulus all comply with international standards. • Good operational performance, suitable dough time, providing sufficient operating time for clinical use • Stable safety performance with medium viscosity, effectively reducing the risk of bone cement leakage • Excellent observation performance, bone cement is radiopaque before and after solidification, which is conducive to intraoperative observation. • T reatment of vertebral compression fractures caused by osteoporosis • Vertebral tuberculosis, bacterial...
Open the catalog to page 12Soft silicone material[ fits snugly against the patient's skin; and ensures precise positioning. nxm p ja.li raxo ta■ jppa tyiqH IQQSfi & Distinctive markers for quick identification of head/foot and left/right orientations. Sterile packaging, designed for intraoperative positioning Radiopaque material added for enhanced visibility under imaging. PRODUCT INDICATIONS This product is primarily used for marking and positioning before or during surgical procedures.
Open the catalog to page 14ANTERIOR CERVICAL PLATE SYSTEM
Open the catalog to page 15SCREW ANGLE DESIGN Large screw angle design is convenient to operate on patients with upper cervical vertebra Flexible selection of adjustable angle and fixed angle screws to achieve multi-mode fixation ECCENTRIC CAM LOCKING MECHANISM The eccentric cam deforms with rotation and forms a gradually pressurized state with the screw Eccentric precision locking With the torque handle, the locking state is controllable PIN HOLES FOR TEMPORARY FIXATION DESIGN OF CANCELLOUS BONETHREAD Increase the holding force of the screw More stable SELF-HOLDING FUNCTION OF SCREWLOW PROFILE DESIGN Temporarily Fix Plate...
Open the catalog to page 16CERVICAL FUSION CAGE
Open the catalog to page 17Superior Convex Design Fit the lower end plate of the upper vertebral body to achieve anatomical fit 15.5mm Width Pyramidal T eeth Structure Enlarge the supporting surface Prevent migration and without damaging the uncinate joint achieve primary stability Lordotic Angle 8° Decompression Slots Hyper Bone Grafting Window Restore cervical physiological lordosis Reduce pressure during Increase the amount of bone graft implantation Increase bone graft area Improve the fusion rate Arc Connection Surface Make the connection between inserter and cage more stable and prevent rotation Convenient implantation...
Open the catalog to page 18POSTERIOR SPINAL FIXATION SYSTEM
Open the catalog to page 19DIFFERENT TYPES OF PULL-UP REDUCTION INTERFACE Provide multiple reduction modes to meetthedifferentrequirementsunder different operatingscenarios Significantly reduce the space occupation under the rod and the transverse space occupation of the screw base Reduce the irritation to the surrounding soft tissue Greatly increase the contact area between the threads and the pedicle and effectively improve the pullout force of the screw Provide implant guidance function Self-tapping full thread design The thickness of the screw wall is increased and the strength of the screw wall is improved while reducing...
Open the catalog to page 20MECHANICALLY STRENGTHENEDTHREAD Greatly increase the contact area between screw and pedicle Effectively improve the pullout force of screw Provide implant guidance function Self-tapping is realized by full thread Convenient loading and unloading, the outer diameter is consistent with the screw, and the incision is smaller C-Shaped screw base, which strengthens the connection stability and makes the rod passing easier • BONE CEMENT MIS SCREW The optimized outlet design of bone cement can effectively improve the distribution effect of bone cement and make the holding effect of screws in the vertebral...
Open the catalog to page 22LUMBAR FUSION CAGE
Open the catalog to page 23Optimized Bullet Structure Convex support surface ThreeTantalum MarkerPins Easy to implant Fittheupperand lower endplates Convenient to observe More in line with the human anatomical structure the cage position Facilitate fusion Add an Impacting Device at the End of the Inserter Impact the protection device to avoid the thread damage of the cage caused by directly striking the inserter shaft PyramidalTeeth The Design of Beveled Prevent migration Edge on the Teeth Side Achieve primary Prevent the end plate fracture caused stability of implantation by stress concentration during the contact between...