1. Catalogs
  2. Hingmed Medical
  3. Hingmed CPAP Machine Without Sound Abatement Foam

Hingmed CPAP Machine Without Sound Abatement Foam

Hingmed CPAP Machine Without Sound Abatement Foam
1 / 72 PagesView full catalog

Hingmed CPAP Machine Without Sound Abatement Foam

Product catalog summary
Pressure Settings and Functionality:
The device reduces pressure during initial exhalation and returns to the set expiratory pressure. It features a Comfort mode with adjustable humidity levels from 1 to 8, auto, or off, where higher levels increase humidity output. The humidifier heats the water tank base to generate vapor, enhancing gas humidity.

Heated Tube and Auto Functions:
The heated tube operates between 16–30°C and includes an auto-start/stop feature that activates ventilation after 2–3 breaths when the mask is worn and stops when removed. A heated tube detection prompt can be disabled when using a standard tube.

Comfort Mode Features:
This mode includes a mask fit check function to monitor mask leakage and provide real-time prompts. Apnea alarm settings range from off to 30 seconds, with alarms for high leaks and mask port blockages. A humidifier empty alarm triggers if the humidifier is empty during therapy.

Mode Settings:
The device offers seven modes: two single-level (CPAP, APAP) and five bi-level modes (S, T, ST, Auto-S, Auto-ST), with advanced options like VA, ASV, and APCV. Single-level ventilators provide constant pressure, while bi-level ventilators allow independent adjustment of inspiratory and expiratory pressures.

Mode Descriptions:
  • CPAP Mode: Provides continuous airflow at set pressure, suitable for upper airway obstruction and OSAHS.
  • APAP Mode: Auto-adjusts pressure based on apneas and hypopneas, beneficial for patients without prior titration.
  • S Mode: Allows independent setting of IPAP and EPAP, triggered by spontaneous breathing.
  • Auto-S Mode: Similar to S mode but auto-adjusts IPAP and EPAP based on airway resistance.
  • T Mode: Bi-level timed control ventilation, independent of spontaneous breathing, suitable for patients without spontaneous breathing.
  • ST Mode: Switches between S and T modes based on spontaneous breathing, suitable for severe OSA and neuromuscular diseases.
  • Auto-ST Mode: Auto-adjusts IPAP and EPAP, suitable for respiratory failure and COPD.


Advanced Modes:
  • VA Mode: Adjusts inspiratory pressure to maintain tidal volume, suitable for central apnea and unstable ventilation.
  • ASV Mode: Adjusts inspiratory pressure to maintain minute ventilation, used for central sleep apnea.
  • APCV Mode: Controls inspiratory time, suitable for high respiratory rate and low tidal volume patients.
See more

Catalog excerpts

Hingmed CPAP Machine Without Sound Abatement Foam-1

Hingmed CPAP Machines

 Open the catalog to page 1
Hingmed CPAP Machine Without Sound Abatement Foam-4

About Hingmed About Hingmed 点击在此录入上述图表的综合描述说明,在此录入上述 礼仪 Established in 2014,Hingmed is a high-tech enterprise engaged in 图表的综合描述说明。在此录入上述图表的综合描述说 the research,development, and production of medical equipment 明,在此录入上述图表的综合描述说明, 对象性 including Blood Pressure Monitors and Ventilators. Hingmed products are CE-approved,has passed ESH clinical validation,and recommended by authorities including “ the Dabl Eudcational Trust ” and “ Stride BP ”. Hingmed focuses on technology research and development. In the past 10 years,we have

 Open the catalog to page 4
Hingmed CPAP Machine Without Sound Abatement Foam-5

Company Area - Hingmed Factory Area: 1000㎡ office + 2000 ㎡ workshop - Production Lines: 3 - Monthly Production Capacity: 30,000 units Hingmed Team - Staff: 90 staffs - Professor: 3 - Algorithm Engineer (PhD): 3

 Open the catalog to page 5
Hingmed CPAP Machine Without Sound Abatement Foam-6

Corporate Culture Corporate Vision: Make everyone healthier ! Provides advanced BP monitoring & respiratory technologies & products to make people healthier. Excellent Service: Close cooperation and full participation.

 Open the catalog to page 6
Hingmed CPAP Machine Without Sound Abatement Foam-8

Hingmed is the first company to adopt H12grade HEPA (High-Efficiency Particulate Air) filters. Hingmed's filter effectively captures particles as small as 0.3 microns, achieving 99.5% filtration efficiency.

 Open the catalog to page 8
Hingmed CPAP Machine Without Sound Abatement Foam-9

Advantages Heating tube 01 The air tubing connection features 180° rotation capability to prevent pipeline damage. 02 The integrated heating air tubing offers greater convenience compared to the traditional split-type configurations.

 Open the catalog to page 9
Hingmed CPAP Machine Without Sound Abatement Foam-10

Power cord 01 Hingmed adopts to 90° angled power cord connectors Compared to traditional straight power cords, to get a more secure connections and reduce loosening risks. Hingmed has innovatively designed a cable fixation slot on the rear panel of the ventilator, which securely locks the power cord to effectively prevent interface loosening or damage caused by device movement.

 Open the catalog to page 10
Hingmed CPAP Machine Without Sound Abatement Foam-11

Advantages Water tank Hidden water tank with one-touch release, The detachable water tank offers superior deformation more convinient. resistance compared to traditional hinged structures. While hinged design is easy to spill water,the separable design effectively prevent leakage.

 Open the catalog to page 11
Hingmed CPAP Machine Without Sound Abatement Foam-12

Advantages Interface Advantages The big 5-inch screen displays the frequently-used functions ensures easier operating.

 Open the catalog to page 12
Hingmed CPAP Machine Without Sound Abatement Foam-13

Advantages Resistance Silencing Technology, No Sound Abatement Foam. No need to worry about pipeline aging particles into the airway,affecting patients’ health and safety. Risks of Sound Abatement Foam Traditional ventilators often place sound abatement foam inside the airwa y system to reduce noise. However, as this material ages, it can release pa rticles that may harm human health. These particles can enter the lungs t hrough the mouth and nose, potentially leading to lung diseases such as pulmonary calcification.

 Open the catalog to page 13
Hingmed CPAP Machine Without Sound Abatement Foam-14

Advantages Respiratory event monitoring technology Discrete Fourier Transform(DFT) Forced Oscillation Technology(FOT) FOT is a method used to identify central sleep apnea and obstructive sleep apnea. Main Principle: When a patient's apnea event is detected, a pressure oscillation signal with a known frequency and amplitude is superimposed on the output pressure. The airway's openness or closure is then determined based on the airflow feedback signal induced by the pressure oscillation. If the airway remains open during apnea, the event is classified as central sleep apnea; if the airway is closed,...

 Open the catalog to page 14
Hingmed CPAP Machine Without Sound Abatement Foam-15

Advantages HINGMGD Auto Start-Stop No need to manually press the button to measure, just put on the mask to automatically enter the ventilation mode

 Open the catalog to page 15
Hingmed CPAP Machine Without Sound Abatement Foam-16

Humidification level The humidification level is divided into 8 levels, and you can also choose automatic and intelligent humidification

 Open the catalog to page 16
Hingmed CPAP Machine Without Sound Abatement Foam-17

Advantages Event Warning If suffocation, high leakage, mask hole blockage, or humidifier is out of water, an alarm will appear on the page. Suffocation Alarm High Leakage Alarm Mask Blockage Alarm Humidifier Waterless Alarm

 Open the catalog to page 17
Hingmed CPAP Machine Without Sound Abatement Foam-18

Installation & Usage

 Open the catalog to page 18
Hingmed CPAP Machine Without Sound Abatement Foam-19

Disassembly process Filter remove 1. Rotate the air intake cap counterclockwise until the hollowedout point faces the unlock icon and remove it. 2. Place your finger inside the filter and snap it out.

 Open the catalog to page 19
Hingmed CPAP Machine Without Sound Abatement Foam-20

Installation Process Filter installation 1. Place the filter into the air inlet. 2. Push the filter inward. 3. Align the cutout on the air inlet cap with the unlock icon and close the cap. 4. Turn the air inlet cap clockwise until the cutout aligns with the lock icon.

 Open the catalog to page 20
Hingmed CPAP Machine Without Sound Abatement Foam-21

TF card installation & removal Open the waterproof cover on the right side of the machine,the topmost slot is the TF card slot.Make sure the chip faces left,press it all the way down and release it. It will spring back, indicating it's securely installed.Press it again and the TF card will pop out. Remark: 1). Please use the TF card from the Hingmed Origical factory,otherwise it will not be recognized. 2). Do not remove the TF card while the device is powered on, as this may damage the card. Serial port The middle and lower parts are serial port connectors, which can only be used to connect end-tidal...

 Open the catalog to page 21
Hingmed CPAP Machine Without Sound Abatement Foam-22

Heating tube installation Take out the heating pipe and plug one end into the ventilator. Note that the type-c interface of the pipe must be aligned with the type-c interface of the ventilator pipeline connection interface. If you need to unplug it, press the white dots on both sides and pull it out. Insert the mask connection into the other end of the heating tube until it stops. If you need to pull it out, grab the silicone part of the heating tube and the nasal mask connection with one hand, and shake it left and right to pull out th nasal mask.

 Open the catalog to page 22
Hingmed CPAP Machine Without Sound Abatement Foam-23

Nasal mask wearing Step 1: Put on the upper headbans,about one finger below the top of your head. Step 2: Put on the nasal mask. Step 3: Secure the left and right buckles, just below your earlobes. After fitting, it should look like the picture. If it is too tight or too loose, all four sides can be adjusted. The distance between the headband and the face is about one finger. Note: If the adjustment is too loose, it may cause increased leakage. Note: The ventilator is set to automatically start and stop by default, so it will automatically enter ventilation mode after putting on the mask. If...

 Open the catalog to page 23

All Hingmed Medical catalogs and technical brochures

  1. ABPM software

    39  Pages

  2. ABP-03

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.