video corpo

FluoroMax Plus

FluoroMax Plus
1 / 20 PagesView full catalog

FluoroMax Plus

Product catalog summary
Introduction
The FluoroMax Series by HORIBA offers high-performance spectrofluorometers in a bench-top model, known for sensitivity and flexibility. It includes the FluoroMax-4 and FluoroMax Plus, featuring Time Correlated Single Photon Counting (TCSPC) for advanced measurements.
Sensitivity and Performance
Designed for high sensitivity, the FluoroMax series detects small changes and dilute samples using reflective optics and photon counting to maximize signal and minimize noise. It provides RMS and FSD measures for signal-to-noise ratio, ensuring reliable sensitivity comparisons.
Dynamic Range and Measurement Capabilities
The FluoroMax measures a wide range of signal levels, crucial for kinetic studies, and allows for absolute quantum yield measurements using the Quanta-φ integrating sphere accessory.
Enhanced Measurements and Flexibility
The series supports enhanced measurement techniques like absorbance/transmittance, polarization, and microvolume measurements. Accessories such as Microsense and MicroMax 384 enable high-throughput data collection and analysis of ultra-low sample volumes.
Temperature Control and Accessories
Offering precise temperature control options, including Peltier-based and cryogenic systems, the series supports a wide range of experimental conditions. Accessories extend the instrument's utility, including auto-titrators, stopped flow systems, and fiber optic probes.
Advanced Detection and Lifetime Measurements
The FluoroMax Plus model extends the spectral range with additional detectors and gratings, supporting lifetimes as short as 25 ps. The DeltaTime TCSPC accessory allows rapid lifetime measurements, enhancing kinetic studies and providing robust data independent of concentration and photobleaching.
Specifications
The FluoroMax series includes models with optional pulsed xenon flash lamps for lifetime measurements as short as 10 μs. Features include all-reflective optics, a 150 W ozone-free xenon arc lamp, and Czerny-Turner monochromators. Key specifications include a wavelength accuracy of ±0.5 nm, integration times from 1 ms to 160 s, and a water Raman signal-to-noise ratio of 16,000:1 (RMS method).
Software
FluorEssenceTM software is designed for both occasional and advanced users, offering method development, data collection, analysis, and report generation. It supports automation of experiments and includes data reduction tools through OriginProTM, such as peak finding, curve fitting, and normalization.
Applications
The instruments are suitable for complex solutions, such as mixtures of Bovine Serum Albumin and Terbium Chloride, where the phosphorescence option allows for temporal gating to isolate specific signals. They are ideal for applications involving lanthanide-tagged samples or rare earth phosphors.
Contact Information
The document lists contact details for HORIBA offices worldwide, including the USA, France, Japan, Germany, Italy, the UK, China, and Brazil.
See more

Catalog excerpts

FluoroMax Plus-1

FluoroMax Series Sensitive, flexible, easy-to-use fluorometers Powerful technology with bench-top convenience

 Open the catalog to page 1
FluoroMax Plus-3

“With unmatched sensitivity and unparalleled flexibility, the FluoroMax Series can meet all of your lab’s experimental needs.” FluoroMax Series The FluoroMax series represents HORIBA's industry-leading spectrofluorometer performance in a convenient, affordable, easy to use bench-top model. The FluoroMax family, with its unique all reflective optics and photon counting, was the first to bring the sensitivity of a modular fluorometer to a tabletop unit. Today the FluoroMax series consists of the FluoroMax-4, the latest generation of the original, high performance tabletop fluorometer, and the new...

 Open the catalog to page 3
FluoroMax Plus-4

Maximizing signal, Minimizing noise the sensitivity of one instrument to another with the multiple specifications and differing definitions that pervade. Sensitivity of a spectrofluorometer is generally reported as a minimum measureable concentration of a fluorophore (commonly Fluorescein), or the signal- to-noise ratio (S/N) of the Raman scattering peak of water. Most companies opt for the second, as it is a more readily verified number, especially in the field. Unfortunately, however, this specification can be confusing since two calculation methods prevail in the industry: First Standard Deviation...

 Open the catalog to page 4
FluoroMax Plus-5

Dynamic Range Measure more than 6 orders of magnitude of signal levels in the same spectrum Fortunately not all samples are weak. Some samples are quite strong. But some are both, which creates a challenge to measure the strong and weak peaks in the same scan. With an intra-spectral range of over 6 orders of magnitude, even wildly varying multicomponent spectra are no problem to measure in one scan. Not only does this save time, but it is essential for kinetics studies when one cannot afford to repeat a measurement at different integration times to keep all peaks within range. Spectrum of a mixture...

 Open the catalog to page 5
FluoroMax Plus-6

Measuring temporal variations in fluorescence spectra can yield information beyond that available from single time point measurements. For example, monitoring protein stability and folding in controlled solution conditions is crucial for developing targets for structure-based medicines. The FluoroMax series lets you measure dynamics on a scale of Kinetics of Lysozyme dissolved in several concentrations of the chaotrope; Guanidiniurn Hydrochloride, monitored by measuring native Tryptophan fluorescence simultaneously for 1 hour in a multi-sample changer. Data corrected for photobleaching using...

 Open the catalog to page 6
FluoroMax Plus-7

Adding optional polarizers to a FluoroMax allows measuring anisotropy, and hence, the changes in sample rotation time. This indirect measure of the local viscosity gives information on sample aggregation, structural changes, molecular binding, and other mechanisms. Absorbance/Transmittance Accessory Add absorbance to your fluorescence measurement. Correct your fluorescence spectra for innerfilter effects in concentrated samples without dilution. Reabsorption of fluorescence photons can occur even at moderate concentrations, and lead to increasing distortion of spectra with increasing concentration...

 Open the catalog to page 7
FluoroMax Plus-8

Microvolumes Measure ultra-low sample volumes with easy sample recovery HORIBA’s Microsense, the most advanced microliter accessory on the market, is designed to get cuvettequality steady state or lifetime data from a 1-5 µL of sample. Avoiding dilution and nearly total recovery minimizes the need for sample, while preserving measurement sensitivity. Based on all quartz optics, Microsense is compatible with UV to NIR measurements. Using the Microsense, 5 µL of AlexaFluor 488 labeled IgG is enough to get steadystate or TCSPC data. Well Plate Accessory Maximize your throughput Search for “hits”...

 Open the catalog to page 8
FluoroMax Plus-9

Full Spectral Microscopy Couple a microscope to a FluoroMax and: • Measure a complete spectrum of a sample as small as 1 µm. • Get spectra from as little as a few molecules of sample. • Perform localized FRET measurements. Add an automated stage and camera, and: • Create complete spatial/spectral maps. • Perform repetitive QC characterization of structured samples like photovoltaics. Enhanced Measurements Data from a real and forged US 5 dollar bill. Fluorescence imaging shows no obvious differences. However it is easy to spectrally distinguish the real from a fake bill. All instruments in the...

 Open the catalog to page 9
FluoroMax Plus-10

Peltier-based Heated/Cooled Cuvette Holders Rapid temperature control in single or multiple cuvette models with built-in magnetic stirring. Precise temperature control for precise data on your protein folding, micellization, solubility, conformation, phase, and rotational transitions. Rapidly vary sample temperature over a range of -40 to 110°C. FluoroMax software also simplifies automating temperature dependence measurements, including complex ramps and profiles. Temperature Bath An alternative to Peltier-based units. Better precision (0.01°C), range (-25 to 200°C) and long term stability, but...

 Open the catalog to page 10
FluoroMax Plus-11

Cryogenic temperatures enable measurements of fine structure, enhanced phosphorescence, and rare conformations/states often not possible at room temperature. This low cost accessory readily permits measurements of samples at 77°K. Economic LN Temperature Measurement Dewar Accessory Temperature can add thermal broadening to fluorescence spectra and increase phosphorescence quenching. Spectra of Naphthalene dissolved in Methanol measured at room temperature (298°K) and in a liquid nitrogen dewar accessory (77°K). The low temperature spectrum reveals rich vibrational structure and longer wavelength...

 Open the catalog to page 11
FluoroMax Plus-12

Other Accessories The FluoroMax series includes the most comprehensive line of accessories that enable researchers to extend the utility of their instrument to as many experiments as possible. The following is a partial list of accessories available, in addition to those previously discussed. • Auto-titrator (injector) dual syringe, dual valve. • Hi-Tech SFA-20 Stopped Flow, rapid kinetics accessory. • Solid Sample Holder designed for viewing front-face fluorescence of thin films, powders, pellets, paper, fibers, or microscopic slides. Variable alignment angle. • 2-position sample holder with...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.