QuantaMaster - 3

“The PTI QuantaMaster series modular design offers reassurance that your system can be easily customized and adapted to your growing research capabilities.” PTI QuantaMaster Series The PTI QuantaMaster series of research grade spectrofluorometers are multidimensional systems for photoluminescence measurements. The foundation of a fluorescence spectroscopy laboratory is built on steady state intensity measurements such as wavelength scans, time-based experiments, synchronous scans and polarization. The PTI QuantaMaster series ensures you get the best possible results for all these...

Open the catalog to page 3
QuantaMaster - 4

Sensitivity The industry standard for sensitivity is a signal to noise ratio calculated from a water Raman spectrum. Using this standardized test (see our technical note "SN Determination for PTI QuantaMaster Fluorometer,") our signal to noise ratio is >20,000:1. The high sensitivity of the PTI QuantaMaster fluorometer is no accident. It is achieved by intelligent engineering of the Xe arc lamp illuminator featuring an ellipsoidal reflector with the highest possible light gathering efficiency of 67%, and focusing the light in a tight spot at the monochromator slit. As a result, the standard...

Open the catalog to page 4
QuantaMaster - 5

Suppression of stray light is one of the most critical factors when measuring highly scattering, or low quantum yield samples. Every PTI QuantaMaster series spectrofluorometer is custom made with the highest quality optics to insure the lowest amount of scatter. The asymmetrical monochromators are coma-corrected and individually optimized for purpose as either excitation or emission monos, ensuring the lowest amount of stray light contamination for the best detection of the true fluorescence signal. The PTI QuantaMaster series boasts an impressively high stray light rejection: >1x10-6 in a...

Open the catalog to page 5
QuantaMaster - 6

Spectral Range and Signal Detection Excitation and Emission Correction For most applications, the typical detector employed is a PhotoMultiplier Tube (PMT). Every PTI QuantaMaster features a highly sensitive PMT, with the option of an analog or digital output. The PTI QuantaMaster Series offers you the ability to customize the system to meet your applications needs. Digital detection, or photon counting, offers the highest sensitivity as it records single photon events. The analog detection measures the current that is generated on the PMT anode, and provides for additional detection gain...

Open the catalog to page 6
QuantaMaster - 7

The QuantaMaster 400 steady state spectrofluorometer is one of the most sensitive bench-top fluorometers on the market today. Its signal to noise is >20,000:1, allowing the minutest traces of fluorescent materials to be detected and identified in samples. It features state-of-the-art high throughput monochromators with a triple motorized grating turret for easy extension of the spectral range, and motorized flipping mirrors to make it easy to work with additional light sources and detectors. Its high performance and open architecture makes it suitable for practically all possible...

Open the catalog to page 7
QuantaMaster - 8

UV VIS Specifications The following specifications are for standard PTI QuantaMaster systems. Options and upgrades may be available upon request. PTI QuantaMaster 400 Signal to Noise Ratio 20,000:1 or better 300: 1500:1 or better 300 Plus: 3000:1 or better 300/300 Plus: 1 point/sec to 300 points/sec 310: Up to 20 points/sec Data Acquisition Rate 4 photon counting (TTL); 4 analog (+/- 10 volts) ; 1 analog reference channel (+/- 10 volts); 2 TTL Emission Range Light Source High efficiency “ECO” friendly continuous Xenon arc lamp 300/300 plus: High power Xenon flash lamp 310: Nitrogen laser...

Open the catalog to page 8
QuantaMaster - 9

Near-infrared (NIR) spectrofluorometry has emerged as a valuable analytical technique, especially in the fields of material research, nanotechnology, chemistry, and photomedicine. Powerful and diverse NIR capabilities are available through PTI as either a stand-alone research grade fluorometer, or as an upgrade to PTI’s UV-VIS steady state spectrofluorometers. There are different configurations to adapt to any research needs. NIR-PMT Based Steady State Systems Comprised of a high intensity continuous xenon light source, scanning monochromators, and a cooled NIR PMT detector. Available with...

Open the catalog to page 9
QuantaMaster - 10

NIR Specifications The following specifications are for standard PTI QuantaMaster systems. Options and upgrades may be available upon request. PTI QuantaMaster 500/ QM-510-Option 500: Singlet oxygen generated by 0.5 µM Rose Bengal in MeOH QM-510-Option: Singlet oxygen generated by 2 µM Rose Bengal in MeOH Light Source High power continuous Xenon arc lamp 300 mm, coma-aberration corrected, asymmetrical, excitation or emission optimized, CzernyTurner design Focal Length Excitation Grating Emission Grating Optional Grating 75–2400 line/nm and holographic models available 75–1200 line/mm and...

Open the catalog to page 10
QuantaMaster - 11

The PTI QuantaMaster series features an open architecture design that provides the ultimate in versatility, allowing your instrument to adapt to your future fluorescence application needs. You can optimize the initial configuration by choosing the light source, gratings, and PMT tubes, as well as a wide array of available accessories. The number of available configurations is virtually limitless! The PTI QuantaMaster universal QuadraCentric™ sample compartment has a spacious design that provides accessibility and can accommodate a wide selection of sample accessories. Choose from sample...

Open the catalog to page 11
QuantaMaster - 12

PTI FelixGX Software PTI QuantaMaster fluorometers come with our own software for the control of the instrument and accessories, which includes analytical functions for trace manipulation, and spectral and kinetic analysis. Through the powerful ASOC10 USB interface, PTI FelixGX provides a full set of data acquisition protocols, and controls the hardware for all system configurations and operating modes. PTI FelixGX Controls Hardware Controls • Monochromators • Triple grating turret • Flipping mirrors switching between different light sources and detectors • Motorized slits • Motorized...

Open the catalog to page 12

All HORIBA Scientific catalogs and technical brochures

  1. Aqualog®

    2 Pages

  2. LA-350

    4 Pages

  3. EMGA-920

    4 Pages

  4. LAQUAtwin

    12 Pages

  5. LA-960V2

    8 Pages

  6. SZ-100

    8 Pages

  7. OpenPlex

    2 Pages

  8. Duetta™

    8 Pages

  9. THz-Raman®

    4 Pages

  10. MINI-CCT+

    2 Pages

  11. EasyLife L

    2 Pages

  12. EasyLife X

    2 Pages

  13. KiloArc

    2 Pages

  14. iHR

    6 Pages

  15. LSH

    2 Pages

  16. PowerArc™

    2 Pages

  17. MacroRAM™

    2 Pages

  18. MicOS

    2 Pages

  19. BRO ICP NEO

    3 Pages

  20. FluoroMax Plus

    20 Pages