Centrifuges
8Pages

{{requestButtons}}

Catalog excerpts

Centrifuges - 1

Centrifuges Catalog

Open the catalog to page 1
Centrifuges - 2

Centrifuge Selection Guide HTI PowerSpin™ This guide should help you choose the right HTI centrifuge for your specific needs. Speed (RPM) vs. g-Force (RCF): The most important factor when choosing a centrifuge is the g-Force, or RCF, not the speed. The RCF determines the ability of a centrifuge to separate the specimen. Most specimens must be spun within a specific RCF range in order to properly prep the sample for testing and analysis. The guide below will help you select a model based on RCF, RPM, # of tubes, specimens and other attributes. Urine Sample Centrifugation: A note of caution...

Open the catalog to page 2
Centrifuges - 3

LX Color Coded Quick Speed setting reference: Brown Fecal Yellow Urine Red Bloody Shown with optional Tube Holdster™ PowerSpin™ Centrifuges, Models FX and LX HTI® PowerSpin™ e compact, economical and quiet. We offer both fixed (FX) and variable (LX) speed models with fixed angle rotors, for 6 or 8 tubes to spin 7.5 -15 ml tubes. By using adapters, you can also spin tubes ranging from 2 - 7 ml. An optional Tube Holdster™ allows you to have up to 18 tubes or adapters at your fingertips, side-mounted on the centrifuge. PowerSpins are pre-drilled/tapped to accept optional Tube...

Open the catalog to page 3
Centrifuges - 4

PowerSpin™ PortaSpin™ Centrifuge, PX Mobile The PortaSpin PX allows you to take your practice on the road. Whether you are a mobile vet, visiting nurse or doctor, we have a PortaSpin that will meet your needs. Available with 6 or 8 place rotors and adapters to fit tubes ranging from 2 - 15 ml. Standard with 12 Volt car lighter adapter, a 110V electrical outlet adapter is optional for use back at the lab. When using this unit you will most likely not be in your lab setting so you will not have you standard bench-top tube rack. We strongly recommend purchasing the optional Tube...

Open the catalog to page 4
Centrifuges - 5

PowerSpin™ Centrifuges, DX HTI® is proud to present the PowerSpin™ DX Centrifuge With 4 rotor options this centrifuge is a great answer for every day laboratory tasks. - 24 place fixed rotor for 2-15ml tubes ( #C8724 ) - 6 place horizontal rotor for 2-15ml tubes ( #C8706 ) - 4 place horizontal rotor for up to 50ml tubes ( #C8704 ) - 4 place fixed rotor for 60ml syringes ( #C8760 ) The PowerSpin™ DX has variable speed 500 – 4000 RPM, to ensure a clean and complete separation. Quiet and dependable, with a maintenance free motor, it can be used to process blood, urine, semen and other...

Open the catalog to page 5
Centrifuges - 6

Model C8724 • 24 place fixed angle rotor ( pn#C8600-03 — rotor only) • Designed to accept 10ml blood tubes and up to 15ml urine tubes • 2ml tubes with small tube adaptor (pn# C800-04 — set of 2) • 5ml tubes with short tube adaptor (pn# C800-03 — set of 10) • 6 place horizontal rotor ( pn#C8600-01 — rotor only) • Specifically designed to keep tubes vertical at rest • Designed to accept 10ml blood tubes and up to 15ml urine tubes • 2ml tubes with small tube adaptor (pn# C800-04 — set of 2) • 5ml tubes with short tube adaptor (pn# C800-03 — set of 10) Model C8760 • 4 place fixed...

Open the catalog to page 6
Centrifuges - 7

PowerSpin™ Centrifuges, BX Item No. Description C881M BX, 6 Place Fixed Angle Metal Rotor Centrifuge C881ME BX, 6 Place, Fixed Angle Metal Rotor Centrifuge, 220V C882 BX, 24 Place Hematocrit Centrifuge C882E BX, 24 Place Hematocrit, same as above, 220V C883 BX, 24 Place Micro-Tube Centrifuge C883E BX, 24 Place Micro-Tube, same as above, 220V C884 BX, 6 Place Tube rotor & 24 Place Microhematocrit C885 BX, All three available rotors, 110V C885E BX, All three available rotors, 220V C886 BX, 24 Place Microhematocrit & 24 Place Microcentrifuge C886E BX, 24 Place Microhematocrit &...

Open the catalog to page 7
Centrifuges - 8

PowerSpin™ Centrifuges, BX PowerSpin™ Centrifuge, BX BX Versatility: New Microhematocrit Tube Adapters: We have developed several microhematocrit tube adapters that can be used with the Blood & Urine Tube Rotor, making a single rotor much more versatile and eliminating the need to purchase an additional rotor, or change rotors. Both New C80034 and C8600-34 Adapters come in a Pkg/2 adapters, each and each adapter holds up to 4 MH tubes. The Blood & Urine rotor runs at a max of 5,000 RPM, much slower than traditional microhematocrit rotors with a 5 min. run. With our adapters, at 5,000 RPM,...

Open the catalog to page 8

All HTI Medical Inc. catalogs and technical brochures