Overview
The HDJ-IV A800 Radiolucent Cranial Stabilization System by Changzhou Huida Medical Instrument Co., Ltd. is designed for use in CT, DSA, MRI, and Fluoroscopy. It is tailored for neurosurgery, spinal, and interventional therapy, offering a metal-free option to minimize imaging artifacts.

Specifications
- Head Clamp (Code: HA82016): Features pressure visualization and a dual pin holder, entirely metal-free.
- Swivel Adaptor (Code: HA83016): Adjustable in horizontal and vertical planes, metal-free.
- Radiolucent Skull Pins (Codes: HA01016 for adults, HA01026 for pediatrics): Titanium pin tip with composite base for optimal imaging.
- Transitional Member (Code: HA84026): 20cm length, metal-free, used with extension member.
- Extension Member (Code: HA84116): 15cm length, metal-free, allows for extended base and angle adjustment.
- Base Unit (Code: HA84106): Universal table clamp compatible with US and European models, adjustable width and pitch angle, partially metal-free.

Features
- Provides stable, high-precision 3-point head fixation during surgery.
- Suitable for both children and adults.
- Offers easy fixation and optimal imaging views in various patient positions (prone, supine, lateral).
- Includes a torque screw for skull pin pressure visualization and a horizontal bar for wide imaging windows.

Accessories
- Radiolucent Headrest & Traction System: Provides good hemodynamic performance.
- Sterilizing Container for Skull Pins (Code: HA01800P): Made of polymer material to protect pin tips during sterilization.

Contact Information
Changzhou Huida Medical Instrument Co., Ltd.
Address: NO.1 Shijiapeng Road, Jincheng Town Industrial Park, Jintan, Jiangsu Province, China
Tel: +86 519 82857858
Fax: +86 519 82857868
Email: [email protected]
Website: www.huidamed.com

All rights reserved by HUIDAMED, version 2021, subject to change.
See more

Catalog excerpts

A800 Radiolucent Cranial Stabilization System-1

HDJ-IV A800 R adiolucent C ranial Stabilization S ystem Design for CT, DSA, MRI, Fluoroscopy

 Open the catalog to page 1
A800 Radiolucent Cranial Stabilization System-2

The new HDJ-IV A800 Radiolucent Cranial Stabilization System is the key step of HUIDAMED in the imaging product field, which focus on Neurosurgery Equipment for over 20 years. It is design for DSA, CT, MRI and Fluoroscopy, aim to meet the clinical demands on neuro, spinal and interventional therapy. The system have a “metal-free” option, plus the synthetic Sapphire-Carbon composite skull pin, could meet the requirement in MRI room and provide a good control on minimal imaging artifact. fixation of the head during surgery. Torque screw make the skull Horizontal bar provides a wide Easy fixation and...

 Open the catalog to page 2
A800 Radiolucent Cranial Stabilization System-3

Head Clamp Pressure visualized. Easy lock dual pin holder. Whole material is metal free. Swivel Adaptor Adjustable on both horizontal and vertical planes. Whole material is metal free. Transitional Member Length 20cm. Make more distance between base unit and swivel adaptor. Use with extension member HA84116. Whole material is metal free. Extension Member Length 15cm. Used when need more length of base and more Angle adjustment range. Use with 20cm transitional member HA84026. Whole material is metal free. Radiolucent Skull Pins Code: HA01016 (Adult) Code: HA01026 (Pediatric) Titanium pin tip...

 Open the catalog to page 3
A800 Radiolucent Cranial Stabilization System-4

Headrest & Traction Code: HA84116 & HA85036 Whole material is metal free. Gel pad provide good hemodynamic performance. Transitional Member Length 15cm. Used when no request on the extension distance. Sterilizing Container (for Skull Pins) Code: HA01800P Made of polymer material. Protect the pins tip when sterilizing. The standard fixation with OT table Radiolucent Headrest Traction System Could provide connect solution for different DSA tabl