HCR 1002 is an advanced technology by Human Tecar aimed at enhancing therapeutic effectiveness through improved microcirculation. It focuses on maximizing recovery, restoring balance, and improving performance from the first session by alleviating pain and discomfort.
Specifications
The HCR device is a new-generation technology featuring a high-efficiency generator and an Advanced Emission System for precise application. It is lightweight at approximately 7 kilograms and allows for flexible temperature adjustments to meet individual therapeutic needs.
Functionality
HCR functions as an electromagnetic stimulator using medium-frequency radio signals to activate metabolic processes in biological tissues, enhancing blood and lymphatic circulation and promoting internal healing without energy loss.
Operational Mechanism
The technology is based on capacitance principles, mobilizing electrolytes to influence cellular metabolism and increase blood flow. It operates on three levels: biostimulation, intracellular oxygenation, and mechanical vasodilation, ensuring a homogeneous response in deep tissues.
Applications
HCR is versatile, applicable in physiotherapy for pain management, sports recovery, anti-aging treatments, and aesthetic medicine. It effectively treats osteoarticular and muscular pathologies, enhances skin revitalization, and addresses conditions like lymphedema and cellulite.
Electrode Technology
The device uses high-impedance (capacitive) and low-impedance (resistive) electrodes to effectively transfer energy to biological tissues, ensuring optimal therapeutic outcomes.
Universal Electrolytic Emulsion
This emulsion is essential for reducing tissue resistance and facilitating electrolyte mobilization, enhancing the therapeutic response and ensuring a pleasant treatment experience.
Conclusion
HCR 1002 represents a significant advancement in therapeutic technology, offering precise, efficient, and flexible treatment options across various medical and aesthetic applications.
Overview of HCR Technology
HCR technology is beneficial in various therapeutic contexts, including stress prevention, chronic condition treatment in the elderly, disability support, veterinary medicine, and sports rehabilitation. It improves rest quality and restores psychological and physical well-being without interfering with pharmaceutical therapies or causing side effects.
Applications in Different Fields
  • The Elderly: Effective in treating chronic conditions such as degenerative and inflammatory joint diseases, osteoporosis, and post-surgery rehabilitation, particularly after arthroplasty.
  • Disability: Enhances quality of life by treating acute and chronic pathologies and aiding in muscular recovery.
  • Veterinary Medicine: Used in treating horses and small animals, reducing therapy time and aiding in muscular recovery before and after intensive training.
  • Prevention: Employed in professional sports and occupational medicine to prevent minor issues from developing into chronic conditions, thereby improving overall well-being.
Technical Characteristics
  • Device Classification: Classified for protection against electrical risk (Class I, Type BF), electromagnetic compatibility (Class A, Group 1), and is a common device for water and dust protection.
  • Intended Use Classification: Includes GMDN Code 47575 for heat treatment by radiofrequency and UMDNS Code 11244 for diathermy units.
  • Technical Data: Operates at 100-240 V, 50-60 Hz with an output frequency of 0.447 MHz. It has specific output voltage and power settings for resistive and capacitive modes.
Manufacturer Information
Unibell srl, located in Calco, Italy, reserves the right to make changes to devices and products. Contact information and trademarks are provided.
See more

Catalog excerpts

HCR 1002-1

The revolutionary technology that maximizes therapeutic effectiveness and speed

 Open the catalog to page 1
HCR 1002-2

HCR is a fundamental tool within the Human Tecar MO: by acting on microcirculation, it maximizes the body’s capacity for recovery, preserves and restores balance, and enhances performance. From the very first session, the person being treated will be able to ascertain the immediate benefits of treatment: pain and discomfort disappear; functional recovery is more easily achieved, fast.

 Open the catalog to page 2
HCR 1002-3

WHAT IS IT? Human Tecar HCR is an electromagnetic stimulator of microcirculation. It works by means of a medium-frequency radio signal (447 kHZ) that, placed in contact with biological tissue through two specific types of conductive electrodes – high and low-impedance – triggers metabolic activation of the tissue itself, stimulating blood flow/lymphatic circulation in more or less extensive body areas. The electromagnetic signal is conveyed to tissue by direct contact, acting from the inside, without any energy loss. HCR is a new-generation technology, the outcome of a quarter of a century of...

 Open the catalog to page 3
HCR 1002-4

HOW DOES IT WORK? The healing process starts from within the body. Stimulating energy from inside biological tissue to activate reparatory, antiinflammatory processes, Technology comes to the aid of the physician to eliminate pain and solve the problem causing it: energy calls for energy. HCR is based on the principle of capacitance, well known in physics and applied to this type of electro-medical device for the first time here. In biological terms, we may speak of the mobilization of electrical charges - called electrolytes - that are naturally present in the body. These can influence cellular...

 Open the catalog to page 4
HCR 1002-5

► Homogeneity of response in deep tissue One of the major advantages to HCR is the homogeneity of response in deep tissue: this is because energy is exclusively conveyed by means of the attraction and repulsion processes of the electrical charges drawn by the active electrode from the various body districts, so it acts from within rather than without the body. ► Flexibility of technology Practitioners can utilize HCR in a very flexible manner, since its use is highly focused and precise, acting locally and prompting variations in temperature in a given body district and therefore, differences...

 Open the catalog to page 5
HCR 1002-6

INFLUENCE ON BIOCHEMICAL PROCESSES STIMULATION OF REPARATORY PROCESSES 100% CONTROL OF INFLAMMATORY PROCESS RECOVERY OF FUNCTIONAL BALANCE PAIN CONTROL CONTROL OF IMMUNE / ENDOCRINE / METABOLIC RESPONSE The basic principle behind HCR technology is homeostatic in nature: stimulating and supporting the body in its self-regulating mechanisms. It’s not a matter of acting in the body’s stead but of stimulating physiological tissue activity from within, supporting the body’s recovery process and triggering its natural anti-inflammatory and reparatory processes. Stimulating the body’s natural processes...

 Open the catalog to page 6
HCR 1002-7

► HCR 1002 - THREE REACTIONS PRODUCED 1. INCREASE IN MICROCIRCULATION Blood Flow Cellular Metabolism Hypoxic hyperemia. Oxygenation. Biostimulation activates beneficial threshold values. Reactivation of metabolic activities. Vascularization and increase in temperature. PATHOLOGICAL TISSUE

 Open the catalog to page 7
HCR 1002-8

Advantages of transferring the entire potential of HCR to biological tissue by means of high-impedance lymphodynamic and thermo-dynamic electrodes (capacitive) and low-impedance electrodes (resistive), in combination with the Universal Electrolytic Emulsion HIGH-IMPEDANCE ELECTRODES Particularly suited to treating soft tissue (muscular, adipose, vascular, lymphatic). High-impedance (capacitive) electrodes induce an endogenous response, contingent on the intensity of the electromagnetic signal applied, reactivating blood flow (minimal or max. variations, depending on goal), in low-impedance soft...

 Open the catalog to page 8
HCR 1002-9

High-impedance (capacitive) electrodes, coated with a special insulating material, are made with a multi-layer coating technique (wafer technology), with one or more biocompatible materials. Their characteristic is transferring the mediumfrequency radio signal to biological tissue in the most effective way possible. The person being treated feels that internal and deep circulation is reactivated, which in turn induces an increase in temperature in the given body district. Convex, high-impedance lymphodynamic electrodes Suitable for inducing small changes in blood flow in tissue, with microscopic...

 Open the catalog to page 9
HCR 1002-10

LOW-IMPEDANCE ELECTRODES Particularly suited to selective, in-depth action; treatment with low-impedance electrodes is currently considered the treatment most effective on fibrous connective tissue and bone tissue, biophysically more resistant tissue (bones, cartilage, large tendons, aponeuroses). Low-impedance or resistive electrodes are powered by the same radiofrequency signal. The practitioner assesses which intensity level he had best apply, depending on the required endogenous response. This consists of concentrating circulation and increasing temperature in osteoarticular and tendinous...

 Open the catalog to page 10
HCR 1002-11

ELECTROLYTIC EMULSION logical treatment. Universal Electrolytic Emulsion Treatment with HCR cannot do without the Universal Electrolytic Emulsion, a functional cosmetic product with high levels of conductivity that constitutes an indispensable factor in reducing superficial tissue's resistance and facilitating the internal mobilization of electrolytes, responsible for the consequent circulatory response. It is a highly technological product that, correctly utilized, strongly affects response time to therapy. It guarantees tissue's thorough hydration, reduces skin resistance, optimizes electrode's...

 Open the catalog to page 11
HCR 1002-12

Pain HCR is effective in the early treatment of all non-surgical osteoarticular and muscular pathologies, acute or chronic. Its action is intensely analgesic; it drains tissue by acting on microcirculation and functionally stimulates peripheral circulation thanks to its modulation of endogenous temperature. Results are swift and stable in time. Facial skin revitalization HCR is conducive to greater hydration of the skin and facilitates the elimination of toxins. Thanks to the internal and homogeneous increase in tissue temperature, it favors new collagen formation, while externally, treatment...

 Open the catalog to page 12