Medical Niti Stent - 1

Abeu 七 Company Hunan Fude Technology Co., Ltd.. was established in 2008. With 12,000 square meters of building area, we also have more than 800 square meters of ISO-Class 8 certified manufacturing area .we have devoted to the field of micropo「t medical devices, especially focused on researching and developing the endoscope accessories and all kinds of stapler. Our existing main products include Disposable Linear Cutter Stapler and components, Disposable Curved Cutter Stapler and components , Disposable Linear Stapler and components, Disposable Automatic Linear Stapler and components , Disposable Circula『 Stapler for hemo「「hoids (PPH ) , Disposable Circular Stapler, Disposable Purse Stapler, Disposable Skin Staple「, Hemorrhoidal Multi-Band Ligato「with Anoscope, Disposable Biopsy Forceps, Disposable Balloon Dilatation Catheter, Ni-Ti Alloy Medical Stent and Introduce「 System, Disposable Cytology Brush, Ligatu「es Endoscopic Loop, Disposable In」ection Needle , etc. Except the product manufacturing cente 「, we also have set up the product research and development center, the mould manufacturing center and testing center. In our company there are mo「e than 10 「esearch persons. Among that two persons a『e senior engineers and several external unive 「sity expe 「ts are f「om china and ab「oad. the mould manufacturing center is equipped with processing center (6 sets), Sodick slow walking wire cutting equipment (4 sets), quick walking wire cutting equipment (8 sets), Sodick mirror EDM equipment (1 set), common EDM equipment (6 sets), and general machine tools (turning, m仙ng, grinding, drilling, etc. more than 10 sets). Our testing center has the ab山ty of conventional biological detection and physical detection. In addition of that, we also have Ge「many Zeiss three coordinates measuring instrument, Image instrument, projector and other precision testing equipments Our company has set up the complete quality system and has obtained ISO 13485, ISO 9001, and CE certificates. Our products a「e not only sold in china but also exported to Eu 「ope, South and East Asia, the Middle East and other overseas markets. Our staffs will adhere to the principle—"unity, integrity, innovation, honesty and pragmatic" and believe the faith—"fight and enterprise", to provide our customers excellent products and superior service. Canten 七 S 1. Esophagus stent 1.1 Covered esophagus stent------------一一一一一一一一一一一一一 1 1.2 Umbrella gastric fistula stent-------------------------- 2 1.3 Covered segmented esophagus st en t---------------- 3 3.2 Duodenal stent (OTWfTTS)------------------------------8 3.3 Colon Stent (OTWfTTS)----------------------------------------10 3.4 Rectum stent (OTWfTTS)--------------------------------------11 5. Customized stents Hunan Fude Technology Co., Ltd.

Open the catalog to page 1
Medical Niti Stent - 2

1. Esophagus stent 1.1 Covered esophagus stent Usage: Be used to dilate the esophagus、 cardia and anastomotic stoma stenosis and plug esophageal fistula Character istics: • The stent will engender a continued gentle radial tensile fo 『ce, acting on the inner wall of esophageal to expand the stenosis gradually and 「ebuilt the unobst「ucted passage • The covered structure effectively avoids the tumo「tissue ingrowth , 「educing the possibility of second stenosis • Lasso in the nea 「-end of the stent , easy to be 『ecycled. • Anti-refulx stents can be chosen to effectively restrain the gast...

Open the catalog to page 2
Medical Niti Stent - 3

Product show: • Lasso in the near-end of the stent, easy to be recycled • Anti-refulx stents can be chosen to effectively restrain the gas打oesophageal reflux disease . Product show: Introducer system sketch: 1.3 Covered segmented esophagus stent Specification of Introducer system (Pipe diameter F『 x effective working length mm) 24Fr x 700 24Fr x 700 Usage: Be used to dilate the esophagus、cardia and anastomotic stoma stenosis and Plug esophageal fistula Characteristics: • The stent will engender a continued gentle radial tensile fo 「ce,acling on the inner wall of esophageal to expand the...

Open the catalog to page 3
Medical Niti Stent - 4

Covering instruction of esophagus stent 2. Biliary stent 2.1 Conventional biliary stent Conventional covering pattern a. Uncovered b. Ma (partially covered) c. Mb(partially covered) d. Mc(fully cove「ed) Usage: Be used to ameliorate the pain caused by biliary stricture and obstruction We also can offer follow customized covering pattern service e. Md(partially covered) f. Me(partially covered) g. Mf(partially covered) h. Mg(partially covered) Characteristics: • Continued gentle radial tensile force.effectively expands the stenosis,reducing the patients' discomfort. • Imaging markers of the...

Open the catalog to page 4
Medical Niti Stent - 5

3. Intestinal stent 3.1 Pylorus stent Usage: Used fo「 malignant lesions caused by gastric outlet stenosis o「 obstruction, suitable for ministry of pyloric stenosis 卜 八 \ ` Specification table: Characteristics: • Continued gentle radial tensile fo 『ce,effectively expands the stenosis,reducing the patients' discomfort. • Imagi g marke 『s of the stents a『e clear visible under image equipment.Positioning is more accu「ate • Confo 「m to the pylorus of physiological anatomy port design 8.5F 「/9Frx 500 (PTCD introducer system) Product show: 8 5Fr/9Frx 500 (PTCD introducer system) 8 5Fr/9F 「x 1850...

Open the catalog to page 5
Medical Niti Stent - 6

• Imaging markers of the stents are clear visible unde「image equipment.Positioning is mo『e accurate. • Excellent flexibility, physiological bending conforms to the duodenum 3.3 Colon stent (OTWITTS) Usage: Used to treat colon narrow or obstruction caused by malignant lesions. Product show : Characteristics: • Continued gentle radial tensile force.effectively expands the stenosis,reduce the patients' discomfort • Imaging marke「s of the stents are clea『visible under image equipment.Positioning is more accurate. • Spherical structure design, reduces the stimulation, not easy to shift Product...

Open the catalog to page 6
Medical Niti Stent - 7

Specification table: 3.4 Rectum stent (OTW/TTS) Specification of Introducer system (Pipe diameter Fr x effective working length mm) I I 10Frx 2400 (TTS) PTFE pipe with s1ainless s1eel mesh grid inside 10Frx 2400 CTTS) PTFE pipe with stainless steel mesh grid inside 24Frx 1000 (OTW) 24Frx 1000 COTWJ Usage: Used to treat Rectum narrow o「 obstruction caused by malignant lesions Characteristics: • Continued gentle radial tensile force,effectively expands the stenosis,reducing the patients' discomfort. • Imaging markers of the stents are clea 「 visible under image equipment.Positioning 1s more...